background image

User Instructions - English

14

7.0 Zinc Plated Swivel Anchors

10,000 lbf/44kN 

Model Numbers RACSWY100N (Swivel only), RACSWY100S (Swivel anchor with steel mount-
ing hardware), and RACSWY100C (Swivel anchor with concrete mounting hardware),

 

RAC-

SWY1SBA (Steel mounting hardware only), RACSWY1CSA (Concrete mounting hardware),  

RACSWP100N-KIT (Weld kit) and RACSWX100N (Steel back plate).

Warnings and Limitations

• 

Use only with Honeywell-approved personal fall arrest or restraint systems. The anchorage 

must have the strength capable of supporting a static load, applied in the directions 

permitted by the system, of at least 10,000-lbf (22kN) in the absence of certification.

• 

The anchorage connector may be pulled in any direction shown in the LOADING 

CONDITIONS DIAGRAM (Pg. 15)

8.0”ø 

(203.2mm)  

180°  

360°  

5.5” 

(139.7mm)  

2.25”ø 

(57.15mm)  

3.0” 

(76.2mm)  

1.0” 

(25.4mm)  

Tensile Strength (UTS):

 10,000-lbf (44kN) 

Working Load (WLL): 

2,000 lbs (907kg)

Maximum Capacity:

 One worker, 310 lbs (140 kg) 

Weight:

 1.2 lbs (544.3g) 

Regulatory Compliance

ANSI Z359.1-2007, ANSI Z359.7-2011, OSHA 1910.66,

 

1926.502

Содержание Miller RACDNC-TOOL

Страница 1: ......

Страница 2: ...s 3 4 2 0 Purpose 4 3 0 Warnings and Limitations 4 5 3 1 Compatibility Limitations 4 0 Drop Through Anchor 6 5 0 Zinc Plated Swivel Anchor 7 6 0 Stainless Steel Swivel Anchors 10 7 0 Zinc Plated Swivel Anchors 14 8 0 Hybrid Concrete Anchor 19 Product Labels 48 Inspection and Maintenance Log 51 1 0 Requisitos Generales Advertencias y Limitaciones 27 28 2 0 Compatibilidad del Sistema 28 2 1 Grupos d...

Страница 3: ...rs must reference the regulations governing occupational safety as well as applicable ANSI or CSA standards Please refer to product labeling for information on specific OSHA regulations and ANSI and CSA standards met by product Proper precautions should always be taken to remove any obstructions debris material or other recognized hazards from the work area that could cause injuries or interfere w...

Страница 4: ...for correct use and care of this product All users of this equipment must understand the instructions operation limitations and consequences of improper use of this equipment and be properly trained prior to use per OSHA 29 CFR 1910 66 and 1926 503 or applicable local standards Misuse or failure to follow warnings and instructions may result in serious personal injury or death 1 The user shall be ...

Страница 5: ...ified anchorages When more than one personal fall arrest system is attached to an anchorage the above anchorage strengths must be multiplied by the number of personal fall arrest systems attached to the anchorage 3 1 Compatibility Limitations COMPATIBILITY LIMITATIONS All anchorage connectors must only be coupled to compatible connectors OSHA 29 CFR 1926 502 prohibits snaphooks from being engaged ...

Страница 6: ... on a horizontal surface that is above the users location 2 Locate or create a through hole in concrete steel or metal grating capable of withstanding a 5 000 lbf Static load or meeting OSHA 1926 502 requirements for a safety factor of two Reference figure 1 A below for dimentional requirements 3 Place cable through the hole from top side The label on plate should be facing up Plate must rest flat...

Страница 7: ...ns permitted by the system of at least 5 000 lbf 22kN in the absence of certification The anchorage connector may be pulled in any direction shown in the LOADING CONDITIONS DIAGRAM pg 9 Use a proper drill bit for concrete SDS drill bit Drill a 5 8 16mm hole no less than 4 102mm deep an 8 203mm away from any edge Hole must be straight perpendicular to surface Hole must be free of debris Concrete st...

Страница 8: ...User Instructions English 8 7 178mm min drill 5 8 16mm Ø 8 203mm min from any edge Torque 60ft lbs 4 min 102mm 180 360 8 0 ø 203 2mm 2 25 ø 57 15mm 5 5 139 7mm 3 0 76 2mm ...

Страница 9: ...ITIONS DIAGRAM LOAD ACCEPTABLE ACCEPTABLE IMPROPER ACCEPTABLE LOAD LOAD LOAD Torque 45 ft lbs 61 Nm 1 2 13 Lock Nut 1 2 Lock Washer 1 2 13 x 4 Hex Bolt drill 1 2 12 7mm Ø 1 4 6mm min 3 76mm min from any edge Use tapered washer STEEL MOUNTING ...

Страница 10: ...l fall arrest or restraint systems The anchorage must have the strength capable of supporting a static load applied in the directions permitted by the system of at least 5 000 lbf 22kN in the absence of certification The anchorage connector may be pulled in any direction shown in the LOADING CONDITIONS DIAGRAM below 8 0 ø 203 2mm 180 360 5 5 139 7mm 2 25 ø 57 15mm 3 0 76 2mm 1 0 25 4mm LOAD LOAD L...

Страница 11: ... be at least 3000psi 20 7MPa and no less than 7 178mm thick Drop expansion sleeve into hole Use the Setting Tool by placing it in the hole resting on the expansion sleeve Tap tool until the blue inner sleeve is at the bottom of the expansion sleeve Now place swivel over the hole and install the bolt provided drill 3 4 19mm Ø 9 229mm min from any edge 7 178mm min TAP Torque Range 30 40 ft lbs 22 30...

Страница 12: ...olt no shorter than 4 100mm with a locking nut and washer must be used Swivel anchor must be flush with steel surface A 16mm bolt may be used in place of a 5 8 11 for metric applications 1 4 6mm min WELD ON MOUNTING 316 Stainless Steel 5 8 11 x 1 3 4 Bolt Weld Welding procedure must be approved by a Engineer or other qualified person to be compatible with any and all structural operational charact...

Страница 13: ...TENTS PART NUMBER RACSWS1SBA 316 Steel Mounting Hardware Kit RACSWS100S 316 Swivel with Steel Mounting kit RACSWS1DNC 316 Concrete Hardware Kit RACSWS100C 316 Swivel with Concrete Mounting Kit RACSWP100N 316KIT Weld on Mounting Kit RACDNC TOOL Concrete Anchor Tool ...

Страница 14: ...proved personal fall arrest or restraint systems The anchorage must have the strength capable of supporting a static load applied in the directions permitted by the system of at least 10 000 lbf 22kN in the absence of certification The anchorage connector may be pulled in any direction shown in the LOADING CONDITIONS DIAGRAM Pg 15 8 0 ø 203 2mm 180 360 5 5 139 7mm 2 25 ø 57 15mm 3 0 76 2mm 1 0 25 ...

Страница 15: ...Range 75 90 ft lbs 100 120 Nm 1 4 6mm min drill 5 8 16mm Ø Use tapered washer with I beams that have tapered flanges 3 76mm min from any edge 5 8 11 For steel applications a grade 5 8 or equivalent bolt no shorter than 4 100mm with a locking nut and washer must be used Swivel anchor must be flush with steel surface A 16mm bolt may be used in place of a 5 8 11 for metric applications ...

Страница 16: ...be at least 3000psi 20 7MPa and no less than 7 178mm thick 7 178mm min drill 3 4 19mm Ø 9 229mm min from any edge Torque 90ft lbs 120Nm 4 min 102mm Embedment Depth WELD ON MOUNTING Welding procedure must be approved by an Engineer or other qualified person to be compatible with any and all structural operational charac teristics of the selected installation location Grade 5 or 8 bolt 5 8 11 x 1 3 ...

Страница 17: ...ied person Back Plate to be used with 5 8 16mm bolts or all thread Drill hole perpendicu lar into surface so bolt can pass freely through the substrate Nut must be fully threaded on the bolt to insure maximum strength ratings and integrity of anchor Bolt or All thread and nut not included with Back Plate ...

Страница 18: ...IES KIT CONTENTS PART NUMBER RACSWY1SBA Steel Mounting Hardware Kit RACSWY100S Swivel with Steel Mounting kit RACSWY1CSA Concrete Hardware Kit RACSWY100C Swivel with Concrete Mounting Kit RACSWP100N KIT Weld on Mounting Kit RACSWX100N Backing Plate Only ...

Страница 19: ... strength capable of supporting a static load applied in the directions permitted by the system of at least 10 000 lbf 22kN in the absence of certification The anchorage connector may be pulled in any direction shown in the LOADING CONDITIONS DIAGRAM Pg 20 5 5 139 7mm 2 25 ø 57 15mm 3 0 76 2mm 6 1 4 15 88cm 1 0 25 4mm Compression Bushing Retaining Bushing Cable Bolt Spoon Cone Sleeve 8 0 ø 203 2mm...

Страница 20: ...s on the inner wall See diagram below 2 Blow hole clean with compressed air 3 Refer to the diagram below for hole location and requirements 4 Always inspect the hole carefully when reusing a previously drilled hole 5 min depth 12 7cm 1 min 2 54cm Section View 10 25 4cm Drill 1 Ø 2 54cm min from any edge 6 min 15 24cm Hole to Edge Tensile Strength UTS 10 000 lbf 44kN Working Load WLL 1 000 lbs 454k...

Страница 21: ... make sure the cone is below the spoons Insert the anchor into hole so the base plate rest flat on the concrete surface 2 Pull up on the bolt while holding swivel flush with the concrete Tighten the bolt by turning it clockwise by hand until bolt is fastened flush to swivel Drop In Step 1 Step 2 Pull Up Bolt Twist Clockwise INSPECT BEFORE USE Check for kinked or frayed cables Look for signs of wea...

Страница 22: ...h 22 Step 1 Unscrew min of 3 4 1 9cm REMOVAL 1 Loosen bolt so that at least 3 4 1 9cm of threads are exposed TAP Step 2 2 Use a hammer to tap down bolt and disengage cone from the spoons Step 3 3 Pull the anchor from the hole ...

Страница 23: ...ection must be disposed of in a manner to prevent inadvertent further use Contact Honeywell Technical Service at 800 873 5242 if you have any questions 4 0 Inspection and Maintenance Inspection Miller Anchorage Connectors are designed for today s rugged work environments To maintain their service life and high performance all components should be inspected frequently Anchorage connectors must be v...

Страница 24: ...ty 1 person 310 lbs Working Load 2 000 lbs Model RACSWY100N WARNING All persons using this equipment must read understand and follow all instructions Failure to do so may result in serious injury or death INSPECT BEFORE USE COMPLIANCE OSHA 1910 66 1926 502 ANSI Z359 1 07 Z359 7 11 CE 0321 EN 795 1996 US PAT 8 424 638 5K Swivel AnchorRAC SWY050N 5K Stainless Steel Swivel Anchor RACSWY100N ...

Страница 25: ...User Instructions English 25 Aircraft Cable Length Specified by Customer Polyurethane Sleeve 4 0 3 16 Plate 5K Drop Through Swivel Anchor RACDTA 5K ...

Страница 26: ...0k Swivel Anchor Zinc Plated Steel Max Capacity 1 person 310 lbs Working Load 2 000 lbs Model RACSWY100N 10k Hybrid Anchor Zinc Plated Steel Max Capacity 1 person 310 lbs Model RACSWH100Y WARNING All persons using this equipment must read understand and follow all instructions Failure to do so may result in serious injury or death INSPECT BEFORE USE COMPLIANCE OSHA 1910 66 1926 502 ANSI Z359 1 07 ...

Страница 27: ...pprouvé par Aprobado por Approved by Approuvé par Aprobado por Approved by Approuvé par Aprobado por Approved by Approuvé par Aprobado por Approved by Approuvé par Aprobado por Approved by Approuvé par Aprobado por DATE OF MANUFACTURE _________________________________________________ DATE DE FABRICATION FECHA DE FABRICACIÓN MODEL NUMBER ________________________________________________________ NUMÉ...

Страница 28: ...ontre les chutes Miller sont soumis à des essais pour vérifier qu ils résistent à une usure normale ils ne sont cependant pas indestructibles et peuvent s endommager en cas de mauvaise utilisation Notre garantie limitée à vie ne s applique pas à l usure normale ou à un usage abusif du produit Dans le cas peu probable où vous découvririez des défauts soit de fabrication soit de matériau dans le cad...

Страница 29: ...User Instructions English 29 ...

Страница 30: ...reet Franklin PA 16323 USA Toll Free 800 873 5242 Fax 800 892 4078 Download this manual at www millerfallprotection com Téléchargez ce manuel à l adresse www millerfallprotection com Puede bajar por Internet este manual en www millerfallprotection com ...