background image

4

ORDERING INFORMATION

ITEM

DESIGNATION

ITEM NO.

Flame sensor

Flicker detector IRD 1020.1 side-on right 

blue

230V

16531

Flicker detector IRD 1020.1 side-on right 

white

230V

1653104

optional

Flicker detector IRD 1020.1 end-on viewing 

blue

230V

16532

Flicker detector IRD 1020.1 D end-on viewing 

blue

230V

16552

Flicker detector IRD 1020.1 end-on viewing 

white

230V

1653204

Flicker detector IRD 1020.1 end-on viewing 

blue

115V

16572

Flicker detector IRD 1020.1 side-on left 

blue

230V

16533

Mounting flange

Flange M93

230V

59093

Sensor cable

Plug type, 3-wire, 0.6 m with tag wire ends

7236001

The above ordering information refers to the standard version.
Special versions are also included in our product range.

Specifications subject to change without notice.

FLICKER DETECTOR IRD 1020.1

VARIANTS

35

3

26

4.5

15.1

48

ø20.5

4

17

14

104

29

50

44

ø13.5

21.8

HOLDER M93

Satronic

IRD 1020.1

Satronic

IRD 1020.1

Satronic

IRD 1020.1

Item no.

Light entrance from right

blue

16531

230 Volt

white

1653104

230 Volt

End-on light entrance

blue

16532

230 Volt

white

1653204

230 Volt

blue

16572

115 Volt

blue

16552

230 Volt

(1020.1 D version)

Light entrance from left

blue

16533

230 Volt

Содержание IRD 1020.1

Страница 1: ... 930 DKG 972 DLG 974 976 DMG 970 971 972 973 TFI 812 2 MMI 810 811 812 815 816 962 TMG 740 2 740 3 SGU 930 930i CONSTRUCTIONAL FEATURES The infra red sensor and the pre amplifier are hermetically sealed in glass and along with the electronics form an integrated unit in the flame detector Wiring is by way of a plug connection The sensitivity control and two LED s for indication of the flame signal ...

Страница 2: ... harsh vibration and receives no hard knocks It is necessary for the magnetic IRD M93 flange to be mounted on a flat surface to avoid any mechanical stress which could otherwise damage it COMMISSIONING AND MAINTENANCE During commissioning and after servicing the flame monitoringsystemshouldbecheckedforfaultlessoperation as follows 1 Check that the detector is connected properly Wrong connectionsar...

Страница 3: ...t or faulty wiring b Sensitivity set too low c Detector positioned wrongly receives no light d Detector or viewing window dirty e Defective detector f IRDflangeM93defective cracksorothermechanical defects g wrong IRD flange special magnetic IRD flange M93 is needed IRD 1020 1 Control box type TFI 812 DKG 97 DMG 97 DLG 97 Terminal no 8 8 8 Terminal no 1 1 2 Terminal no 9 9 9 Control box type MMI Te...

Страница 4: ...16533 Mounting flange Flange M93 230V 59093 Sensor cable Plug type 3 wire 0 6 m with tag wire ends 7236001 The above ordering information refers to the standard version Special versions are also included in our product range Specifications subject to change without notice FLICKER DETECTOR IRD 1020 1 VARIANTS 35 3 26 4 5 15 1 48 ø20 5 4 17 14 104 29 50 44 ø13 5 21 8 HOLDER M93 Satronic IRD 1020 1 S...

Отзывы: