EGPWS LINE MAINTENANCE MANUAL
CAGE CODE: 97896
SCALE: NONE SIZE: A
DWG NO.: 060-4199-180
REV: G
SHEET 58 of 68
4. Align the Configuration Module housing to the P2 connector ensuring that wires are properly contained within
the connector assembly.
5. Install the two screws securing the Configuration Module to the P2 connector.
6. Connect the P2 connector assembly to the EGPWC.
7. Provide power to EGPWC and all required sensors and subsystems.
8. Program the Configuration Module per the instructions in Section 4.4 and any appropriate aircraft drawings that
define the proper values to use.
9. Perform EGPWS Level 1, 2, and 3 Self-Test per Section 3.3 to 3.5 to verify system function and proper
configuration per aircraft drawings.
6.3 DISPLAY SWITCHING RELAYS (IF INSTALLED)
Refer to appropriate EGPWS aircraft wiring and mechanical drawings.
6.3.1 REMOVAL
1. Remove power to the EGPWC.
2. Remove power to the Weather Radar system.
3. Remove power to the EGPWS/Weather Radar display switching relays.
4. Access and remove the display switching relay(s) using standard maintenance practices.
6.3.2 INSTALLATION
1. Ensure that EGPWC, Weather Radar, and display switching relay power is removed.
2. Mount relay(s) and secure.
3. Provide power to the EGPWC and all required sensors and subsystems.
4. Provide power to the Weather Radar system.
5. Provide power to the display switching relays.
6. Perform a Level 1 Self-Test per Section 3.3 to verify relay operation.
7 ADJUSTMENT/TEST
7.1 ADJUSTMENT
The EGPWS does not require any adjustments.
7.2 TEST
Line maintenance testing for the EGPWS consists of functional verification of the EGPWC and associated
interfaces. For EGPWC functional verification, see the Fault Isolation Section 3. Associated interfaces are verified
through EGPWS ground tests as described in the following section.
7.2.1 EGPWS GROUND TESTS
All EGPWS Ground Tests are developed by the installer to meet aircraft specific interfaces. Examples of Ground
Test are available from Honeywell via the EGPWS website. To obtain a copy of a sample Ground Test Procedure,
please visit
www.egpws.com
, select the Installation Information page, then select the Ground and Flight Test
Procedures sub-page.