Honeywell LXL-1000 Скачать руководство пользователя страница 41

 

 

– 41 – 

Trouble Conditions

 (cont’d)

 

 
 

Other Trouble 

Displays

(Continued

AC LOSS

 

The system is operating on battery power 

(or 

NO AC

only due to an AC power failure.  

 

 

If only some lights are out on the 
premises, check circuit breakers and 
fuses and reset or replace as necessary.  

 

 

If AC power cannot be restored and a 
“low system battery” message appears 
(see previous page), 

CALL FOR 

SERVICE

 

Busy-Standby 

(or 

dI

If this message remains displayed for 
more than 1 minute, system is disabled. 

CALL FOR SERVICE

 

Long Rng Trbl 

If part of your system, back-up Long  

(or 

bF

Range Radio communication has failed.  

  

CALL 

FOR 

SERVICE.

 

 

 

TELCO FAULT 

  

The telephone line has a problem. 

(or 

CHECK 94

) CALL 

FOR 

SERVICE. 

 

 

Total Power Failure

If there is no keypad display at all, and the READY indicator is not 
lit, operating power (from AC and back-up battery) for the system 
has been interrupted and the system is inoperative. 

CALL FOR 

SERVICE.  

 

In The Event Of Telephone Operational Problems 

In the event of telephone operational problems, disconnect the control from the phone line by 
removing the plug from the phone wall jack. We recommend that your installer demonstrate this 
disconnection on installation of the system. Do not attempt to disconnect the phone connection 
inside the control. Doing so will result in the loss of your phone lines. If the regular phones work 
correctly after the control

 

has been disconnected from the phone wall jack, the control has a 

problem and you should immediately call for service. If upon disconnection of the control, there is 
still a problem on the phone line, notify the Telephone Company that they have a problem and 
request prompt phone repair service. The user may not under any circumstances attempt any 
service or repairs to the security system. Repairs must be made only by authorized service (see 
the LIMITED WARRANTY statement for information on how to obtain service).   

 

www.PDF-Zoo.com

Содержание LXL-1000

Страница 1: ... XL SERIES ADEMCO LYNX XL SERIES ADEMCO LYNX XL SERIES Security Systems Security Systems Security Systems Security Systems LXL LXL LXL LXL 1000 LXL 1000 LXL 1000 LXL 1000 LXL 1010 1010 1010 1010 User Guide User Guide User Guide User Guide www PDF Zoo com ...

Страница 2: ...premises This would include any skylights that may be present and the upper windows in a multi level building In addition we recommend that radio backup be used in a security system so that alarm signals can still be sent to the Central Monitoring Station in the event that the telephone lines are out of order alarm signals are normally sent over the phone lines EARLY WARNING FIRE DETECTION Early w...

Страница 3: ...y Entry Delay On 18 NIGHT STAY Mode Arms Perimeter Only Plus Selected Zones 18 INSTANT Mode Arms Perimeter Only Entry Delay Off 18 AWAY Mode Arms Entire System Entry Delay On 18 MAXIMUM Mode Arms Entire System Entry Delay Off 18 Arming Commands 19 Single Button Arming 20 Single Button Step Arming 20 Disarming and Silencing Alarms 21 Bypassing Protection Zones 22 Using the BYPASS Key 22 Quick Bypas...

Страница 4: ...nd Attributes 33 Scheduling 34 About Scheduling 34 Creating Schedules 34 Event Logging Procedures 36 About Event Logging 36 Viewing the Event Log 36 Table of Event Log Codes 37 Testing the System 38 About Testing the System 38 Trouble Conditions 39 Maintaining Your System 42 Fire Alarm System 43 Quick Guide to Basic System Functions 47 Summary of Audible Visual Notifications 48 Regulatory Statemen...

Страница 5: ...t include fire protection check with your installer System Basics Burglary Protection Several modes of burglary protection Stay Night Stay Away Instant Maximum STAY arms perimeter zones only and entry delay is on INSTANT same as STAY except entry delay is off NIGHT STAY arms perimeter zones and selected interior zones entry delay on AWAY arms perimeter and all interior zones entry delay is on MAXI...

Страница 6: ...system You can also use the step arming feature if programmed to arm the system This is a function key that allows you to arm the system in one of three modes by simply pressing the key repeatedly To disarm the system enter your user code then press the OFF key Alarms When an alarm occurs both the keypad and external sounders will sound and the keypad will display the zone s causing the alarm If y...

Страница 7: ...me each day LED Indications The control utilizes three Security System Control Status LEDs that indicate control arming state and power status as follows READY LED Green Lit when the system is disarmed and ready to be armed no open zones If the system is disarmed and the green light is off the system is not ready one or more zones are open POWER LED Yellow Indicates system power status Lit Steady ...

Страница 8: ...ARMED READY RECORD VOLUME PLAY STATUS FUNCTION VOICE SPEAKER CONTROL LEDS FUNCTION KEYS LCD DISPLAY MICROPHONE MESSAGE LED Message Center Functions To Press these keys Notes record a message FUNCTION 0 VOICE 1 OFF RECORD The red MESSAGE LED lights Message remains in memory until a new message is recorded end recording 1 OFF RECORD The red MESSAGE LED flashes indicating message waiting play a messa...

Страница 9: ...ing the premises it indicates that an alarm has occurred during your absence and an intruder may still be on the premises LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location Your keypads are functionally the same but may have different types of displays depending on the type installed with your system Alpha Display 2 line alpha display keypads feature a 2 line 32 character alphanu...

Страница 10: ... ARMED READY RECORD VOLUME PLAY STATUS FUNCTION VOICE 1 OFF 4 MAX 7 INSTANT READY 2 AWAY 5 TEST 8 CODE 0 3 STAY 6BYPASS 9CHIME ARMED READY 5828 00 001 V0 5828V FIXED WORD KEYPAD 5828 FIXED WORD KEYPAD 5839 004 V0 PANIC READY INSTANT CODE CHIME MAX TEST BYPASS OFF AWAY STAY 4 5 6 7 8 0 1 2 3 9 DISARMED READY TO ARM FIRST PRESS ANY KEY TO PLACE KEYPAD INTO ACTIVE STATE THEN PRESS KEY TO OBTAIN STATU...

Страница 11: ...em is operating on backup battery power AC Appears when AC power is present CHIME Appears when the chime feature is activated BAT Low battery condition in a wireless sensor if zone number displayed or low system battery if no zone number displayed ALARM Appears when an intrusion has been detected and the system is armed also appears during a fire alarm or audible emergency alarm Accompanied by the...

Страница 12: ...ber on the following pages for a description of usage When entering codes and commands sequential key depressions must be made within 4 5 seconds of one another If 4 5 seconds elapse without a key depression the entry will be aborted and must be repeated from its beginning Be sure to observe this precaution when performing any of the procedures in this manual If you make a mistake while entering a...

Страница 13: ...tem status 4 3 STAY Arms perimeter portion of burglary system only Interior protection is not armed allowing movement within premises without causing an alarm PLAY On Voice keypads used in conjunction with the FUNCTION and VOICE keys to play the recorded message On Voice keypads used in conjunction with the FUNCTION and VOLUME keys to raise the message and voice system status volume 5 MIC On voice...

Страница 14: ...ey a second time annunciates and displays system and or zone faults if they exist 16 KEYS 0 9 Used to enter your security code s and to perform their associated system functions after the security code has been entered 17 FUNCTION KEYS If your keypad has A B C D keys they may have been programmed for a variety of functions including panic emergency functions For details see the Function Keys secti...

Страница 15: ...ff an alarm Exit delay begins immediately after arming your system in any arming mode and Alpha Display keypads display the message You May Exit Now When You may exit now disappears the system is fully armed If programmed a slow beeping will sound during the exit delay period until the last 10 seconds which then changes to fast beeping alerting you to the end of exit delay If you cannot leave with...

Страница 16: ...F If you do not disarm the system before the entry delay ends and an entry exit door or interior zone is still open the alarm sound continues and an exit alarm message is sent to the Central Monitoring Station The message EXIT ALARM or EA is displayed on the keypad along with a zone number indicating the faulted zone To stop the alarm you must disarm the system by entering your 4 digit code follow...

Страница 17: ...yed The keypad s READY indicator lights when all protection zones have been either closed or bypassed 3 Arm the system as desired Alpha Display DISARMED PRESS TO SHOW FAULTS Fixed Word Display Zone no and NOT READY Voice Status Voice keypads if installed can announce system status and faulted zones up to 3 zone descriptors if the Voice Status feature is turned on To turn the Voice Status feature o...

Страница 18: ...zones are armed and cause an alarm if anyone enters those areas e g waking in the middle of the night To avoid sounding an alarm you must disarm the system before any activity takes place in those interior zones INSTANT Mode Arms Perimeter Only Entry Delay Off Used when staying inside and do not expect anyone to use an entry exit door Arms same as STAY mode An alarm sounds immediately if any prote...

Страница 19: ...d ARMED indicator lights Leave the premises through an entry exit door during the exit delay period to avoid causing an alarm The keypad beeps rapidly during the last 5 seconds of the exit delay to warn you that it is ending MAXIMUM security code 4 MAX same as AWAY described above Note that entry delay is turned off Quick Arming If Quick Arming was programmed by the installer the key can be presse...

Страница 20: ...ned function key for 2 seconds no code is required Function keys are shown below 3 2 1 6 5 4 9 8 7 0 READY INSTANT OFF CODE AWAY TEST CHECK STAY BYPASS A B C D ADT3000 007 V0 Alpha Display DISARMED READY TO ARM Fixed Word Display Green LED lit 2 The keypad begins beeping and displays the armed message The red ARMED indicator also lights Alpha Display ARMED AWAY YOU MAY EXIT NOW Fixed Word Display ...

Страница 21: ...tone to confirm that the system is disarmed and the RED LED indicator will go out If the system was in ALARM note the zone in alarm on the keypad display and correct the problem close door window etc After correcting the problem clear the keypad s Memory of Alarm display as described below Alpha Display DISARMED READY TO ARM Fixed Word Display READY Clear a Memory of Alarm Enter your 4 digit secur...

Страница 22: ...will not allow fire zones to be bypassed Zones are automatically unbypassed when the system is disarmed 1 6 BYPASS zone numbers see below Security Code Enter the 2 digit zone number s for the zone s to be bypassed e g 06 10 13 etc Single digit zone numbers must be preceded by a zero e g 05 06 Alpha Display DISARMED PRESS TO SHOW FAULTS Fixed Word Display NOT READY 2 When finished the keypad will m...

Страница 23: ...ts all open zones will be displayed and automatically bypassed Make sure that only those zones that you wish to leave unprotected are bypassed and that there are no other zones unintentionally left open Alpha Display DISARMED PRESS TO SHOW FAULTS Fixed Word Display NOT READY 2 Wait for all bypassed zones to be displayed then arm the system as desired Ask your installer if Quick Bypass is active fo...

Страница 24: ...m Fixed Word Display CHIME To turn Chime Mode off 9 CHIME Security Code The CHIME message will disappear Alpha Display DISARMED READY TO ARM Fixed Word Display READY Using the Voice Chime Voice keypads have a feature that works in concert with the Chime Mode called Voice Chime Voice chime provides a voice status annunciation chime and display when any faulted entry exit or perimeter zone exists As...

Страница 25: ... the box beneath that key Setting the Date and Time You can set the time and date by doing the following 1 6 3 Security Code Alpha Display DISARMED READY TO ARM 2 Press when the time date is displayed A cursor appears under the first digit of the hour To move cursor ahead press To go back press Enter the 2 digit hour setting Enter the 2 digit minute setting Press 1 for PM or 0 for AM Enter the las...

Страница 26: ...tivate a Panic Function Press and hold down for at least 2 seconds whichever lettered key on the keypad has been programmed for the desired emergency function OR Press both keys of the assigned key pair at the same time Normal Alpha Display DISARMED READY TO ARM Fixed Word Display READY Typical Panic Alpha Display ALARM 96 ZONE 96 Fixed Word Display 96 and ALARM 1 OFF 4 MAX 7 INSTANT READY 2 AWAY ...

Страница 27: ...e macros can be assigned See the chart at the back of this manual for the key s assigned for macros 1 6 6 Security Code Alpha Display DISARMED READY TO ARM 2 Enter the macro number 1 2 to be programmed at the Select Macro prompt Remember only one macro can be assigned to each key SELECT MACRO 1 2 0 3 If a macro has been previously defined the keystrokes are shown on the bottom line of the display ...

Страница 28: ...ty system in the AWAY mode The procedures in the table that follows show you how you would program this macro Function Keystrokes Required Keypad Display 1 Bypass zones 02 03 Press BYPASS 6 key then 2 digit zone numbers 02 03 6 0 2 0 3 2 Insert terminator Press the D key for at least 2 seconds 6 0 2 0 3 F 3 Turn light on device 01 Press and 7 key for device ON and 01 key for selecting device 1 6 0...

Страница 29: ...ally turned on or off using the commands described below See your installer for a list of devices that may be set up for your system A list of these devices is provided at the back of this manual for you to fill out To Activate Devices 7 2 digit device number Security Code Devices associated with that device number activate To Deactivate Devices 8 2 digit device number Security Code Devices associ...

Страница 30: ...vent Code È È È È Optional 16 digits Æ Æ Æ Æ AAAAAAAAAAAAAAAA BBB CCCC Å Å Å Å 4 digit User or Zone No A B C Optional 16 digits for Account numbers PIN numbers or any other data programmed by the installer if required A 3 digit code that describes the event that has occurred in your system see for event codes table below A 4 digit User or Zone number depending on the type of event that has occurre...

Страница 31: ... for beep then press the pager number 1 2 representing the pager intended to receive the message 2 The recipient on seeing the 999 9999 message will understand the prearranged meaning of this signal If no number is pressed the message is sent to pager 1 Alpha Display DISARMED READY TO ARM Fixed Word Display READY 999 9999 Pager Display Latch Key Paging You can program a schedule that causes a page...

Страница 32: ...you usually need to do when adding users is assign a user number and a security code Authority Level Definitions Authority levels define the system functions a particular user can cannot perform Level Title Explanation N A System Master Reserved for user 02 Can perform all system functions and assign default 1234 codes can change its own code as follows Master code 8 02 new master code new master ...

Страница 33: ...s see definitions on previous page users 04 49 0 0 standard user 2 guest 1 arm only 3 duress Access Group System Master Code 8 user no 2 group 1 8 Factory Defaults none You can assign users to a group then set an access schedule that defines the times this group of users can operate the system The system ignores these users outside the scheduled times RF User Number System Master Code 8 user no 4 ...

Страница 34: ...duled event 01 turn a programmed output on or off ENTER EVENT see Using Device Commands section for a list of output device numbers used in your system 02 set a user access schedule for one or more users see Security Codes section for an explanation of access groups 03 send a latch key report to a pager if the system is not disarmed by a specified time message sent is 777 7777 04 automatically arm...

Страница 35: ...Enter the desired repeat option 0 no repeat 1 repeat schedule weekly 2 repeat schedule biweekly every other week 3 repeat schedule every third week 4 repeat schedule every fourth week e g To make a schedule that happens everyday you would select all days with a repeat count of 1 To make a schedule that runs for one week then stops select everyday with a repeat count of 0 REPEAT OPTION 0 4 X 10 Sel...

Страница 36: ...ing of any new event Viewing the Event Log 1 6 0 Master Code Alpha Displays DISARMED READY TO ARM 2 The system displays the most recent event as follows event number type of event identified by its corresponding code refer to the code table that follows zone or user number depending on type of event time and date of the event s occurrence 3 Pressing displays previous events back in time Pressing d...

Страница 37: ...sion Mod Supervision 341 Trouble ECP Cover Tamper 344 RF Receiver Jam 351 Telco Line Fault 353 Long Range Radio Trouble 373 Fire Loop Trouble 374 Exit Error Alarm Code Definition 380 Global Trouble Trouble Day Night 381 RF Supervision Trouble 382 Supervision Auxiliary Wire Zone 383 RF Sensor Tamper 384 RF Sensor Low battery 401 Disarmed Armed AWAY Armed STAY 403 Schedule Arm Disarm AWAY 406 Cancel...

Страница 38: ...en for three beeps from the keypad Identification zone number or zone description of each faulted protection point should appear on the display The display clears when the door or window is closed 5 Walk in front of any interior motion detectors if used and listen for three beeps The identification of the detector should appear on the display when it is activated The display clears when no motion ...

Страница 39: ... enter the OFF sequence security code plus OFF key twice If the display persists CALL FOR SERVICE Note A display of CHECK 90 indicates that RF interference may be impeding the operation of wireless sensors in the system See Rcvr Jam on next page 2 If there are wireless sensors in your system the CHECK condition may also be caused by some change in the environment that prevents the wireless receive...

Страница 40: ...pad If this condition persists for more than one day with AC present CALL FOR SERVICE LO BAT Indicates that there is a low battery zone descriptor condition in the wireless transmitter or BAT with number displayed 00 is RF keypad zone No Accompanied by a single beep about once every 40 seconds at the keypad Either replace the battery yourself or CALL FOR SERVICE If the battery is not replaced with...

Страница 41: ...rupted and the system is inoperative CALL FOR SERVICE In The Event Of Telephone Operational Problems In the event of telephone operational problems disconnect the control from the phone line by removing the plug from the phone wall jack We recommend that your installer demonstrate this disconnection on installation of the system Do not attempt to disconnect the phone connection inside the control ...

Страница 42: ...er and the portable wireless keypad and displays a low battery message A low battery in a portable wireless keypad is detected as soon as one of its keys is pressed and displayed as 00 Battery operated smoke detectors with a low battery also emit a single chirp sound approximately once every 20 30 seconds Alkaline batteries provide a minimum of 1 year of operation and in most units and application...

Страница 43: ...YPAD FIXED WORD DISPLAY KEYPAD Silencing Fire Alarms and Clearing Memory of Alarm 1 You can silence the alarm at any time by pressing the OFF key To clear the display enter your code and press the OFF key again to clear Memory of Alarm 2 If the Keypad s FIRE display does not clear after the second OFF sequence smoke detectors may still be responding to smoke or heat producing objects in their vici...

Страница 44: ...ify your local Fire Department immediately 4 If no flames or smoke are apparent investigate the cause of the alarm The zone number s of the zone s in an alarm condition will be displayed at the keypad Using the Panic Key s Assigned for FIRE Emergency A key or key pair may have been assigned for manually initiating a FIRE alarm See the Panic Keys section for key assignments For convenience indicate...

Страница 45: ...tion is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows A smoke detector installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit including basements and excluding crawl spaces and unfinished attics In addition the NFPA recommends that you instal...

Страница 46: ...d 3 Sketch a floor plan of the building Show windows doors stairs and rooftops that can be used to escape Indicate escape routes for each room Keep these routes free from obstruction and post copies of the escape routes in every room 4 Assure that all bedroom doors are shut while you are asleep This will prevent deadly smoke from entering while you escape 5 Try the door If the door is hot check yo...

Страница 47: ...red Determine cause Disarm System Enter code Press OFF key Also silences sounders Memory of alarm remains until cleared Clear Alarm Memory After disarming enter code again Press OFF key again Keypad beeps rapidly on entry if alarm has occurred while absent Alarm display will remain upon disarming until cleared Duress if active and connected to Central Station Arm or disarm normally but use your 4 ...

Страница 48: ...TTER a Opened zone numbers will appear b BAT displayed with zone number of transmitter TWO SHORT BEEPS Keypad only ARM AWAY or MAXIMUM AWAY is displayed Red ARMED indicator is lit THREE SHORT BEEPS Keypad only a ARM STAY NIGHT STAY INSTANT b ZONE OPENED WITH SYSTEM IN CHIME MODE a STAY or INSTANT is displayed Red ARMED indicator is lit b CHIME displayed zone number of open protection zone will be ...

Страница 49: ...tions will appear b LO BAT displayed with description of transmitter TWO SHORT BEEPS Keypad only ARM AWAY or MAXIMUM ARMED AWAY or MAXIMUM displayed Red ARMED indicator lit THREE SHORT BEEPS Keypad only a ARM STAY NIGHT STAY OR INSTANT b ZONE OPENED WHILE SYSTEM IS DISARMED a ARMED STAY or ARMED INSTANT displayed Red ARMED indicator lit b CHIME displayed descriptor of open protection zone will be ...

Страница 50: ...B 003 du Canada TELEPHONE MODEM INTERFACE FCC Part 68 This equipment complies with Part 68 of the FCC rules On the front cover of this equipment is a label that contains the FCC registration number and Ringer Equivalence Number REN You must provide this information to the telephone company when requested This equipment uses the following USOC jack RJ31X This equipment may not be used on telephone ...

Страница 51: ...ss yes no Automatic Paging yes no users Function Keys A B C D Comments Single Button Arming Step Arming Paging see Paging chart Time Date Display Macro Key 1 Macro Key 2 Emergency Key Personal Emergency Key Silent Alarm Emergency Key Audible Alarm Emergency Key Fire Device Activation Device Emergency Keys A 1 B C 3 www PDF Zoo com ...

Страница 52: ...evel 1 level Access Group 2 group RF Zone Number 4 zone no Pager on off 5 0 1 01 installer installer 1 02 system master master 1 03 4 1 04 0 1 05 0 1 06 0 1 07 0 1 08 0 1 09 0 1 10 0 1 11 0 1 12 0 1 13 0 1 14 0 1 15 0 1 16 0 1 17 0 1 18 0 1 19 0 1 20 0 1 21 0 1 22 0 1 23 0 1 24 0 1 25 0 1 26 0 1 27 0 1 28 0 1 29 0 1 30 0 1 31 0 1 32 0 1 Authority Levels 0 standard user 1 arm only 2 guest 3 duress ...

Страница 53: ...01 events for 02 events Time Time 1 4 yes no see device list below enter 1 8 Day Day 01 02 03 04 Events 00 clear event 03 latch key report 06 auto disarm 01 device on off 04 forced STAY arm 07 display reminder 02 user access 05 forced AWAY arm Repeat Options 0 none 1 repeat weekly 2 repeat every other week 3 repeat every third week 4 repeat every fourth week List of Output Devices Device Descripti...

Страница 54: ...t injury or death Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation manual Passive Infrared Detectors do not provide volumetric area protection They do create multiple beams of protection and intrusion can only be detected in unobstructed areas covered by those beams They cannot detect motion or intrusion that takes place beh...

Страница 55: ...surance Company Policy No LXL 1000 1010 Other _______________________________ Type of Alarm Burglary Fire Both Installed by Serviced by Name Name Address Address B NOTIFIES Insert B Burglary F Fire Local Sounding Device Police Dept Fire Dept Monitoring Station Name Address Phone C POWERED BY AC With Rechargeable Power Supply D TESTING Quarterly Monthly Weekly Other continued on other side www PDF ...

Страница 56: ...ement Living Room Dining Room Hall F BURGLARY DETECTING DEVICE LOCATIONS Front Door Basement Door Rear Door All Exterior Doors 1 st Floor Windows All windows Interior locations All Accessible Openings Including Skylights Air Conditioners and Vents G ADDITIONAL PERTINENT INFORMATION Signature Date www PDF Zoo com ...

Страница 57: ...essage 19 Armed Away 20 Armed Stay 20 Attributes 33 Audible Emergency Alarm 11 Authority Levels 6 32 Automatic Paging 30 Away 3 5 7 11 15 18 19 20 27 28 34 37 47 48 49 53 B Babysitter Code 32 Backlighting 9 Back Up Battery 11 41 Battery Life 42 Battery Replacement 42 Battery Operated Smoke Detector 42 Burglary Protection 5 Busy Standby 41 Bypass 5 11 22 Bypass Zone s 47 Bypass Message 22 23 Bypass...

Страница 58: ...Delay Period 19 Exit Delay Restart 15 Exit Error Alarm 37 External Sounder 38 External Sounders 6 F False Alarms 16 18 FC 40 Fire 5 11 Fire Alarm 11 26 43 Fire Detection Equipment 45 Fire Display 11 43 Fire Emergency 44 Fire Message 43 Fire Protection 5 Fire Zone 11 Fixed Word Display 9 Fixed Word Display 11 Fixed Word Display Keypads 13 48 Flip Down Front Door 12 Function Key Arming 19 Function K...

Страница 59: ... No AC 11 41 Not Ready 11 17 O Open Circuit 41 Open Zone 17 Owner s Premium Credit Request 55 P Pager Display Format 30 Pager Displays 30 Pagers 30 Paging Feature 4 7 30 31 Panic Alarms 47 Panic Keys 26 44 Path of Escape 46 Personal Emergency 26 Pets 18 PIN Number 30 Plan of Escape 46 Play a Message 8 Portable Wireless Keypad 42 Pre Designated Words 9 13 Primary Entrance 15 Protection Zone ID 13 Q...

Страница 60: ...Stay Mode 20 Step Arming 20 Subscriber Account Number 30 System Lo Bat 40 T Telco Line 37 Telephone Operational Problems 41 Temporal Pulse Sounding 43 Terminator 27 Test Mode 47 Testing The System 38 Total Power Failure 41 Trouble Conditions 39 Trouble Displays 40 41 Typical Check Displays 39 U User Codes 33 V Voice Chime 9 24 Voice Chime 24 Voice Keypads 9 Voice Message Center 8 W Warning Tones 4...

Страница 61: ...ABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Some states do not allow limitation on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above...

Страница 62: ... 62 NOTES www PDF Zoo com ...

Страница 63: ... 63 NOTES www PDF Zoo com ...

Страница 64: ... K9350V1DŠ K9350V1 3 05 Rev A www PDF Zoo com ...

Отзывы: