ACUIX
TM
Fixed Dome User Guide
Document 800-01605 Rev A
17
04/08
1.
Select the location of the housing. Each ACUIX™ Fixed requires either a 17 to 28
VAC or an 11 to 16 VDC power source measured at the housing. Each ACUIX™
Fixed has a power consumption of 3.5W for the color cameras or 4.5W for the WDR
cameras. Ensure a 24 VAC/12 VDC @ 0.2A power source is available. See
for maximum wiring distances to the
dome.
2.
Remove the ceiling panel at the dome location.
3.
Place the ceiling tile on the dropped ceiling plate. Trim the ceiling tile so you can
press the ceiling tile into the dropped ceiling plate.
4.
Cut a hole in the ceiling tile flush with the hole in the center of the plate.
5.
If necessary, secure a safety cable (supplied by the installer) to a building support
structure. Honeywell recommends using a 3/32” plastic coated aircraft cable.
6.
Insert the housing in the ceiling
a.
Adjust the turning screws on the wing tabs to ensure the space between the
wing tabs and housing flange is greater than the thickness of the ceiling.
b.
Position the wing tabs flat against the housing. Insert the housing through the
hole in the ceiling tile. Using a Phillips screwdriver, turn the two screws in the
housing clockwise to rotate the tabs out and tighten the tabs against the ceiling
tile. The recommended maximum torque is 1–1.25 N-m or 0.74–0.92 lbf-ft or
8.85–11.06 lbf-in.
c.
Insert the housing through the hole in the ceiling, ensuring the wing tabs are flat
against the housing. The recommended maximum torque is 1–1.25 N-m
7.
See
for information on connecting the field
wiring to the interface board in the housing.
8.
See
Installing the Camera Assembly
for information on installing the
camera assembly and
Installing the Lower Dome
on page
23
for information on
installing the lower dome.
In-Ceiling Housing Installation
WARNING!
Installation must be performed by qualified technical
personnel and must be in accordance with all national and
local mechanical and electrical codes.
Perform the following steps to install an ACUIX™in-ceiling housing:
1.
Select the location of the housing. Each ACUIX™ Fixed requires either a 17 to 28
VAC or an 11 to 16 VDC power source measured at the housing. Each ACUIX™
Fixed has a power consumption of 3.5W for the color cameras or 4.5W for the WDR
cameras. Ensure a 24 VAC/12 VDC @ 0.2A power source is available. See
for maximum wiring distances to the
dome.
2.
Cut a 7/15-16” (201.2 mm) diameter hole in the ceiling.
Содержание JOSI-DBC012-N11
Страница 1: ...Document 800 01605 Rev A 04 08 Installation Guide ACUIX Fixed Dome ...
Страница 2: ...Revisions Issue Date Revisions A 04 08 New document ...
Страница 4: ...Rev A Document 800 01605 04 08 Contents 4 ...
Страница 6: ...Rev A Document 800 01605 04 08 Figures 6 ...
Страница 8: ...Rev A Document 800 01605 04 08 Tables 8 ...
Страница 32: ...32 Adjusting the Camera ...
Страница 36: ...36 Cable Guidelines ...
Страница 39: ......