Honeywell NORTH SUPERONE Series Скачать руководство пользователя страница 2

EN

 ENGLISH: INSTRUCTIONS FOR USE 

APPLICATIONS:

 Filtering half-masks classified 

FFP1, FFP2 or FFP3 against solid and liquid 

aerosols in concentrations up to Protection Fac-

tor x WEL (Workplace Exposure Limit): 4 x WEL: 

FFP1 class (low toxicity), 12 [10 in UK, FIN, D, I, 

S] x WEL: FFP2 class (average toxicity), 50 [20 

in FIN, S, UK & 30 D, I] x WEL: FFP3 class (high 

toxicity). « D » marked for passing the dolomite 

clogging test. « NR » (single-shift use) or « R » 

(Re-useable) marked according to the amended 

standard EN149:2001 +A1:2009

.

LIMITATIONS:

 Do NOT use this mask to enter or 

stay in an area where: • oxygen concentration is 

less than 17

% (oxygen-deficient atmospheres) 

• contaminants and/or their concentrations are 

unknown or immediately dangerous to life or

health • aerosol concentration exceeds levels

fixed by applicable health and safety regulations 

or Protection Factor x WEL • gases and/or

vapours  are  present.  Do  NOT  use  this  mask  in 

explosive atmospheres, except for references

supplied  with  a  Declaration  of  Conformity.  Do 

not use before receiving training.

CHECKING BEFORE USE: 

The user shall ensure 

that the mask is suitable for the intended appli-

cation before entering the contaminated area.

WEARING  AND  ADJUSTMENT:

  1  –  Cup  the 

mask  in  the  hand,  the  headbands  downward. 

2  –  Place  the  mask  under  the  chin.  Place  the 

lower headband around the neck, below the ears. 

3 – Holding the mask against the face with one 

hand, place the top headband above the ears, 

around the crown of the head. 4 – CHECK FOR 

LEAK-TIGHTNESS AS FOLLOWS: • place both 

hands over the mask and – exhale sharply for a 

mask  without  exhalation  valve  –  inhale  deeply 

for a mask with exhalation valve • if you feel air 

leaks around the edges, readjust the mask by 

increasing tension of the headbands (by tying 

a knot) • repeat the procedure until satisfactory 

face-fit  has  been  achieved.  N.B.:  requirements 

for leak-tightness are unlikely to be achieved if 

the respirator is worn against a beard or facial 

stubble.

USING:

  Taking  a  new  mask  from  its  box. 

1

 – Check the condition of the mask before use. 

2

 – Fit the mask and check leak-tightness before 

entering the contaminated area. 

3

 – Wear it for 

the whole duration of exposure to contaminants. 

4

  –  Discard  it  and  replace  with  a  new  one  if: 

• it is removed while in a contaminated area

• excessive clogging causes breathing difficulty 

or discomfort • it becomes damaged • for masks 

offering relief against nuisance odours, the

smell  becomes  detectable.  Do  not  alter  the 

mask. Leave the contaminated area if dizziness, 

irritation or other distress occurs.

WARNING: 

The mask shall not be used for more 

than one shift if it is for single-shift use (« NR »). 

Keep unused masks in their closed box and store 

in a non-contaminated area.

CLEANING:

 Applicable only on the re-useable 

masks (« R »). If the mask is to be used for more 

than one shift, the face seal must be cleaned 

with a wipe impregnated with a cleaning and 

disinfecting solution, without alcohol. Products 

comply with the European Parliament and 

Council Regulation (EU) 2016/425 for 

Personal Protective Equipment and subsequent 

amendments.  EU-type  examination  certificate 

and Quality assessment following module D by 

APAVE SUDEUROPE SAS - CS60193 - 13322 

MARSEILLE Cedex 16

 - FRANCE. Notified Body 

No. 

0082

.  EU-type  examination  certificate 

issued to: “HONEYWELL RESPIRATORY SAFETY 

PRODUCTS”. The EU declaration of

 conformity is 

available on the website https://doc.honeywell

-

safety.com/.

Sort out your waste by respecting the regulations 

in force.

EN 149:2001 + A1:2009

HONEYWELL RESPIRATORY SAFETY PRODUCTS

C.S. 55288 - 95958 ROISSY CDG Cedex - ZI PARIS NORD II - 33, rue des Vanesses  

VILLEPINTE - FRANCE

Phone: +33 (0)1 49 90 79 79

www.honeywellsafety.com

ТР ТС 

019/2011

 

Отзывы: