BATTERY SERVICE
7-8
www.honeywellgenerators.com
Honeywell Portable Electrical Generator Service Manual
7.9 BATTERY SERVICE
To ensure the battery remains charged, it is recom-
mended that the generator is started every three months.
If the generator is stored for more than a year without run-
ning, a battery charger may be required to recharge the
generator battery.
Recommended Battery Replacement: 101536A
To replace battery:
1.
Remove spark plug cap.
2.
Loosen and remove nuts on retaining plate; slide
retaining plate off support rods.
3.
Tip battery slightly forward.
4.
Disconnect the black negative (-) battery lead remov-
ing the bolt and nut.
5.
Disconnect the red positive (+) battery lead removing
the bolt and nut.
6.
Remove the battery.
NOTE:
Dispose of used battery according to guidelines estab-
lished by your local or state government.
7.
Place the new battery in the generator frame.
8.
Connect the red positive (+) battery lead to the posi-
tive (+) post on the battery; install bolt, nut, and boot.
9.
Connect the black negative (-) battery lead to the neg-
ative (-) post on the battery; install bolt, nut, and boot.
10.
Reinstall retaining plate; tighten bolts and nuts.
11.
Reinstall spark plug cap.
Xtreme
XTAX14AHL-BS
Yuasa
12N14-3A
TABLE 7-6.
Replacement Battery Equivalents to 101536A