background image

Sensing and Internet of Things     

7

MICRO SWITCH NGC Series

ISSUE 7

  

 

32313117

Figure 9. Roller Plunger C & S 

Dimensions

Figure 8. Pin Plunger B & D 

Dimensions

20 [0.79]

30 [1.19]

FP ±0,5

NGC_B | FP 19,8 mm
NGC_D | FP 22,4 mm

Pin Plunger

40,8 

[1.6]

55,8 [2.2]

Ø 8

[Ø 0.31]

PT 2,1 [0.08]

2X Ø4,3 thru.

2X      Ø8    3,9

NGC_C | FP 30,3 mm

NGC_S | FP 32,85 mm

Roller Plunger

20 [0.79]

30 [1.19]

55,8 [2.2]

40,8 

[1.6]

FP ±0,5

Ø 12,7 x 4

[Ø 0.5 x 0.16]

PT 2,1 [0.08]

2X Ø4,3 thru.

2X      Ø8    3,9

Figure 10. Cross Roller Plunger L & T 

Dimensions

NGC_L | FP 30,3 mm

NGC_T | FP 32,85 mm

Cross Roller Plunger

20 [0.79]

30 [1.19]

55,8 [2.2]

40,8 

[1.6]

FP ±0,5

Ø 12,7

[Ø 0.5]

4 [0.16]

PT 2,1 [0.08]

2X Ø4,3 thru.

2X      Ø8    3,9

Figure 12. Panel-Mount Pin Plunger 

N Dimensions

Figure 11. Pin Plunger with Boot Seal 

M Dimensions

Figure 13. Panel-Mount Roller 

Plunger P Dimensions

NGC_M

Pin Plunger with Boot Seal

20 [0.79]

30 [1.19]

55,8 [2.2]

40,8 

[1.6]

32,3 [1.27]

Ø 6,7

[Ø 0.26]

PT 2,1 [0.08]

2X Ø4,3 thru.

2X      Ø8    3,9

NGC_N

Panel-Mount Pin Plunger

20 [0.79]

30 [1.19]

36,5 [1.44]

M12 x 1

Ø 8

[Ø 0.31]

7,0 [0.28] max.

PT 2,1 [0.08]

2X Ø4,3 thru.

2X      Ø8    3,9

NGC_P

Panel-Mount Roller Plunger

20 [0.79]

30 [1.19]

40,8 

[1.6]

55,8 [2.2]

M12 x 1

47,5 [1.87]

PT 2,1 [0.08]

Ø 12,7 x 4

[Ø 0.5 x 0.16]

2X Ø4,3 thru.

2X      Ø8    3,9

7,0 [0.28] 

max.

Figure 15. Panel-Mount Pin Plunger 

With Boot Seal R Dimensions

Figure 14. Panel-Mount Cross Roller 

Plunger Q Dimensions

NGC_Q

Panel-Mount Cross Roller Plunger

20 [0.79]

30 [1.19]

40,8 

[1.6]

55,8 [2.2]

Ø 12,7

[Ø 0.5]

M12 x 1

4 [0.16]

PT 2,1 [0.08]

47,5 [1.87]

2X Ø4,3 thru.

2X      Ø8    3,9

7,0 [0.28] max.

NGC_R

Panel-Mount Pin Plunger

with Boot Seal

20 [0.79]

30 [1.19]

40,8 

[1.6]

55,8 [2.2]

47,5 [1.87]

M12 x 1

PT 2,1 [0.08]

Ø 6,7

[Ø 0.26]

2X Ø4,3 thru.

2X      Ø8    3,9

7,0 [0.28] max.

Figure 16. Top Roller Lever Arm  

J Dimensions

NGC_J

Top Roller Lever Arm

20 [0.79]

30 [1.19]

40,8 

[1.6]

55,8 [2.2]

6,8

[0.265]

2X      Ø8    3,9

Operating Position

2X Ø4,3 thru.

Ø 14 x 5

32

[1.26]

Содержание NGC Series

Страница 1: ...st be checked and tested at regular intervals only by a suitably qualified person m ATTENTION BLESSURES CORPORELLES NE PAS UTILISER ces produits en tant que dispositifs d arrêt d urgence ou de sécurité ni dans aucune autre application où la défaillance du produit pourrait entraîner des blessures corporelles L inobservation de ces instructions peut entraîner la mort ou de graves blessures ENTRETIEN...

Страница 2: ...änderung der Schaltbetätigungs Kenndaten müssen unbedingt bereits im Anfangsstadium erkannt und vom End nutzer behoben werden um die Sicherheit des Bedienenden zu gewährleisten Durch regelmäßige Wartung des Schalters und Auswechseln in angemessenen Zeitabständen werden Störungen infolge von Abnutzung vermieden Das Wartungsintervall richtet sich nach der Art der Maschine und liegt in der Verantwort...

Страница 3: ...lution Verschmutzungsgrad 3 III Operating temperature Température de foncionnment Betriebstamperatur 25 C to 75 C 13 F to 167 F for extended operating temperature options see Table 3 Mechanical life Durée de vie mécanique Mechanische Lebensdauer 1NC 1NO 5 M cycles min at 120 CPM 2NC 2NO 5 M cycles min at 60 CPM Electrical life Durée de vie électrique Elektrisches Lebensdauer 1 A 110 Vdc 500 000 cy...

Страница 4: ...nel mount roller plunger R Panel mount pin plunger w boot seal N Panel mount pin plunger C B A Side exit right Bottom exit Side exit left A Connection 05 02 00 No cable Internal connector 0 25 m 0 82 ft 0 5 m 1 64 ft 02 Cable Length 10 07 0 7 m 2 3 ft 1 0 m 3 28 ft 20 15 1 5 m 4 92 ft 2 0 m 6 56 ft 30 3 0 m 9 84 ft 4 0 m 13 12 ft 50 5 0 m 16 4 ft 40 Connector Cable Exiting Housing D B A Standard c...

Страница 5: ... 0 71 PT PT FP 7 0 28 19 9 0 78 67 4 2 65 55 8 2 2 40 8 1 6 20 0 79 30 1 19 Type A6A A6B Side Rotary Short 16 7 0 66 52 2 05 Ø 18 Ø 0 71 PT PT FP 7 0 28 67 4 2 65 55 8 2 2 40 8 1 6 20 0 79 30 1 19 Type A2A A2B Side Rotary with Adjustable Length Roller Lever 16 7 0 66 29 1 14 51 2 00 min 103 4 05 max Figure 7 Side Rotary A2C A2D Dimensions Figure 6 Side Rotary A6C A6D Dimensions 20 0 79 30 1 19 Typ...

Страница 6: ...rt information The following example relates to a unit which has a snap action basic and which has a roller pin plunger actuator Follow the black arrows and the black strip on the chart The black strip indicates that there is a circuit between the terminals whose numbers are shown on the left and when white there is no circuit Look at Figures A and B as examples Actuator type used for test is the ...

Страница 7: ... with Boot Seal 20 0 79 30 1 19 55 8 2 2 40 8 1 6 32 3 1 27 Ø 6 7 Ø 0 26 PT 2 1 0 08 2X Ø4 3 thru 2X Ø8 3 9 NGC_N Panel Mount Pin Plunger 20 0 79 30 1 19 36 5 1 44 M12 x 1 Ø 8 Ø 0 31 7 0 0 28 max PT 2 1 0 08 2X Ø4 3 thru 2X Ø8 3 9 NGC_P Panel Mount Roller Plunger 20 0 79 30 1 19 40 8 1 6 55 8 2 2 M12 x 1 47 5 1 87 PT 2 1 0 08 Ø 12 7 x 4 Ø 0 5 x 0 16 2X Ø4 3 thru 2X Ø8 3 9 7 0 0 28 max Figure 15 Pa...

Страница 8: ...L M N P Q R S T B NGCM X01 B C D L M N P Q R S T D NGCM X07 B C D L M N P Q R S T A 07 NGCM X07 B C D L M N P Q R S T B NGCM X07 B C D L M N P Q R S T D NGCM X01 B C D L M N P Q R S T P 01 Zb 22 2 1 4 14 21 1 3 13 2 3 4 5 Green Yellow NGCP X07 B C D L M N P Q R S T P 07 NGCP X24 B C D L M N P Q R S T A 24 White Violet Black Red Blue Gray Brown Orange 2 Zb White Violet Gray Black Orange Blue DT Con...

Страница 9: ... N 07 NGCM X01 J A 01 Zb Blue 13 Green Yellow Brown 14 22 Black 21 Black White NGCM X01 J B NGCM X01 J D NGCM X07 J A 07 NGCM X07 J B NGCM X07 J D NGCM X01 J P 01 Zb 22 2 1 4 14 21 1 3 13 2 3 4 5 Green Yellow NGCP X07 J P 07 NGCP X24 J A 24 White Violet Black Red Blue Gray Brown Orange 2 Zb White Violet Gray Black Orange Blue DT Contact Closed Contact Open Positive Opening Brown Red White Violet G...

Страница 10: ...nt la période de couverture la société Honeywell réparera ou remplacera selon son choix et gratuitement ceux qu elle estimera à sa seule discrétion défectueux Ce qui précède constitue le seul recours de l acheteur et se substitue à toutes autres garan ties explicites ou implicites y compris celles relatives à la commercialisation ou la compatibilité avec une application particulière Honeywell ne p...