Honeywell L641AI039 Скачать руководство пользователя страница 2

L641 SURFACE CONTACT THERMOSTAT

EN0R 8444 

2

DIMENSIONS

SPECIFICATIONS

INSTALLATION

Dimensions in millimetres (inches in brackets)

Supply

 

voltage

:

  230 V~, 50...60 Hz

Switch action

:

  S.P.D.T. Type 1CL

Switch rating

:

  4(2) A, 230 V~

Temperature
setting range

:

  see table

Differential

:

  Approximately 10 K non-adjustable

Surface
temperature
range

:

  0 to 95

o

C

Ambient
temperature
range

:

  0 to 70

o

C

Mounting

:

  L641A mounts directly onto cylinder

using fixing strap provided
L641B mounts directly onto pipes
using fixing springs provided

Dimensions

:

  44 x 79 x 54mm (1.73" x 3.11" x

2.13")
(w x h x d)

Wiring

:

  3 terminals with wiring clamps,

accepting wires up to 1.5 mm

2

Mounting

The L641A cylinder thermostat should be mounted 

1

/

4

 to

 

1

/

3

of the way from the bottom of the domestic hot water cylinder
after removing a section of the insulation and cleaning the
surface.

The L641B pipe thermostat should be positioned less than
0.6 m (2') from the boiler, or on a supply pipe to a fan-coil
unit, close to the 3-port control valve.

IMPORTANT

1.  The installer must be a trained service

engineer

2.  Disconnect the power supply before beginning

installation

ORDERING SPECIFICATION

Model

Application

Temperature

Setting Range

L641Al039

Cylinder

Thermostat

Min, 40 to 80 

C

L641Bl004

Low Limit Pipe

Thermostat

Min, 10 to 40

o

 C

L641B1012

High Limit Pipe

Thermostat

50 to 95

o

C

L641Bl020

High Limit Pipe

Thermostat

40 to 95

o

C

Wiring

Cover removal

Wiring to terminals

Содержание L641AI039

Страница 1: ...ector on the front cover Wiring terminals are easily accessible Tamperproof temperature setting L641B Screwdriver slot temperature setting with optional manual setting knob supplied L641A Approvals B E A B meets EN 60730 DESCRIPTION The L641 is a surface contact thermostat designed to sense the water temperature in storage cylinders and water pipes and to provide temperature control temperature li...

Страница 2: ...cepting wires up to 1 5 mm2 Mounting The L641A cylinder thermostat should be mounted 1 4 to 1 3 of the way from the bottom of the domestic hot water cylinder after removing a section of the insulation and cleaning the surface The L641B pipe thermostat should be positioned less than 0 6 m 2 from the boiler or on a supply pipe to a fan coil unit close to the 3 port control valve IMPORTANT 1 The inst...

Страница 3: ...m of the cylinder 2 The L641B should be mounted less than 0 6 m 2 from the boiler 3 The L641B should be mounted on the boiler return pipe and used in conjunction with the T4360A FrostStat 4 The L641B should be set to approx 25o C and mounted on the supply pipe close to the 3 port control valve such as to sense the water temperature even when the valve is closed APPLICATION High Limit For Underfloo...

Страница 4: ...t to 25o C Set to 25o C WIRING DIAGRAMS L641A1039 DHWS ControL L641B1012 L641B1020 High Limit Terminal 2 used on Honeywell Y Plan systems Heating Load Timer Fan coil Unit Heating Load and existing controls L641B1004 Automatic Summer Winter Changeover XE90 Contacts C and 1 break on temperature rise L641B1004 Low Limit Frost Protection Connected to override existing time and temperature controls Con...

Отзывы: