User Guide 

___________________________________ 

P/N: H-D03-4001-000 
Rev M February 2018 

RAEGuard 2 PID 

Содержание RAEGuard 2 PID

Страница 1: ...___________________________________ User Guide ___________________________________ P N H D03 4001 000 Rev M February 2018 RAEGuard 2 PID ...

Страница 2: ...14 6 3 Electrical Wiring 15 6 4 Wiring Procedure 16 6 5 Earth Grounding Instructions 17 6 5 1 External Earth Grounding 17 6 5 2 Internal Earth Grounding 17 6 5 3 Finished Grounding Wires 18 6 6 Alarm Contact Setup 18 7 Display And User Interface 20 7 1 User Interface 20 7 2 Magnet Key 20 7 3 Using The Magnet Key 21 7 4 System Initialization 21 7 5 Reading Display 21 7 6 Instrument Status Display 2...

Страница 3: ...ode 28 9 2 Calibration 29 9 3 Measurement Advanced Mode 32 9 4 Alarm Setting 35 9 5 Monitor Setup 37 10 Calibration 43 10 1 Zero Calibration 44 10 2 Span Calibration 46 11 Alarm Signal Summary 48 12 Maintenance 50 13 DigiPID Sensor Module Replacement 50 14 Troubleshooting 52 SECTION 2 DigiPID User s Guide SAFETY INSTRUCTIONS 54 15 Read Before Operating 55 15 1 DigiPID Marking 56 15 2 Operation Are...

Страница 4: ...3 Maintenance And Calibration 68 21 4 Replacing the Lamp And Filter 68 22 Replacing The Sensor s Teflon UV Shield 70 23 Sensor Lamp Cleaning Replacement 73 23 1 Cleaning The PID Sensor 73 23 2 Cleaning The Lamp Housing Or Changing The Lamp 74 23 3 Cleaning The Instrument 75 23 4 Ordering Replacement Parts 75 23 5 Special Servicing Note 75 24 Electronic Waste Disposal 76 25 Appendix A Range Sensor ...

Страница 5: ...t are subject to change without notice These commodities technology or software were exported from the United States in accordance with the Export Administration Regulations Diversion contrary to U S law prohibited This product may contain or be derived from materials including software of third parties The third party materials may be subject to licenses notices restrictions and obligations impos...

Страница 6: ...RAEGuard 2 PID User s Guide 5 Section 1 RAEGuard 2 PID User s Guide ...

Страница 7: ...tor to be calibrated and operational parameters adjusted with the explosion proof enclosure in place In addition the PID module can be easily removed in hazardous locations for calibration or maintenance Key features Digital Smart Sensor Technology Three wires supports 4 20mA analog output Operates in flow through mode and can be used in most environments RS 485 digital communication in ModBus pro...

Страница 8: ... protection Electricity communications Fire protection Utilities Pulp and paper printing Storage Sewage disposal Food brewing Scientific research education homeland security Hazardous Location Classification ATEX II 2 1 G Ex db ia Ga IIC T4 Gb UL CSA Class I Div 1 Groups A B C D T4 IECEx TR CU Ex db ia Ga IIC T4 Gb 1Ex d ia Ga IIC T4 Gb X ...

Страница 9: ...tput 4 20mA Three level programmable alarm relays 30 VDC 2A RS 485 Supports Modbus IP Rating IP 65 Mechanical Interface 3 4 NPT Male Installation 2 pipe holding or wall mounting User Interface Three key magnetic bar adjustment Calibration Two or three points Environmental Parameters Temperature 20 C to 55 C 4 F to 131 F Humidity 0 to 95 relative humidity non condensing Pressure 90 to 110kPa Displa...

Страница 10: ... Life The Waste Electrical and Electronic Equipment WEEE directive 2012 19 EU is intended to promote recycling of electrical and electronic equipment and their components at end of life This symbol crossed out wheeled bin indicates separate collection of waste electrical and electronic equipment in the EU countries This product may contain one or more Nickel metal hydride NiMH Lithium ion or Alkal...

Страница 11: ... tested by exposing the sensor to a known concentration calibration gas before the instrument is used or put into service Prior to factory shipment the RAEGuard 2 PID is calibrated and tested However the user should calibrate the instrument before the first use Kit Accessories include RAEGuard 2 Magnet Key and User s Guide ...

Страница 12: ...ID can be easily installed and integrated with various control systems It is designed with flexible pipe holding wall mounting options and standard connection terminals 5 Physical Dimensions The physical dimensions are as shown 201mm 7 9 290 mm 11 4 133 mm 5 23 107mm 4 2 ...

Страница 13: ...ounting surface with the center of the holes 5 25 133mm apart Besides directly mounting the RAEGuard 2 PID to a wall it can be mounted on a pipe WARNING 1 To prevent ignition of hazardous atmospheres area must be free of flammable vapors and supply circuit must be disconnected before removing cover 2 For European application the installation must comply with the requirements of EN 60079 14 ...

Страница 14: ...ard 2 PID make sure the sensor is vertically oriented pointing straight down Also make sure the water trap filter is connected to the gas inlet labeled IN the longer of the two inlets Note Only operate the RAEGuard 2 PID in a non condensing environment Wall Pole ...

Страница 15: ...ousing body by rotating it counter clockwise As shipped one of the conduit holes is covered by the provided hex head plug The other conduit is for wire connections 3 Tilt the instrument assembly 90 4 Unlock the 24 pin connector on the ribbon cable 5 Lift the entire instrument assembly out of the housing 6 Unscrew the sensor by turning it counterclockwise Disassembled instrument 2 Pull off the reta...

Страница 16: ...d with the clip on the left side and tilt it over 4 Click the board into place 5 Screw on the sensor making sure not to block the gas inlet hole and connectors 6 Screw on the housing top 7 Screw down the fastening bolt 6 3 Electrical Wiring The detector connects to peripheral equipment via three terminal blocks These blocks accept 12AWG to 24AWG wire 0 2 to 4 0 mm2 Terminal blocks ...

Страница 17: ...s through the RAEGuard 2 PID s wire hole s and connect wires to the corresponding pin numbers of the terminal blocks Terminal Terminal Definition Terminal description No Block 1 Failure Alarm Contact ERR 1 Low Level Alarm Contact LOW 2 High Level Alarm Contact HIGH 3 Switch signal Common Contact COM 4 Block 2 4 20 mA Output OUT 5 Power Supply Negative GND 6 Power Supply Positive V 7 Block 3 RS485A...

Страница 18: ...Earth Grounding Use the same hardware as shown in the illustration of external earth grounding The wire should be no less than the size of the power lines Signal grounding can connect to a cable s shielding layer if shielded cable is used If a separate wire is used for grounding its cross section should be greater than that of the power line M4 flat washer M4 Split washer M4 Screw Wire Min 4 mm2 c...

Страница 19: ...e alarm contacts can drive external alarms such as a light or buzzer By default the three relays are set for normally open NO operation meaning that contact is closed when in alarm You can separately change each relay from normally open to normally closed NC operation by changing the position of the jumpers on the internal printed circuit board Alternate earth grounding point Internal earth ground...

Страница 20: ... either connecting the middle and top points or middle and bottom points Important Once the system is operational test the functionality of all three relays Note The relays may be disabled based on the sensor that is attached to the RAEGuard 2 PID Certain sensors such as the 1 1000 ppm DigiPID disable the correction factor library and relays of the RAEGuard 2 unit Users who require these functions...

Страница 21: ...atus LED an LCD display and three keys MODE and The three keys are operated by using the Magnet Key RAEGuard 2 PID user interface 7 2 Magnet Key The RAEGuard 2 PID has no external switches but instead uses the magnetic end of the RAEGuard Magnet Key p n 033 3032 000 to activate switches built into the unit Magnet SIDE VIEW TOP VIEW ...

Страница 22: ...s may be activated 7 4 System Initialization When the RAEGuard 2 PID s system power is turned on it initializes and a Honeywell logo appears on the display As the transmitter is warming up each component is checked The countdown timer appears on the screen for the warm up 7 5 Reading Display As the transmitter enters the Reading Display it automatically starts testing for errors and goes through a...

Страница 23: ...age or alarm condition gas concentration is displayed and LED flashes green If there is an error or alarm a corresponding message shows on the screen and the LED indicates different statuses Status External Alarm LED LCD Output Current Normal Green Reading Reading Low alarm Alarm Limit LOW Red flashing 2 Hz Reading Reading High alarm Alarm Limit HIGH Red flashing 3 Hz Reading Reading Over Range HI...

Страница 24: ...ng the details below UK Office Keison Products P O Box 2124 Chelmsford Essex CM1 3UP England Tel 44 0 330 088 0560 Fax 44 0 1245 808399 Email sales keison co uk Please note Product designs and specifications are subject to change without notice The user is responsible for determining the suitability of this product ...

Отзывы: