- 8 -
9. Basic settings
overview
If desired, you can modify the 16 basic settings.
Factory settings have a grey background.
Parameters marked with an * are described in more
detail below.
Par.
Sett.
Meaning
1
1
2
3
4
5
6
Language setting
german
English
French
Dutch
Italian
Danish
2
0
1
2
Preset time programs *
Week program 1
"At home all day"
Week program 2 "At home ifor lunch"
Week program 3 "Working half-time"
3
0
1
Backlight display*
Deactivated
activated
4
0
1
Summer/winter time changeover
No automatic changeover
automatic changeover
5
0
30
...
90
Duration of the window function *
Window function not active
Valve opens at the latest after 30 minutes
...
Valve opens at the latest after 90 minutes
6
0.5
...
3.0
Sensitivity of the window function during
dropping room temperature *
0.5 (sensitive)
...
3.0 (less sensitive)
Factory setting:
0.8
7
0.1
...
3.0
Sensitivity of the window function during
rising room temperature *
0.1 (sensitive)
...
3.0 (less sensitive)
Factory setting:
0.3
8
0
1
Setting the valve stroke *
Standard valve stroke
Full-stroke mode
9
0
1
temperature representation in the display *
Set/programmed temperature
(setpoint
temperature)
Measured room temperature
Par.
Sett.
Meaning
10
16
17
...
30
Upper temperature limit
The room temperature cannot be set higher
than the specified upper temperature limit
(HI LIMIT).
Factory setting:
30 °C
11
5
6
...
15
Lower temperature limit
The room temperature cannot be set lower
than the specified lower temperature limit
(LOW LIMIT).
Factory setting:
5 °C
12
0
1
2
optimisation function *
no optimisation
Optimum start
Optimum start/stop
13
3
...
-3
temperature offset *
To adjust the temperatures measured by the
radiator controller and in the room
Factory setting:
0 °C
14
0
1
2
Battery type
alkaline
Lithium
NiMH (accumulator chargeable)
15
0
1
Display of the valve position *
no display of the valve position
Brief display of the valve position
16
0
1
Restore to factory setting
no reset
Reset to factory setting.
Description of the parameters
Parameter 2 –
Selecting the preset time programs
•
Week program 1
(factory setting, 2 switching points)
:
Mo – Su at home all day
This time program is described in Section 5.
•
Week program 2
(6 switching points):
Mo – Fr at home in the lunch break
Sa – Su like Week program 1
20 °C
16 °C
2
3 4
5
1
6
Conserve
Heating
Heating
22 °C
Switching points