WIRING

LEGEND

HIGH VOLTAGE
12V LOW VOLTAGE

M29742

K7

K2

K3

P2

RED

THERMISTOR

(NOT ON ALL UNITS)

BLACK

GREEN

NEUTRAL

LINE

AUTO-

TRANSFORMER

SEE

DEFROST

DETAIL

WHITE

P4

BLUE

K4

K6

K1

P3

FAN O/P

T8

T7

P1

T3

T2

T9

T1

K5

DIRECT 

MOUNTED 

CAPACITOR

CAPACITOR

DEFROST DETAILS

PCB PLUG-IN

PLUG IN

CONNECTOR

BLACK

RED

ORANGE

ORANGE

1 2

P1

3 4

PIN 1–BLACK

PIN 2–ORANGE

PIN 3–RED

PIN 4–SPARE

RED

BLACK

BI-DIRECTIONAL

DAMPER MOTOR

PCB PLUG-IN

1 2

P1

3 4

PIN 1–RED

PIN 2–ORANGE

PIN 3–BLACK

PIN 4–SPARE

FAN

MOTOR

BROWN

BROW

N

GREEN

BLAC

K

WHITE

VNT

LOW
VNT

COM

RED

YEL

GRN

VNT HI

GF

R

GT

DSTAT

AUTO-TRANSFORMER DETAIL

PIN 1–BLUE

PIN 2–YELLOW

PIN 3–BROWN

PIN 4–RED

PIN 5–WHITE

PIN 6–BLACK

PIN 1–GREEN

PIN 2–GREEN

P5

AUTO

TRANSFORMER

4

5

6

1

2

3

1
2

P6

P5

PLUG-IN CONNECTOR

P6

Internal schematic for fresh air ventilation systems.

Fig. 19. 

HR150, 200; ER150, 200 Perfect Window™ Fresh Air Ventilation Systems   68-0171—12

15

Содержание PERFECT WINDOW ER150

Страница 1: ... round duct Non insulated 6 inch round duct Two 6 inch weather hoods Two 6 inch starter collars 1 2 inch I D drain hose Airflow balancing kit Foil tape HR150 200 or ER150 200 Perfect Window Fresh Air Ventilation System Owner s Manual Hanging straps T fitting E 2 drain spouts F1 VisionPRO IAQ control F2 TrueIAQ F3 Dehumidistat H8908 F4 Digital fan timer F5 W8150 ventilation control Not with C model...

Страница 2: ......

Страница 3: ...D MOUNTING PLUMBING WIRING APPENDICES DUCTING 1 GETTING STARTED Safety Definitions and Precautions 2 Application 3 Features 3 Planning the Installation 4 Sizing 5 Mounting Position and Location 6 Balancing Airflow 9 MOUNTING Installation 10 Suspended from Floor Joists 10 PLUMBING Installing Drain Line and P Trap 11 WIRING Heat Recovery Ventilator HRV and Energy Recovery Ventilator ERV Connections ...

Страница 4: ...ersonal injury Be sure ventilator is correctly grounded Confirm polarity of power line switched with safety disconnect switch when cleaning or servicing unit CAUTION Electrical Hazard Can cause equipment damage Disconnect HRV ERV from power source before connecting or disconnecting digital fan timer or other device to HRV ERV high speed override terminals Make sure you read and understand the foll...

Страница 5: ... speed fan Integral balancing dampers for quick installation Provides ventilation that helps contractors meet ASHRAE 62 Automatic economical built in frost control available for operation to design temperatures of 40 F 40 C HR150 and HR200 models have an easy to clean aluminum cross flow core ER150 and ER200 models have an advanced energy heat and moisture recovery fixed core Washable energy trans...

Страница 6: ... and 3 Planning the Installation Failure to comply with these requirements will result in voided warranty improper installation and service callbacks STALE AIR FROM INSIDE DEFROST PORT FRESH AIR TO INSIDE FRESH AIR FROM OUTSIDE STALE AIR TO OUTSIDE M29739 BALANCING DAMPER FILTERS Duct connections and airflow ER150B ER200B Fig 3 FILTERS 2 DRAIN M29853 MOTOR BLOWERS FRESH AIR FROM OUTSIDE DEFROST PO...

Страница 7: ...t 60 min x 35 ach 93 cfm 50 cfm intermittent or 20 cfm continuous capacity for bathrooms Example 50 cfm intermittent x 3 bathrooms 150 cfm 20 cfm continuous x 3 bathrooms 60 cfm 100 cfm intermittent or 25 cfm continuous capacity for kitchens Example 100 cfm intermittent x 1 kitchen 100 cfm 25 cfm continuous x 1 kitchen 25 cfm Option 1 Fresh Air Ventilation System provides continuous fresh air supp...

Страница 8: ...and ER200C do not have drain kits from the ventilator to a drain Use an existing electrical outlet with appropriate current rating or install one close to ventilator power cord Allow space for drain line by placing the ventilator at least 10 in 254 mm off the floor For access and removal of ventilator core allow at least 25 in 635 mm of open space in front of unit INSULATED FLEX DUCT COLLAR ON VEN...

Страница 9: ...t running and let the ventilator run whether the air handler is running or not see Fig 5 An independent installation is shown in Fig 7 NOTE When the home is occupied continuous operation of the ventilator is recommended When the furnace air handler operates fresh air is distributed through the heating air conditioning supply registers When the air handler is off fresh air is delivered through both...

Страница 10: ... SEPARATION REQUIRED 18 IN 0 46m ABOVE GRADE MINIMUM ADJUSTABLE FRESH AIR SUPPLY ADJUSTABLE DAMPERS FOR BALANCING AIR FLOW INTO AND OUT OF THE HOUSE FRESH AIR SUPPLY HOOD STALE AIR EXHAUST HOOD FLEXIBLE INSULATED DUCTING WITH A VAPOR BARRIER VENTILATOR EXHAUSTS FROM KITCHEN AND OR BATHROOMS OR OTHER CENTRAL LOCATIONS TO OUTDOORS VENTILATOR SUPPLIES OUTDOOR AIR DIRECTLY TO EACH BEDROOM TO EACH FLOO...

Страница 11: ...ons Digital Fan Timer The ventilator controls are compatible with the Digital Fan Timer If more than one timer is activated each runs independently with the ventilator running at high speed until all timers have timed out Up to eight timers can be installed in a system Moisture Control When a building is new there is excess moisture in the wood plaster cement and other construction materials When ...

Страница 12: ...ir Ventilation System Vibration isolation straps 4 Drain fittings 2 and T fitting 1 Literature package Except for the mounting hardware and drain fittings the ventilator is ready for installation Wiring drain connections and ducting are required to complete the installation Mounting Suspended from Floor Joists Mount the four vibration isolation straps provided to the side of the ventilator using t...

Страница 13: ...a P trap using the plastic T fitting provided Cut two lengths of 1 2 in ID hose and connect each 1 drain fitting to the end of the T fitting Position the center leg of the T fitting so it points upward 2 Connect the drain line to the center leg and tape it in 3 place to prevent any kinks See Fig 9 This creates a trap that will hold some condensation and prevent odors from being drawn up through th...

Страница 14: ...ator ERV Connections The connector is a three prong 120 Vac plug with ground If further wiring is required Honeywell recommends that a licensed electrician make all electrical connections It is very important that the unit be correctly grounded Digital Fan Timer M29806 HIGH SPEED STATUS LIGHTS SELECT BUTTON INITIATES HIGH SPEED VENTILATION FOR 20 40 OR 60 MINUTES YELLOW RED GREEN Digital fan timer...

Страница 15: ... VNT COM RED YEL GRN VNT HI GF R GT DSTAT M29845 JUMPER BETWEEN VNT COM AND RED JUMPER BETWEEN VNT COM AND VNT LOW 1 1 VISIONPRO IAQ VNT1 2 TERMINALS Off 10 20 30 40 50 60 W8150 AUX TERMINALS MECHANICAL TIMER DRY CONTACTS 2 TRUE IAQ VENT TERMINALS 2 6840 55 1215 76 In Out PM 20 40 60 TIMER FAN INTERLOCK CONTROL OPTIONS Wiring digital fan timer Fig 11 Wiring IAQ or ventilation control Fig 12 Wiring...

Страница 16: ...T DSTAT M29850 JUMPER BETWEEN VENT AND DEHUM JUMPER BETWEEN VNT COM AND RED LOW SPEED WILL OPERATE IF TrueIAQ IS CONFIGURED TO LOWER VENTILATION BASED ON OUTDOOR CONDITIONS SETUP NUMBER 115 2 1 2 2 6840 55 1215 76 In Out PM VENT VENT DEHUM DEHUM TrueIAQ 1 3 3 20 40 60 TIMER FAN INTERLOCK Wiring for fan interlock Fig 15 Wiring VisionPRO IAQ for ventilation and Fig 16 dehumidification Wiring TrueIAQ...

Страница 17: ...ANGE PIN 3 RED PIN 4 SPARE RED BLACK BI DIRECTIONAL DAMPER MOTOR PCB PLUG IN 1 2 P1 3 4 PIN 1 RED PIN 2 ORANGE PIN 3 BLACK PIN 4 SPARE FAN MOTOR B R O W N B R O W N GREEN BLACK WHITE VNT LOW VNT COM RED YEL GRN VNT HI GF R GT DSTAT AUTO TRANSFORMER DETAIL PIN 1 BLUE PIN 2 YELLOW PIN 3 BROWN PIN 4 RED PIN 5 WHITE PIN 6 BLACK PIN 1 GREEN PIN 2 GREEN P5 AUTO TRANSFORMER 4 5 6 1 2 3 1 2 P6 P5 PLUG IN ...

Страница 18: ...or accurate airflow measurements To avoid airflow turbulence and incorrect readings flow stations should be located at a distant point of at least five duct diameters for example 6 in 150 mm duct requires five diameters x 6 in 150 mm 30 in 76 cm from nearest valve or flow restriction This requirement applies to both stale air to exchanger duct and fresh air to house duct Before balancing make sure...

Страница 19: ... a year preferably at the beginning of each heating and cooling season Cleaning Filters and Core Open ventilator door by loosening draw latches on top of 1 unit and swinging door open For easier access remove door by moving it right to disengage hinges Carefully grip ends of core be careful not to damage 2 aluminum fins then pull evenly outward Core fits tightly but slides out of channels Once cor...

Страница 20: ...void blowing directly on occupants example over a sofa Outdoor temperature extremely cold Turn down ventilator supply speed Use a small duct heater 1 kW to temper the supply air Placement of furniture or closed doors is restricting movement of air in the home If supply air is ducted in furnace return run furnace fan continuously to distribute ventilation air comfortably Ventilator airflow can be i...

Страница 21: ...control set too low Set dehumidistat higher Blower speed of ventilator is too high Decrease ventilator blower speed Lifestyle of occupants Increase humidity with humidifiers Ventilator airflow can be incorrectly balanced Have a contractor balance ventilator airflow Ventilator and or ducts have frost buildup Ventilator airflow is incorrectly balanced NOTE Minimal frost build up is expected on cores...

Страница 22: ...8 001 50050728 001 Foam Prefilter Set of 2 5 209722 Included with Prefilter Included with Prefilter Clip for HRV Foam Prefilter 6 209715 209715 N A Defrost Damper Motor Bi directional 7 50048693 001 50048693 001 N A Drain Spouts and T Kit 8 50048694 001 50048694 001 50048694 001 Door latch double wide 9 50050832 001 50050832 001 50050832 001 Electronic Control Kit Control Board and Auto Transforme...

Страница 23: ...APPENDICES M29855 2 3 7 9 8 4 5 6 1 1 HR150 HR200 and ER150 ER200 exploded view of parts keyed to HR ER Parts List Fig 21 HR150 200 ER150 200 Perfect Window Fresh Air Ventilation Systems 68 0171 12 21 ...

Страница 24: ...C 200 cfm heat and moisture transferring core manual control and without frost control Color White Electrical Ratings Power Rating 120 Vac 60 Hz Amp Rating 1 4 A Consumption Mode Watts HR150 ER150 HR200 ER200 Low speed 63 70 High speed 173 182 Mounting Most models mount in conditioned space such as a basement utility room hallway or closet Can also be mounted in conditioned attic space NOTE ER150C...

Страница 25: ... cfm NET SUPPLY AIR FLOW HR200 VENTILATION PERFORMANCE HVI 25 50 75 100 125 150 175 20 40 60 80 100 120 140 160 180 200 220 240 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 STATIC PRESSURE IN W G AIR FLOW CFM MANUFACTURER S DATA 1 HIGH SPEED LOW SPEED 1 STALE AIR FROM INSIDE DEFROST PORT FRESH AIR TO INSIDE FRESH AIR FROM OUTSIDE STALE AIR TO OUTSIDE M29741A DEFROST DAMPER CONDENSATE DRAINS BALANCING DAMPER ...

Страница 26: ... 8 200 E S P EXTERNAL STATIC PRESSURE INCHES Pa CFM Ls ER200 VENTILATION PERFORMANCE NET SUPPLY AT LOW IN CFM L s AGAINST EXTERNAL STATIC PRESSURE 180 85 169 80 157 74 146 69 132 62 118 56 101 48 82 39 MANUFACTURER S DATA 1 HIGH SPEED LOW SPEED 220 200 180 160 140 120 100 80 60 40 20 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 AIR FLOW CFM STATIC PRESSURE IN W G 1 FILTERS 2 M29856 MOTOR BLOWERS ENERGY TRA...

Страница 27: ......

Страница 28: ... Inc 1985 Douglas Drive North Golden Valley MN 55422 Honeywell Limited Honeywell Limitée 35 Dynamic Drive Toronto Ontario M1V 4Z9 http yourhome honeywell com U S Registered Trademark 2010 Honeywell International Inc 68 0171 12 M S Rev 02 10 Printed in U S A ...

Отзывы: