14
6.2
Access control function
-
Hold data carrier in the reading range.
-
Acknowledgement.
6.3
Combination disarm / AC function
-
Disarm first (see 6.1).
-
For the AC funciton, hold the IK data carrier for a
in the reading range
-
AC function will automatically be activated after disarming.
third time
or
Operating Manual IK3 Operating unit contactless
Acknowledgement
with AC function:
Authorized
No authorization or
AC function not activated
Ready (green)
Optical
5 sec.
Time-controlled
door release
Acoustical
(signal)
Positive acknowledge.
Negative acknowledge.
Action
No door release
Disarmed
(yellow)
2 sec.
6.4
Learn mode
Learn mode is used for the simple authorization of new data carriers.
In order to start and exit the learn mode, a
is required. This so-called "learn
master key" is a data carrier that is defined exclusively in the system for this purpose.
As long as the learn mode is activated,
can be performed successively.
The "Alarm" indicator is used in the learn mode as an optical acknowledgement signal. It lights up
green, as long as the learn mode is activated. It flashes briefly to acknowledge an action that has
been performed. (s.b.).
The learn mode can only be activated in a
If an action cannot be performed, negative acknowledgement follows!
Firmware:
- IK3 EU BUS-2
from V05.xx
- IK3 EU conventional
from V01.05
Hold the IK learn master key in the reading range
The "Alarm" indicator lights up green
The actions can now be performed.
Hold new IK data carrier in the reading range
"Alarm" indicator flashes 1x
Hold the IK learn master key in the reading range
"Alarm" indicator goes off
"Learn master key"
any number of actions
disarmed state.
Start learn mode
Learn data carrier
Quit learn mode
Required
upward
upward
green
green
green