Rapid Eye Multi-Media DVR System Administrator Guide
Document 800-02953V4 Rev A
209
03/10
Maintenance: changes to security,
time, storage, and so on
c
Use/misuse of Clear storage or Synchronize time by
operator or Multi SA.
Outputs: activate, output ports 1 to 8
Use/misuse of an onsite device by a View operator
(for example: remote locking of a gate).
Outputs: deactivate, output ports 1 to
8
Use/misuse of an onsite device by a View operator
(for example: unlocking a gate).
System: no video recording
Camera disabled by View operator.
System: reboot
Use/misuse of Reboot command.
System: failure, self-restart, reboot
Power failure or catastrophic failure of a unit.
System: No video recording
Failure of a unit’s video hardware.
System: time server, no synch, clock
drift, and so on
Failure of network or network’s time server.
System: disk failure
Warning of imminent failure of storage.
a
Some events are repeated in the table because their source can vary. For example, an alarm triggered by an
can also be triggered by rebooting a unit.
b
A Multi SA can set a Video lock event to only be logged rather than trigger an alarm.
c
Some configuration settings can be changed onsite, using LocalView. These changes are not logged, nor do they
trigger an alarm when the configuration event is set to do so.
Table 10-5
Event Reference, by Source and Tab (cont’d)
Source
Event in Maintenance (Except
Where Noted)
Possible Causes: an Alarm or Log Entry Could
Indicate...
Table 10-6
Event: Default Settings for Log and Alarm
Source
Event
Log
Alarm
Session: connect, reject and disconnect
off
off
Maintenance: configuration, security, system files,
synchronize time, clear storage, clear stream
All are logged; logging
cannot be disabled
off
Outputs: activate, deactivate
a
off
off
System: run-time failure, self-restart, reboot, no video
recording, time server unusable, no synchronization in 24
hours, excessive system clock drift, SMART disk failure
All are logged; logging
cannot be disabled
off
Inputs: activate, deactivate
off
off
Video: signal lock, signal unlock
off
off
ActivEye: event or alarm
off
off
Motion: Not on Event tab, on the Video tab
off
off
Tamper Detection: On the Video tab (not on the Event tab) off
off
User-defined: Not on Event tab, on the Serial Devices tab
off
off
a
Control Output 6 is unavailable as an event, due to its use by the Fault Relay. On a Multi-Media LT unit, the Fault
Relay does not make use of a control output.
Содержание Rapid Eye
Страница 2: ......
Страница 3: ...System Administrator Guide ...
Страница 22: ...22 ...
Страница 94: ...94 Video Feed Setup ...
Страница 114: ...114 Pan Tilt and Zoom PTZ Setup ...
Страница 258: ...258 Touring Many Sites ...
Страница 280: ...280 End User License Agreement ...
Страница 292: ...292 ...
Страница 293: ......