Honeywell MM Series Скачать руководство пользователя страница 2

EN

DO NOT operate the unit with a damaged plug or loose wall 
outlet. If the supply cord is damaged, it must be replaced 
by the manufacturer, its service agent or similarly qualified 
persons in order to avoid a hazard.
DO NOT cover the air intake and exhaust when in use.
DO NOT place objects on or sit on the unit.
Always turn off and unplug the unit when cleaning or 
servicing.
DO NOT use the appliance if it is damaged.
If service is needed contact an authorized service agent.
Unplug the unit when stored or not in use.
DO NOT pull or carry the appliance by the power cord.
DO NOT pinch the wire in the door and DO NOT pull it along 
edges or sharp corners.
DO NOT run the power cord under carpeting and rugs.
Use caution to prevent tripping on cord.
DO NOT use the device in the following cases:
- Near a fire source
- In areas where gasoline, paint or other flammable  
   goods are stored
- In an area where the water can be projected
DO NOT touch the plug or the device with wet hands.
Basic safety precautions should always be followed when 
using electrical appliances.

SAFETY

READ AND SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS. READ CAREFULLY AND 
KEEP FOR FUTURE REFERENCE. IN CASE THERE IS ANY 
INCONSISTENCY OR CONFLICT BETWEEN THE ENGLISH 
VERSION AND ANY OTHER LANGUAGE VERSION OF THE 
CONTENT OF THIS MATERIAL, THE ENGLISH VERSION 
SHALL PREVAIL.

WARNING:

Содержание MM Series

Страница 1: ...ea y guarde estas instrucciones antes de usar la unidad ES Customer Support Assistance Au Client Servicio de atencion a clientes USA EE UU 1 800 474 2147 CANADA CANADÁ 1 888 209 0999 www jmatek com Email usinfo jmatek com Canada Customer Support service available for models sold in Canada only Le Service Client Canadien est disponible uniquement pour les modèles vendus sur le territoire Canadien S...

Страница 2: ...OT pinch the wire in the door and DO NOT pull it along edges or sharp corners DO NOT run the power cord under carpeting and rugs Use caution to prevent tripping on cord DO NOT use the device in the following cases Near a fire source In areas where gasoline paint or other flammable goods are stored In an area where the water can be projected DO NOT touch the plug or the device with wet hands Basic ...

Страница 3: ...erning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Never insert your fingers or rods into the air outlet Take special care to warn children of these dangers The manufacturer is not liable for injury caused to persons or property damage due to non com...

Страница 4: ...ution Auto Evaporation System The unit automatically evaporates the condensate through the exhaust hose There is no need to empty the drainage tank except in very humid conditions Read and follow the instructions carefully To ensure optimal efficiency of the product keep doors and windows closed when it is used as an air conditioner or dehumidifier If the product is being used with the fan functio...

Страница 5: ...ceptor 9 Remote Control 2 Air Outlet 10 Lower Drain Plug with Plastic Cap Air Conditioning Mode 3 Handle 11 Upper Drain Plug De humidifier Mode 4 Casters 12 Air Inlet Filter 5 Upper Dust Filter 13 Lower Dust Filter 6 Upper Grill 14 Lower Grill 7 Exhaust Hose Connector 8 Power Supply Cord ...

Страница 6: ...7 inches each allowing you to install to windows and balcony doors of different heights or width Adjustable Knobs 19 7 50cm 1 part 1 Window Bracket Kit 1 Set 4 Hole Cover 1 Piece 2 Window Bracket Panel Adapter 1 Piece 5 Exhaust Hose 1 Piece 3 Exhaust Hose Connector 1 Piece 50cm 19 7 to 97cm 38 2 2 parts 1 2m 47 2 3 parts 2 4 x1 To install the window bracket to the window frame you need to adjust t...

Страница 7: ...e opposite end of the exhaust hose Ensure that all connections are tight and installed properly 5 Connect the window bracket to the window 6 The Portable Air Conditioner is now ready to use Note After setting the window bracket to the size of your window please remove it from the window and follow the instructions below Exhaust Hose Dia 5 12 7cm Length 12 to 47 30cm to 120cm ...

Страница 8: ...f Make sure the back of the unit is at least 50 cm 20 inches away from the wall Do not place the unit in front of curtains or drapes as this could obstruct the airflow WARNING Any warranties included with this product will be voided if an extra extension hose is added to the originally provided installation kit or if the installation is performed differently than the manufacturer s instructions wi...

Страница 9: ...idified as it passes through the unit without being in full cooling mode If room temperature is higher than 25 C 77 F fan speed can be adjusted otherwise fan speed is preset to LOW Note If the unit will be used mainly as a dehumidifier do not connect the exhaust hose Continuous drainage is then necessary refer to Continuous Draining for Dehumidifier Mode Fan Mode For air circulation without air co...

Страница 10: ... default display is setting temperature In cooling mode when or button is pressed the set temperature is displayed and may be adjusted After 10 seconds the display will revert back to room temperature Temperature is only adjustable in cool mode The time is adjustable between 1 24 hours Note By pressing both or buttons at the same time the display will toggle between Celsius C and Fahrenheit F When...

Страница 11: ... device complies with part 15 of the FCC Rules Operation is subject to following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These li...

Страница 12: ... the Window Bracket Window Bracket Panel Adapter and Exhaust Hose Connector It is recommended to store the Window Kit parts in a bag together with the Remote Control and placing them together with the air conditioner unit If needed you can clean the Window Kit with a damp cloth and water before storing Make sure all parts of the Window Kit are dry before storage EN Switch off and unplug the air co...

Страница 13: ...er source Remove the upper lower rubber drain plug Some residual water may spill so please have a pan to collect the water See diagram Connect the drain connector to a hose or standard garden hose not included The water can be continuously drained through the drain tube into a floor drain or bucket Replace the drain plug You can now turn on the unit 1 2 3 4 5 6 Continuous Draining for Dehumidifier...

Страница 14: ...SA Canada Mexico only Runs a short while only The thermostat temperature setting is too close to room temperature Lower the set temperature Air outlet is blocked Make sure the exhaust hose is properly connected There are tight bends in the air exhaust hose Connect exhaust hose as per instructions on page 4 In Heat Mode the unit keeps switching off frequently The room is too humid Water Tank needs ...

Страница 15: ... Installation section Temperature setting is too high Reduce temperature setting on control panel Air outlet or intake is blocked Remove blockage Room exceeds recommended size Move unit to smaller room Large size or number of windows are decreasing cooling effectiveness Cover windows with curtains or blinds Will not run and Power button is blinking water full indicator Excess water condensation in...

Страница 16: ... Heating function not activated yet The ambient temperature is too high Check that the Heating function has been activated will be illuminated when the Heater is switched ON Heating is activated only when the ambient temperature is below 25 C 77 F Switch on the Heating function when the ambient temperature reaches below 25 C 77 F EN Applicable for models with Heating feature only ...

Страница 17: ... ERROR CODE GUIDE ERROR CODE ERROR POSSIBLE CAUSE E1 Indoor temperature sensor failure open circuit or short circuit E3 Evaporator temperature sensor failure open circuit or short circuit P1 Water Full alarm ...

Страница 18: ...ine 2017 JMATEK Limited Tous droits réservés La marque déposée Honeywell est utilisée en vertu d une licence de Honeywell International inc Honeywell International inc ne fait aucune déclaration et ne donne aucune garantie à l égard de ce produit Ce produit est fabriqué par Airtek Int l Corp ltée une filiale de JMATEK Limited FR Hecho en China 2017 JMATEK Limited Todos los derechos reservados La m...