background image

T4 

PROGRAMMABLE THERMOSTAT 

TROUBLESHOOTING – T4 and T4M only

Problem Display

Possible Cause

Remedy

Thermostat display is blank

Batteries exhausted, installed 
incorrectly or tab hasn't been 
removed

Unclip thermostat from wall and check 
battery installation - replace batteries if 
necessary

Display shows 
(only for T4)

Battery power critically low

Unclip thermostat from wall and replace 
batteries immediately

Display shows

Faulty temperature sensor

Replace thermostat or check wiring to 
remote temperature sensor if fitted

Thermostat shoes heat 
demand      but boiler doesn’t 
respond

a. Boiler water already at 
temperature
b. Faulty wiring connection

a. Normal behaviour – wait for water 
temperature to drop
b. Check wiring at thermostat and boiler 
terminals

TROUBLESHOOTING – T4R

Problem Display

Possible Cause

Remedy

Thermostat display is blank

Batteries exhausted, installed 
incorrectly or tab hasn't been 
removed

Pull thermostat from wall bracket or 
table stand and check battery installation 
- replace batteries if necessary

Display shows 

Battery power critically low

Pull thermostat from wall bracket or 
table stand and check battery installation 
- replace batteries if necessary

Display shows

Faulty temperature sensor

Replace thermostat or check wiring to 
remote temperature sensor if fitted

Thermostat shoes heat 
demand      but boiler doesn’t 
respond

a. Boiler water already at 
temperature
b. Faulty wiring connection

a. Normal behaviour – wait for water 
temperature to drop
b. Check wiring at thermostat and boiler 
terminals

Thermostat displays shows

and Receiver Box        

LED is flashing RED

Wireless communication with 
Receiver Box is lost

Move thermostat to a location where 
wireless communication is reliable

Thermostat displays shows

and Receiver Box        

LED is flashing OFF

Thermostat and Receiver Box 
not bound

Move thermostat to a location where 
wireless communication is reliable

Receiver Box        LED is flashing 
ORANGE 

Receiver Box is in bind mode

Wait for bind mode to time out (3min) or 
bind a Thermostat

ORDERING SPECIFICATION

Description

Model

EAN code

Literature

T4 wired thermostat 

T4H110A1021

5025121381215

All packaging contains 6 

languages: English, 

Dutch, French, German, 

Italian and Spanish

T4  wired thermostat for 

OpenTherm boilers

T4H310A3032

5025121381208

T4 wireless thermostat

Y4H910RF4003

5025121381079

Содержание LYRIC T4

Страница 1: ...able stand or wall mounted thermostat options to fit new and replacement installations Backlight for easier viewing in all light conditions Factory programmed daily weekly or 5 2 default heating schedule Schedule options with 4 or 6 independent set points to suit comfort needs Set point temperature always displayed OFF position has an integral frost protection setting at minimum 5 C so that pipes ...

Страница 2: ...T4 PROGRAMMABLE THERMOSTAT Reference to the icons Manual override Reset Delete binding Status LED Communication with thermostat Binding mode RECEIVER BOX INTERFACE THERMOSTAT DISPLAY BUTTON LAYOUT ...

Страница 3: ...to 3A inductive 0 6 pf Selectable by application see installer set up Terminal block capable of accepting wires up to 1 5 mm2 From back via large wall box opening From bottom with cable clamps Mains wiring left Low voltage wiring right 110 x 110 x 40 mm 30 Receiver box Operating temperature range Shipping and storage temperature Humidity range EMC LVD R TTE Wire access ErP 0 to 40 C 20 to 55 C 10 ...

Страница 4: ...nt to locate the thermostat It will read the remote sensor every 1 minute The sensor can be connected up to 50 meters from the unit Useful for commercial premises where the public may tamper with the product Optimisation optimum start optimum stop and delayed start Optimum Start learns how long it takes your system to reach the temperature you want It turns on the heating system earlier to make su...

Страница 5: ...weekday weekend schedule 3 1 day same schedule every day of the week 7NP Number of periods 4 4 or 6 number of heating periods per day 9LC Fail safe mode 0 0 Deactivated 1 Activated 10BL Backlight 1 0 Deactivated 1 Activated only on demand 11CL Clock format 0 0 24h 1 12h AM PM 12DS Daylight saving time change 1 0 Deactivate Daylight saving time change 1 Automatically change time during DST 13TO Tem...

Страница 6: ... Leave at least 30cm distance from any metal objects including wall boxes and boiler housing Loosen the front screw to remove cover or tighten it when the cover is back in position Install Receiver Box T4R only A Wall box or Rear wiring Hinge open the terminal block flap to access the cables and wall box screw holes B Surface wiring Hinge open the terminal block flap to access the cables and wall ...

Страница 7: ...G T4R only The T4R thermostat wireless kit comes pre bound from the factory The binding operation described below is only required if The T4 thermostat or the Receiver box is replaced The T4 thermostat or the Receiver box has incorrect or no binding data stored To bind rebind Note When the Receiver box has been bound before first press with a small pin the pinhole for approximately 3 seconds to re...

Страница 8: ...T4 PROGRAMMABLE THERMOSTAT WIRING T4 and T4M only WIRING T4R only ...

Страница 9: ...lly low Pull thermostat from wall bracket or table stand and check battery installation replace batteries if necessary Display shows Faulty temperature sensor Replace thermostat or check wiring to remote temperature sensor if fitted Thermostat shoes heat demand but boiler doesn t respond a Boiler water already at temperature b Faulty wiring connection a Normal behaviour wait for water temperature ...

Страница 10: ......

Отзывы: