![Honeywell MagneW 3000 Plus Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/honeywell/magnew-3000-plus/magnew-3000-plus_application-manual_151860051.webp)
36-KI-16-25
Page 4 of 5
Availability
MGG14IF
TABLE V (continued)
Selection
D - Electrodes
SUS316L
_ _ _ _ _ _ _ L _ _ _ _ _
*
Hastelloy C
(with Teflon PFA only)
_ _ _ _ _ _ _ C _ _ _ _ _
c
Titanium
_ _ _ _ _ _ _ K _ _ _ _ _
Zirconium
(with Teflon PFA only)
_ _ _ _ _ _ _ H _ _ _ _ _
c
Tantalum
(with Teflon PFA only)
_ _ _ _ _ _ _ T _ _ _ _ _
c
Tungsten Carbide
_ _ _ _ _ _ _ W _ _ _ _ _
Platinum-Iridium
(with Teflon PFA only)
_ _ _ _ _ _ _ P _ _ _ _ _
c
Alloy 20
(with Teflon PFA only)
_ _ _ _ _ _ _ A _ _ _ _ _
c
Hastelloy B
(with Teflon PFA only)
_ _ _ _ _ _ _ B _ _ _ _ _
c
SUS304
(with Teflon PFA only)
_ _ _ _ _ _ _ E _ _ _ _ _
c
Monel
(with Teflon PFA only)
_ _ _ _ _ _ _ M _ _ _ _ _
c
Nickel
(with Teflon PFA only)
_ _ _ _ _ _ _ N _ _ _ _ _
c
SUS316L Protruded Tip
(with Teflon PFA only)
_ _ _ _ _ _ _ 1 _ _ _ _ _
c
SUS316L for Alumina with Flat Tip
(with Teflon PFA only)
_ _ _ _ _ _ _ 2 _ _ _ _ _
c
SUS316L for Alumina with Pointed TIp
(with Teflon PFA only)
_ _ _ _ _ _ _ 3 _ _ _ _ _
c
E - Grounding Rings
SUS316
_ _ _ _ _ _ _ _ S _ _ _ _
*
SS Top Hat Style (Upstream Only)
_ _ _ _ _ _ _ _ G _ _ _ _
Hastelloy C
(with Teflon PFA only)
_ _ _ _ _ _ _ _ C _ _ _ _
c
Titanium
_ _ _ _ _ _ _ _ K _ _ _ _
Zirconium
(with Teflon PFA only)
_ _ _ _ _ _ _ _ H _ _ _ _
c
Tantalum
(with Teflon PFA only)
_ _ _ _ _ _ _ _ T _ _ _ _
c
Platinum
(with Teflon PFA only)
_ _ _ _ _ _ _ _ P _ _ _ _
c
Alloy 20
(with Teflon PFA only)
_ _ _ _ _ _ _ _ A _ _ _ _
c
Hastelloy B
(with Teflon PFA only)
_ _ _ _ _ _ _ _ B _ _ _ _
c
SUS304
(with Teflon PFA only)
_ _ _ _ _ _ _ _ E _ _ _ _
c
SUS316L
(with Teflon PFA only)
_ _ _ _ _ _ _ _ L _ _ _ _
c
Nickel
(with Teflon PFA only)
_ _ _ _ _ _ _ _ N _ _ _ _
c
SS Top Hat Style (Upstream Only)
_ _ _ _ _ _ _ _ G _ _ _ _
c
F - Wiring Connection/Watertight Gland
Integral Type
_ _ _ _ _ _ _ _ _ 1 _ _ _
*
G - Face to Face Dimension
Standard
_ _ _ _ _ _ _ _ _ _ A _ _
*
Competitive
(refer to Table 103 and consult factory)
_ _ _ _ _ _ _ _ _ _ 9 _ _
c
H - Installation/Wiring Direction
Integral Type
_ _ _ _ _ _ _ _ _ _ _ H _
*
I - Calibration
Standard Calibration - 2 Point (0, 100%) w/ Master Converter
_ _ _ _ _ _ _ _ _ _ _ _ R
*
3 Point (0, 50, 100%) with Master Converter
_ _ _ _ _ _ _ _ _ _ _ _ P
5 Point (0, 25, 50, 75, 100%) with Master Converter
_ _ _ _ _ _ _ _ _ _ _ _ Q
2 Point (0, 100%) with Customer’s Specific Converter
_ _ _ _ _ _ _ _ _ _ _ _ J
3 Point (0, 50, 100%) with Customer’s Specific Converter
_ _ _ _ _ _ _ _ _ _ _ _ A
5 Point (0, 25, 50, 75, 100%) with Customer’s Specific Converter
_ _ _ _ _ _ _ _ _ _ _ _ E