vides detailed information on detector spacing, placement,

zoning, wiring, and special applications.

Installation

The FST Series plug-in intelligent thermal detector uses a sep-

arate base to simplify installation, service, and maintenance.

Installation instructions are shipped with each detector.
Mount base (all base types) on an electrical backbox which is

at least 1.5" (3.81 cm) deep. Suitable boxes include:
• 4.0" (10.16 cm) square box.
• 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box.
• Single-gang box (except relay or isolator base).
• With B501BH-2 or B501BHT-2 base, use a 4.0" (10.16 cm)

square box.

• With B224RB or B224BI base, use a 3.5" (8.89 cm) or  4.0"

(10.16 cm) octagonal box, or a 4.0" (10.16 cm) square box.

NOTE: 1)

 Because of the inherent  supervision provided by the

SLC loop, end-of-line resistors are not required. Wiring “T-taps” or
branches are permitted for Style 4 (Class “B”) wiring. 

2)

 When

using relay or sounder bases, consult data sheet DN-2243 (ISO-X)
for device limitations between isolator modules and isolator bases.

Agency Listings and Approvals

These listings and approvals apply to the modules specified in

this document. In some cases, certain modules or applications

may not be listed by certain approval agencies, or listing may

be in process. 

Consult factory for latest listing status.

UL Listed:

 S747

ULC Listed:

 S6978

MEA Listed:

 383-02-E

• FM Approved

CSFM:

 7270-0028:196

BSMI:

 CI313066760025

CCCF:

 Certif. # 2004081801000018

U.S. Coast Guard:

 161.002/23/3 (AFP-200); 161.002/27/3

(AFP1010/AM2020); 161.002/42/1 (NFS-640)

Lloyd’s Register:

 03/60011

Product Line Information

“A”  suffix indicates ULC Listed model.

FST-851:

 Intelligent thermal detector. Must be mounted to one

of the bases listed below.

FST-851A:

 Same as FST-851 but with ULC Listing.

FST-851R:

 Intelligent thermal detector with rate-of-rise feature.

FST-851RA

: Same as FST-851R but with ULC Listing.

FST-851H:

 Intelligent high-temperature thermal detector.

FST-851HA:

 Same as FST-851H but with ULC Listing.

BASES: 

B710LP:

 Standard U.S. low-profile base

B710LPBP:

 Standard U.S. low-profile base, pkg. of 10.

B710LP:

 Standard U.S. low-profile base.

B710LP(A):

 Standard U.S. low-profile base.

B501BP:

 Standard European flangeless base, pkg. of 10.

B501:

 Standard European flangeless base.

B501(A):

 Standard European flangeless base, ULC Listing.

BH501BH-2: 

Sounder base, includes 

B501

base above.

BH501BHT-2:

 Same as B501BH-2, but includes temporal sounder.

BH501BHA:

 Sounder base, includes 

B501

base above 

BH501BHTA

: Same as BH501BHA, but includes temporal sounder.

B224BI(A):

 Intelligent isolator base. Isolates SLC from loop

shorts.

ACCESSORIES:

F110:

 Retrofit replacement flange for older style high profile

bases. Converts bases for use with FlashScan® detectors.

RA400Z(A):

 Remote LED annunciator. 3 – 32 VDC. Fits U.S.

single-gang electrical box. Supported by B710LPBP(A) and

B501(A) bases only.

SMK400E:

 Surface mounting kit provides for entry of surface

wiring conduit. For use with B501(A) base only.

RMK400:

 Recessed mounting kit. For use with B501(A) base

only.

SMB600:

 Surface mounting kit for use with B710LPBP(A).

BCK-200B:

 Black detector covers, box of 10.

M02-04-00:

 Test magnet.

M02-09-00: 

Test magnet with telescope stick.

XR2B:

 Detector removal tool. Allows installation and/or

removal of FlashScan® Series detector heads from base in

high ceiling installations.

T55-127-010: 

Detector removal tool without pole.

XP-4:

 Extension pole for XR2B. Comes in three 5-ft. sections.