HH490 User Guide
83
Off
Codabar Start/Stop Characters
Start/Stop characters identify the leading and trailing ends of the barcode. You
may either transmit, or not transmit Start/Stop characters.
Default
=
Don’t
Transmit
.
Transmit
* Don’t Transmit
Codabar Check Character
Codabar check characters are created using different “modulos.” You can
program the scanner to read only Codabar barcodes with Modulo 16 check
characters.
Default
=
No Check Character.
No Check Character indicates that the scanner reads and transmits barcode
data with or without a check character.
When Check Character is set to Validate and Transmit, the scanner will only read
Codabar barcodes printed with a check character and will transmit this character
at the end of the scanned data.
When Check Character is set to Validate, but Don’t Transmit, the unit will only
read Codabar barcodes printed
with
a check character but will not transmit the
check character with the scanned data.
* No Check Character
Validate Modulo 16, but Don’t
Transmit
Содержание HH490
Страница 1: ...HH490 Area Imaging Scanner User Guide ...
Страница 14: ...xiv HH490 User Guide ...
Страница 94: ...80 HH490 User Guide Single Scan Data Format 2 Single Scan Data Format 3 ...
Страница 158: ...144 HH490 User Guide ...
Страница 210: ...196 HH490 User Guide 1 2 3 4 5 6 7 8 9 10 5V power Data Data Cable shield Supply ground USB 10 Pin Modular Plug ...
Страница 226: ...212 HH490 User Guide PROGRAMMING CHART 0 1 2 3 4 5 6 7 8 9 ...
Страница 228: ...214 HH490 User Guide Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com HH490 EN UG 01 REV A 02 21 ...