background image

 

Once the 4 screws are removed the Processor board can be pulled away from the Mother board. The board can be 
folded down to rest on the bench with all cables still attached.  
 
 

Fig 3 QX Recorder 

Fig 4 SX Recorder 

 
 
 
 
 
 
 

Inverter 
Connector 

Display 
Connector 

Touch screen 
Connector 

 

QX Recorder

  

ƒ

 

Carefully remove the inverter connector by gently pulling upwards. Pull on the connector body, not on the 
cables. 

ƒ

 

Carefully remove the touch screen connector by gently pulling upwards. Pull on the connector body, not on the 
cables. 

ƒ

 

To remove the display connector the top of the connector is pulled up to release the flat cable. 

ƒ

 

The Processor board should now be free and can be removed. 

 

SX Recorder 

ƒ

 

Carefully remove all the connectors by gently pulling upwards. Pull on the connector body, not on the cables.  

ƒ

 

The Processor board should now be free and can be removed. 

 
Remove the internal compact flash card and if necessary fit to the new Processor board. 
Remove the user accessible compact flash card if fitted and replace in the new board. 
 
 
 
 
 
 
 

43-TV-33-58 i

 

ss.1   GLO   June 06  UK 

 

Содержание Minitrend QX Series

Страница 1: ...VOLTAGES Disconnect all power to the recorder before removing the case and attempting any maintenance procedures SAFETY TESTS Upon completion of service procedures detailed in this manual two basic safety tests should be performed in order to ensure continued safe operation of the instrument Earth Resistance 25 VDC applied between case and protective earth bonding resistance should be 0 1 Ohm Insu...

Страница 2: ...unting clamp screws slide the clamp towards the rear of the recorder and remove the clamps and the recorder Removing the Case and Rear Panel To fit a new Processor board the case and back panel must be removed The case and back panel can be removed as a single assembly Remove the 2 screws on each side of the case as shown in the figures below Fig1 QX M3 x 6mm Fig 2 SX M4 x 8mm 43 TV 33 58 iss 1 GL...

Страница 3: ...urface is suitable and that the front of the recorder will not get scratched Remove the 4 screws M3x6mm that secure the processor board to the chassis The figures below show the position of these screws Fig 3 QX Fig 4 SX Fig 3 QX Recorder Remove 4 screws 43 TV 33 58 iss 1 GLO June 06 UK 3 Fig 4 SX Recorder Remove 4 screws ...

Страница 4: ...een connector by gently pulling upwards Pull on the connector body not on the cables To remove the display connector the top of the connector is pulled up to release the flat cable The Processor board should now be free and can be removed SX Recorder Carefully remove all the connectors by gently pulling upwards Pull on the connector body not on the cables The Processor board should now be free and...

Страница 5: ...r The SX recorder display cable is simply pushed on but must be correctly aligned Fold the processor board up being careful not to trap any of the cables and align the processor board connector with the mother board Push the processor board on and ensure the connectors are fully mated Re fit the four M3 screws Re fit the case and back panel assembly Fit the case by carefully sliding it on from the...