Using
Functions
Indicator status
Selecting an installation location
Wall mounting: the distance between the gas sensor and the gas equipment or
valve should not be more than 4 meters, the distance from the sensor installation
to the ceiling should be less than 0.3 meters, but do not install the sensor directly
above the gas equipment. Below is a schematic drawing that will help you choose
the right location for the device.
Ceiling installation
The distance between the gas sensor and the gas equipment or valve should not
be more than 4 meters, do not install the sensor directly above the gas equipment.
Below is a schematic drawing that will help you choose the right location for the
device.
1.
Power supply for preheating
Before switching on the power, make sure that the power source is operating
properly;
Connect the device to the power supply - the buzzer sounds three times, after
which the red, yellow, green indicator flashes in turn. After about five minutes,
one long beep will sound, indicating the exit from the preheating mode, the green
indicator will light up.
* When using for the first time, or if the device has not been used for a long time,
please connect the sensor to the power supply
for 72 hours for further optimal operation of the device.
2.
Normal working status
In the absence of malfunctions or an alarm, the green indicator is constantly on;
when the «Sound / Self-diagnosis» button is pressed, the sensor switches to the
self-test mode (once in a row the red, yellow, green indicator flashes, and the
alarm sounds once). After completion of self-diagnosis, the sensor restores normal