164
HH1800 User Guide
group. For example, all RS232 configuration settings are identified with a Tag
of
232
.
SubTag
A 3 character case-insensitive field that identifies the desired menu command
within the tag group. For example, the SubTag for the RS232 baud rate is
BAD
.
Data
The new value for a menu setting, identified by the Tag and SubTag.
Storage
A single character that specifies the storage table to which the com- mand is
applied. An exclamation poin
t (!) performs the command’s operation on the
device’s volatile menu c
onfiguration table. A period (.) performs the
command’s operation on the device’s non
-volatile menu configuration table.
Use the non-volatile table only for semi- permanent changes you want saved
through a power cycle.
Query Commands
Several special characters can be used to query the device about its settings.
^
>
What is the default value for the setting(s).
What is the PAP sub command.
Note:
When using the
>
, all other commands will return NAK.
?
*
What is the device’s current value for the setti
ng(s).
What is the range of possible values for the setting(s). (The device’s response
uses a dash (-) to indicate a continuous range of values. A pipe (|) separates
items in a list of non-continuous values.)
:Name: Field Usage (Optional)
This command returns the query information from the scanner.
Содержание HH1800
Страница 1: ...HH1800 Area Imaging Scanner User Guide ...
Страница 14: ...xiv HH1800 User Guide ...
Страница 94: ...80 HH1800 User Guide RFID TBD ...
Страница 158: ...144 HH1800 User Guide ...
Страница 210: ...196 HH1800 User Guide 1 2 3 4 5 6 7 8 9 10 5V power Data Data Cable shield Supply ground USB 10 Pin Modular Plug ...
Страница 226: ...212 HH1800 User Guide PROGRAMMING CHART 0 1 2 3 4 5 6 7 8 9 ...