T8411R ELECTRONIC HEAT PUMP THERMOSTAT

68-0185—2

2

ORDERING INFORMATION

When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the 

TRADELINE® Catalog or price sheets for complete ordering number.

If you have additional questions, need further information, or would like to comment on our products or services, please write or 

phone:

1.

Your local Home and Building Control Sales Office (check white pages of your phone directory).

2.

Home and Building Control Customer Relations

Honeywell, 1885 Douglas Drive North

Minneapolis, Minnesota 55422-4386 (800) 328-5111

In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9.

International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, 

Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.

SPECIFICATIONS

IMPORTANT

The specifications given in this publication do not 

include normal manufacturing tolerances; therefore, 

an individual unit might not exactly match the listed 
specifications. Also, this product is tested and cali-

brated under closely controlled conditions, and some 

minor differences in performance can be expected if 
those conditions are changed.

T8411R Standard model includes a thermostat, wallplate (for 
wiring and mounting thermostat) and owner’s guide. 

T8411R TRADELINE® model includes a thermostat, wallplate 
(for wiring and mounting thermostat) and owner’s guide. 

Power: 

T8411R: 24 Vac nominal, 18 to 30 Vac, 50/60 Hz.

Electrical Ratings:

First Stage Heating: 0.02 to 1.5A run; 7.5A inrush.
Second Stage Heating: 0.02 to 1.5A run; 3.5A inrush.

Cooling: 0.02 to 1.5A run; 7.5A inrush.

Fan: 0.02 to 0.5A run; 2.5A inrush.
Emergency Heat Output (E): 0.02 to 1.5A run; 3.5A inrush.

Heating Changeover Valve (B): 0.02 to 0.5A run; 2.5A inrush.

Cooling Changeover Valve (O): 0.02 to 0.5A run; 2.5A inrush.
Emergency Heat Indicator (L): 0.02 to 0.5A run; 2.5A inrush.

Temperature Adjustment: 

Setpoint is adjusted by using the 

 or 

 keys. One press changes the setpoint one 

degree; pressing and holding changes the setpoint sev-

eral degrees. 

Temperature Setting Range: 

40°F to 99°F (4°C to 39°C).

Ambient Temperature Range: 

30°F (-1°C) to 110°F (43°C).

Shipping Temperature Range:

 -

20°F (-29°C) to 120°F (49°C).

Operating Relative Humidity: 

5% to 90% RH, noncondens-

ing.

Cycle Rates (at 50% Load):

First Stage Heating: Fixed at 3 cph.
Second Stage Heating: Selectable at 3, 6 or 9 cph. 

Cooling: Fixed at 3 cph.

Finish:

T8411R TRADELINE®: Taupe finish.

T8411R Standard Models: Premier White® finish and only 

available in builder packs of 20.

Accessory:

Universal Cover Plate available separately (for covering 

wall marks): 7 3/8 in. (188 mm) x 5 3/4 in. (146 mm) 

Order part no. 209649A (taupe color).

Dimensions: 

See Fig. 1.

Fig. 1. T8411R Thermostat dimensions in in. (mm).

Em Ht     Aux Ht

Set

Room  

M18576

FAN

SYSTEM

Auto On

Cool   Off   Heat  Em. Ht.

5-1/2 (140)

1-3/16

(55)

3-1/2

(89)

2-3/8

(70)

THERMOSTAT

4-3/8 (111)

WALLPLATE

THERMOSTAT

AND WALLPLATE

3-5/16 (84)

Содержание HEAT PUMP THERMOSTAT T8411R

Страница 1: ...in a variety of locations Keys are located by the display for easy access Fan and system switches are located on the lower edge to eliminate accidental setting changes Easy installation setup and self test saves installer time and increases their productivity Manual changeover from heat to cool eliminates unexpected system operation F or C temperature display for added model flexibility Selectable...

Страница 2: ...1R TRADELINE model includes a thermostat wallplate for wiring and mounting thermostat and owner s guide Power T8411R 24 Vac nominal 18 to 30 Vac 50 60 Hz Electrical Ratings First Stage Heating 0 02 to 1 5A run 7 5A inrush Second Stage Heating 0 02 to 1 5A run 3 5A inrush Cooling 0 02 to 1 5A run 7 5A inrush Fan 0 02 to 0 5A run 2 5A inrush Emergency Heat Output E 0 02 to 1 5A run 3 5A inrush Heati...

Страница 3: ...on Install the thermostat about 5 ft 1 5m above the floor in an area with good air circulation at average room temperature See Fig 2 Do not install the thermostat where it can be affected by drafts or dead spots behind doors and in corners hot or cold air from ducts radiant heat from the sun or appliances concealed pipes and chimneys unheated uncooled areas such as an outside wall behind the therm...

Страница 4: ...ate and con nect the system wires See Fig 4 2 Securely tighten each terminal screw 3 Push the excess wire back into the hole 4 Plug the hole with nonflammable insulation to prevent drafts from affecting the thermostat Mounting Thermostat to Wallplate 1 Engage the tabs at the top of the thermostat and wall plate 2 Swing down the thermostat and press the lower edge of the thermostat onto the wallpla...

Страница 5: ... TERMINALS SYSTEM SWITCH HEAT OFF COOL R W2 L B O Y EM HT W1 E AUXILARY HEAT RELAY CHANGEOVER VALVE HEAT CHANGEOVER VALVE COOL COMPRESSOR CONTACTOR COMPRESSOR CONTACTOR HEAT FAN RELAY RELAY EMERGENCY HEAT RELAY G C THERMOSTAT LOGIC THERMISTOR SENSOR POWER SUPPLY ON AUTO STAGE 2 RELAY STAGE 1 RELAY FAN SWITCH M11333A 3 3 M18577 SYSTEM Cool Off Heat Em Ht Auto On FAN DASHED LINES INDICATE TABS ON BA...

Страница 6: ...heating load Set Temperature Setpoint NOTE Temperature setpoint range is 40 to 99 F 4 to 39 C The temperature setpoint and the room temperature are shown separately on the display The indicator points to Set when the temperature setpoint is displayed and to Room when the room temperature is displayed To set temperature setpoint 1 Select Heat or Cool by sliding the SYSTEM switch in the lower right ...

Страница 7: ... displayed A typical example is shown but CC varies by model This informa tion is for factory use only 10 Press to save all changes exit installer setup mode and return to normal operation NOTE After exiting installer setup mode change the set point to the desired room temperature OPERATION The T8411R Thermostat provides two stage heat and one stage cool temperature control with proportional plus ...

Страница 8: ...ting and cooling Table 1 Sequence of Operations a The O terminal is powered continuously in cooling the B terminal is powered continuously in heating and the L terminal is powered continuously in emergency heat as a function of the system switch position even without a call for heat or cool CHECKOUT Heating 1 Slide the SYSTEM switch to Heat and the FAN switch to Auto 2 Press and hold the s key to ...

Страница 9: ... THERMOSTAT PARTIAL DISPLAY INOPERATIVE THERMOSTAT SEE THE SETTINGS AND ADJUSTMENTS SECTION FOR INSTRUCTIONS ON INSTALLER SETUP MODE STILL IN INSTALLER SETUP MODE RECONFIGURE THE DISPLAY SEE SETTINGS AND ADJUSTMENTS SECTION TEMPERATURE DISPLAY IS INCORRECT THERMOSTAT IS CONFIGURED FOR F OR C DISPLAY CHECK THAT C TERMINAL IS CONNECTED TO THE SYSTEM TRANSFORMER CHECK POWER TO HEATING AND COOLING EQU...

Страница 10: ...68 0185 2 10 ...

Страница 11: ...11 68 0185 2 ...

Страница 12: ...ilding Control Home and Building Control Honeywell Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 Printed in U S A on recycled paper containing at least 10 post consumer paper fibers ...

Отзывы: