background image

 

 

3

  

Mount the Sensor

 

 

IS335-013-V0

A

B

B

B

A

B

 

A

B

*

#6 x 1"

(3.5 mm x 25 mm)

IS

312QIG-

005-V

0

 

                                          

*

Not included

 

• 

[A]

 = Wall mounting holes. 

• 

[B]

 = Corner mounting holes. 

 
 

 

 

 

 

4

  R

oute Wires 

 

IS335-006-V0

Shielded
Cable
22-20 AWG
(0.32-0.52mm  )

2

 

 

5

 

Reinstall Circuit Board

 

 

IS335-012-V0

Push

Down

 

 

6

 

Connect Wires / Set Pet Immunity (PI) Jumpers

 

7

  

Assemble Front Cover

 

#6 x 1"

(3.5mm x 25mm)

C

NC

V+

V-

T1

T2

1

2

3

Pet Immunity

*Factory default

LED

Always

Enabled

IS335-007-V0

Disabled

*Enabled

Alarm

 90 mA, 15 VDC

Power

 12 mA max, 9-15 VDC

 

NC

V

-

V

+

C

12V

Zone

#

Zone
COM

Panel

Sensor

For Residential use with

compatible panels,

minimally Listed to UL 1023,

that produce visual and/or

audible troubles/alarms

 

 

 

 

 

Содержание IS335

Страница 1: ...f sight to all areas to protect Do not directly face windows Avoid close proximity to moving machinery fluorescent lights and heating cooling sources For use in applications with pets up to 80 pounds 36 kilograms 2 Retrieve Cover Locking Screw Open Sensor and Remove Circuit Board IS335 014 V0 Remove tape from back housing and retrieve cover locking screw 1 Press firmly on housing latch 2 Pull up t...

Страница 2: ...it Board IS335 012 V0 Push Down 6 Connect Wires Set Pet Immunity PI Jumpers 7 Assemble Front Cover 6 x 1 3 5mm x 25mm C NC V V T1 T2 1 2 3 Pet Immunity Factory default LED Always Enabled IS335 007 V0 Disabled Enabled Alarm 90 mA 15 VDC Power 12 mA max 9 15 VDC NC V V C Ground 12V Zone Zone COM Panel Sensor For Residential use with compatible panels minimally Listed to UL 1023 that produce visual a...

Страница 3: ...y less than 45 seconds 2 Walk through the detection area and observe the LED Detection Patterns PLAN VIEW ALL ZONES A B C 7 5ft 2 3m 0ft 0m 7ft 2m 13ft 4m 20ft 6m 27ft 8m 33ft 10m 40ft 12m 13ft 4m 0ft 0m 7ft 2m 13ft 4m 20ft 6m 27ft 8m 33ft 10m 40ft 12m 7ft 2m 0ft 0m 7ft 2m 13ft 4m 20ft 6m 20ft 6m 27ft 8m 33ft 10m 27ft 8m 33ft 10m Top View Side View Zones A 18 Lower B 46 Intermediate C 36 Long IS33...

Страница 4: ...yWebTech For the latest U S warranty information please go to www honeywell com security hsc resources wa or contact your local authorized Honeywell representative for product warranty information 2013 Honeywell International Inc Honeywell is a registered trademark of Honeywell International Inc All other trademarks are the properties of their respective owners 2 Corporate Center Drive Suite 100 P...

Отзывы: