IS335 Passive Infrared Motion Sensor – Installation Instructions
1
Select the Mounting Location
IS335-010-V0
1
≤ 80 lbs / 36 kg
6' 9" - 8' 9"
(2.1 - 2.7 m)
7' 6"
(2.3 m)
Optimal
Mounting location guidelines:
• The optimal range is obtained at a mounting height of 7’ 6” (2.3 m).
• Allow a clear line-of-sight to all areas to protect.
• Do not directly face windows.
• Avoid close proximity to moving machinery, fluorescent lights, and heating/cooling sources.
• For use in applications with pets up to 80 pounds (36 kilograms).
2
Retrieve Cover Locking Screw,
Open Sensor and Remove Circuit Board
IS335-014-V0
Remove tape from back housing
and retrieve cover locking screw.
1. Press firmly on housing latch.
2. Pull up to separate the front
and rear housing.
Pull Up PCB
Push Tabs
IS335-003-V0