Rapid Eye™ LT DVR Installation Guide
Document 800-07766V1 Rev A
55
02/11
Inputs for Sensors
Configuration Using View Software
1. Using View, start a Maintenance session for the Rapid Eye site. Wait until the
System
Operational
message appears. Click the
Events
tab. More tabs are displayed.
2. Click the
Inputs
tab.
3. Enter the name of an input in its Input box. You have the option of identifying inputs
that are not in use, such as input 7 and input 8 (see
4. You have the option of monitoring the activation of inputs and their deactivation by
selecting
Log
and
Alarm
, as needed.
5. By default, alarm/control inputs are configured as NO (normally open). Click
NC
(normally closed) or
EOL
(end-of-line), as needed.
Figure 5-4
Input Configuration During a Maintenance Session
Technical Notes
Inputs to a Multi-Media LT DVR Used by Hardware Devices
Honeywell recommends that installers report the connection of input devices to the
organization Multi-Media System Administrator, indicating if the devices are using
connections that are: normally open, normally closed or end-of-line.
Содержание Rapid Eye LT
Страница 1: ...Document 800 07766V1 Rev A 02 11 Installation Guide Rapid Eye LT Digital Video Recorder ...
Страница 2: ......
Страница 3: ...Installation Guide ...
Страница 14: ...14 Contents ...
Страница 16: ...16 Figures ...
Страница 18: ...18 Tables ...
Страница 44: ...44 Quick Test for Remote Video Figure 3 4 DVR Base IP Ports Remote Connection and Alarm Station ...
Страница 72: ...72 Site Information Checklists Point of Sale POS Hardware Type Name Model Data Text of Interest ...
Страница 76: ...76 ...
Страница 77: ......