background image

RE252_Honeywell-Compat_PIN-Pad.doc 

Page 1 of 4 

28-Sep-12 

www.ResolutionProducts.com

 

 

 

 
Wireless  
Security  
Solutions 

 

 

RE252 Honeywell Compatible PINpad™ 

 

Features  

 

Secure, 4-digit Code to disarm 

 

1-button arming 

 

Red/Green LED arming feedback 

 

Small, yet comfortable keypad 

 

Mounts on wall via VHB® tape, or screws 

 

Secure for carrying in purse or mounting on car visor 

 

More securely replaces Honeywell 5878 6-button Wall Touchpad 

 

4-6 year battery life on CR2032 battery. 

 

Key Instructions 

 

Do NOT use this product for 2GIG panels.  Use the RE252

T.

 

 

PIN Code programming 

Default access code is “1234”.  
To change access code: 

1.

 

Enter current 4-digit access code. 

2.

 

Within 4 seconds, press and hold the “1” and “3” keys 
simultaneously. After 3 seconds, Red LED will be lit. 

3.

 

Enter new 4-digit access code. After successfully changing 
the code, the Green LED will be lit 

4.

 

Note new access code .  BAD GUY CANNOT RESET CODE. 
So it must be noted and remembered! 

 

Enrolling: 

 

1.

 

Refer to the Honeywell control unit installation manual. 

2.

 

Enroll exactly as you would a key fob. 
 

 

Specific Control Panel Programming follows here… 

 

Lynx Touch 5100: 

 
Programming   Keys   Add New 
 

System Programming… 

Key Type 

4 Button 

User 

Master 

Serial Number 

[press Stay key to enroll] 

Zone 

49 (example) 

Button Key 1 – Zn 49 

Arm Away 

Button Key 2 – Zn 50 

Disarm 

Button Key 3 – Zn 51 

Arm Stay 

Button Key 4 – Zn 52 

24 Hour Auxiliary 

 
To RF Learn: Press the PINpad STAY button twice, more than 5 seconds apart.   
Be at least 5 feet from panel. 

RE252_Honeywell-Compat_PIN-Pad.doc 

Page 2 of 4 

28-Sep-12 

www.ResolutionProducts.com

 

 

Lynx Touch 5100, continued… 

 

 

 
Lynx Plus 3000 & Vista: 

 
To RF Learn: Press each PINpad button (or PIN Code) twice, more than 5 
seconds apart.   
Be at least 5 feet from panel. 
Be sure to associate the Key with a User! 
 

 
You may also use WIRELESS KEY TEMPLATE 3. 
 

Operation  

 
 
 
 
 
 
 
 
 
 
 
 

2GIG Go! Panel

 

 
 
Use Resolution RE252

T

 2GIG-Compatible PINpad for 2GIG panels. 

 
Panic function will not work on 2GIG panel using this RE252 
Honeywell version. 

PINpad 
Button 

Lynx Touch 

Button Key 

Lynx Touch  

Loop 

Should be 

programmed to 

Away 

Button Key 1 

Loop 3 

ARM AWAY 

PIN Code 

Button Key 2 

Loop 2 

DISARM 

Stay 

Button Key 3 

Loop 4 

ARM STAY 

Stay + Away 

Button Key 4 

Loop 1 

24 Hour AUX 

PINpad 
Button 

Lynx Plus 

Zone Number 

Lynx Plus  

Zone Type 

Lynx Plus  

Input Type 

Lynx Plus  

Loop 

Away 

26  (example)  21  Arm-Away 

BR 

Loop 3 

PIN Code 

27 

22  Disarm 

BR 

Loop 2 

Stay 

28 

20  Arm-Stay 

BR 

Loop 4 

Stay + Away 

29 

07  24 Hr Aud 

BR 

Loop 1 

PINpad 
Button 

Panel Action 

LED 

Stay 

ARM STAY 

flashes double red 

Away 

ARM AWAY 

flashes double red twice 

PIN Code 

DISARM 

flashes double green 

Stay + Away 

PANIC ALARM 

flashes red 8 times 

Отзывы: