110
Pan, Tilt, and Zoom (PTZ) Setup
2.
On the Serial Devices tab, select the values shown in
Figure 6-15
Communication Settings for Intellibus on the Serial Devices Tab
Configuring an ACUIX Dome for PTZ Use
1.
Run a
2.
Click the Video tab.
3.
Click PTZ. For information about enabling and configuring a PTZ dome, see
.
4.
Select an ACUIX dome.
5.
In Port Attributes, enter values for Baud Rate, Stop Bits, Data Bits and Parity (as
shown in
).
6.
Do not use the same Camera Address for two ACUIX domes that share the same port.
7.
Repeat
for each ACUIX dome in your system.
Shortcut for selecting all of
the items listed in the table
Table 6-3
Intellibus Settings for ACUIX Domes
Communications
Value
Baud Rate
38400
Stop Bits
1
Data Bits
8
Parity Bits
None