Product Installation Document

1 Overview

These Honeywell Rack Mount CCTV power supplies will provide 24 VAC power distributed via 16 circuits for powering 
CCTV cameras and other video equipment.  Each circuit will be fuse protected at 3.0A, or PTC protected at 2.5A.  Fuses 
are accessible directly through the front panel by removing six screws.

2 Specifications

Input:  117VAC, 60Hz, 2A.

Output:  8A @ 24VAC (200VA).

Maximum current rating:
– HPR2416UL:  any output, 3A; total supply, 8A @ 24VAC**.
– HPR2416CBUL:  any output, 2.5A*; total supply, 8A @ 24VAC**.

* PTC Protected Class 2 Power Limited Outputs.
** Outputs 1 to 8 provide 4A @ 24VAC (100VA).
** Outputs 9 to 16 provide 4A @ 24VAC (100VA).

16 outputs.

Surge and transient protection.

Transformer has built-in thermal protection.

Indicator Lights:
– Input Power Indicator (1 red):  Illuminated power switch/circuit breaker.
– Output Power LEDs (16 green):  ON indicates that AC is present at the related output circuit.

Overload Protection:
– Input power switch has built-in circuit breaker.
– AC line fuse (5 x 20mm glass).
– Individual output circuits have a glass fuse (5 x 20mm) or resettable PTCs.

– NOTE: To reset a PTC that has experienced an overload or short circuit, switch power off for 5 minutes to allow 

the PTC to reset itself.

Factory installed three-conductor AC line cord.

Unit maintains camera synchronization.

2U rack chassis for use in standard EIA 19” rack.

Removable rear terminal blocks.

Line power rocker switch with built-in circuit breaker indicates power on with red neon lamp.

Designed for quick installation.

Maximum Temperature Range:  32°F to 120°F (0°C to 49°C); for indoor use only

!

WARNING:TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE 
THIS APPLIANCE TO RAIN OR MOISTURE.

For continuous protection against hazard, replace fuses only with exact type and rating.  All 117V wiring should be 
routed so that it cannot touch 24V wiring; minimum spacing 3/8” (0.953cm).  This installation should be made by a 
qualified service person and should confirm to all local codes.  Install in accordance with the National Electrical 
Code.

Содержание HPR2416CBUL

Страница 1: ...utput Power LEDs 16 green ON indicates that AC is present at the related output circuit Overload Protection Input power switch has built in circuit breaker AC line fuse 5 x 20mm glass Individual output circuits have a glass fuse 5 x 20mm or resettable PTCs NOTE To reset a PTC that has experienced an overload or short circuit switch power off for 5 minutes to allow the PTC to reset itself Factory i...

Страница 2: ...y that 117VAC power is present at receptacle Verify that the unit is plugged into the 117VAC power receptacle Verify that the power switch is in the ON RESET position Try resetting the circuit breaker in the power switch by setting to OFF position then back to ON RESET position 2 If none of the green LEDs on faceplate are illuminated while power switch is illuminated Set power switch on back of un...

Страница 3: ...and secure front panel The PTCs on the HPR2416ULCB will reset automatically while power is off Plug power cord into receptacle Set power switch on back of unit to the ON RESET position Figure 1 Power Supply with Front Panel Removed 52992bd1 wmf Continued on next page ...

Страница 4: ...DUCT INSTALLATION DOCUMENT PN 52___ INPUT 117VAC 60Hz 6A OUTPUT 24 VAC 25A OR 28VAC 21 4A COMMERCIAL CLOSED CIRCUIT TELEVISION EQUIPMENT XXXX 8 N P 7 N P 6 N P 5 N P 4 N P 3 N P 2 N P 1 N P 16 N P 15 N P 14 N P 13 N P 12 N P 11 N P 10 N P 9 N P VERIFY OUTPUT VOLTAGE BEFORE CONNECTING DEVICES Circuit 1 Common Common Common Circuit 2 Circuit 3 Power ON OFF Switch Circuit Breaker Field Wiring Termina...

Страница 5: ...ocument P N 52992 A 5 23 06 5 For additional information Visit our website at http www honeywellpower com Contact Technical Support at 1 877 HPP POWR E mail us at hpp_techserv honeywell com Figure 3 Dimesnsions hprdimensions wmf ...