Manual Switches
NR Series
Flat Base Sealed Rockers
128
Honeywell
1
Sensing and Control
1
1-800-537-6945 USA
1 F
1-815-235-6847 International
1
1-800-737-3360 Canada
NR 2-POSITION ORDER GUIDE
Circuits Made At:
No. of
Poles
Keyway
Position
Opposite
Keyway
UL Rating
Code
Electrical
Rating Code
Catalog
Listing
Rocker* Q-C
OFF
2-3
L191
1
31NT91-2
1
1-2
2-3
L191
1
31NR91-3
OFF**
2-3
L192
2
31NR91-4
1-2**
OFF
L192
2
31NR91-6
1-2**
2-3
L192
2
31NR91-8
OFF
2-3, 5-6
L191
3
32NR91-2
2
1-2, 4-5
2-3, 5-6
L191
3
32NR91-3
OFF**
2-3, 4-6
L192
4
32NR91-4
1-2, 4-5**
OFF
L192
4
32NR91-6
1-2, 4-5**
2-3, 4-6
L192
4
32NR91-8
NT 3-POSITION ORDER GUIDE
Circuits Made At:
No. of
Poles
Keyway
Position
Center
Position
Opposite
Keyway
UL Rating
Code
Electrical
Rating
Code
Catalog
Listing
Rocker* Q-C
1-2
OFF
2-3
L191
1
31NR91-1
1
1-2**
OFF
2-3
L192
2
31NR91-5
1-2**
OFF
2-3**
L192
2
31NR91-7
NONE***
OFF
2-3
L191
1
31NR91-21
NONE***
1-2
2-3
L191
1
31NR91-31
NONE***
1-2
2-3**
L192
2
31NR91-51
1-2**
OFF
NONE***
L192
2
31NR91-61
1-2, 4-5
OFF
2-3, 5-6
L191
3
32NR91-1
2
1-2, 4-5**
OFF
2-3, 5-6
L192
4
32NR91-5
1-2, 4-5**
OFF
2-3, 5-6**
L192
4
32NR91-7
NONE***
OFF
2-3, 5-6
L191
3
32NR91-21
NONE***
1-2, 4-5
2-3, 5-6
L191
3
32NR91-31
NONE***
1-2, 4-5
2-3, 5-6**
L192
4
32NR91-51
1-2, 4-5**
OFF
NONE***
L192
4
32NR91-61
1-2, 4-5
2-3, 4-5
2-3, 5-6
L191
3
32NR91-12
1-2, 4-5
1-2, 5-6
2-3, 5-6
L191
3
32NR91-10
1-2, 4-5**
1-2, 5-6
2-3, 5-6
L192
4
32NR91-50
1-2, 4-5**
1-2, 5-6
2-3, 5-6**
L192
4
32NR91-70
* Does not include rocker button. Order separately from chart.
** These positions are momentary. All others are maintained.
*** Toggle lever is blocked from these positions. Toggle becomes 2-position, with center being one extreme
position.
MATING CONNECTORS ORDER GUIDE
Description
Catalog Listing
2-pole connector
19PA168-NT
1-pole connector, same package size as 2-pole connector
19PA169-NT
ELECTRICAL RATING
L191: 15 amps, 125, 250, 277 VAC;
1
⁄
2
Hp,
125 VAC; 1 Hp, 250, 277 VAC; 5
amps, 125 VAC ‘‘L’’
L192: 10 amps, 125, 250, 277 VAC;
1
⁄
4
Hp,
125 VAC;
1
⁄
2
Hp, 250, 277 VAC; 3
amps, 125 VAC ‘‘L’’
TERMINAL CIRCUIT
IDENTIFICATION
Terminal identifications are referenced in
the order guides to indicate which circuits
are made in each toggle position (e.g.,
‘‘1-2’’
refers to circuit closure through ter-
minals
1
and
2
).
Top specify above-panel mount rock-
ers:
add
4
(after the ‘‘NR’’) to specify the
above panel version. Example: 31NR91-5
becomes 31NR
4
91-5.
ROCKER BUTTONS ORDER GUIDE
Rocker
Color
Catalog
Listing
White
12PA12-W
Red
12PA12-R
Yellow
12PA12-Y
Black
12PA12-BK
Green
12PA12-G
Blue
12PA12-BL