6

Every 1 to 4 Months
(Depending on Water Quality)

WARNING

Voltage Hazard.
Can cause electrical shock and
equipment damage.
Disconnect power and shut off water
supply before installing or servicing.

IMPORTANT

Never oil any part of the humidifier.

Use the following procedure to clean your
Honeywell humidifier:

1. Unplug the humidifier and fan control.
2. Disconnect the wires from the humidity

control external screw terminals.

3. Turn off the water supply.
4. Disconnect the water feed tubing at the

float valve.

5. Disconnect the overflow at the humidi-

fier.

IMPORTANT

Allow water to cool before
continuing.

6. Use a quarter and very slowly turn the

automatic flushing timer indicator
clockwise. This will activate the drain
valve and allow water to flow from the
humidifier reservoir to the drain.

7. Remove the humidifier from the

mounting.

8. Use running tap water to flush loose

minerals from the reservoir.

9. Carefully rub minerals off of the float,

heater and safety float switch.

NOTE:

Steel wool or other scouring
pads can be used on the
reservoir walls and other
parts.

10. Remove the valve arm by pulling out

the cotter pin attachment. Inspect the
arm for mineral buildup and deteriora-
tion.

NOTES: Replace the float valve when

it shows any signs of deterio-
ration.

The float valve should shut off
the water at 2-3/8 in. (60 mm).

11. Reset the water level:

CAUTION

Flooding Hazard.
Inadequate support of the float
arm can lead to valve seat damage
resulting in water leakage.
Support the float arm during adjust-
ment.

a.

Set the humidifier reservoir on a
level surface.

b.

Attach the water feed line and
allow the unit to fill until the float
valve shuts off the incoming flow
of water. The water level should
be between 2-1/4 in. (57 mm)
and 2-1/2 in. (64 mm) deep. If
water level is correct, skip to
step 12.

c.

Adjust the water level in small
increments. Raise the water level
by pushing down on the center of
the float arm. Lower the water
level by pressing the float down
with one hand and pulling up on
the center of the float arm with
the other hand.

TURN CLOCKWISE VERY SLOWLY

SLOT FOR COIN

COIN

M10552

Содержание HE420A

Страница 1: ... U S Registered Trademark Copyright 1998 Honeywell Inc All Rights Reserved OWNER S GUIDE 69 1112 1 HE420A B and HE460A B Steam Power Humidifiers ...

Страница 2: ...hroats and irritated nasal passages that aggravate allergies and asthma You ve also taken the first step to stopping the zapping created by walking on your carpet and touching your TV computer metal door knob or your pet You can even put away your glue bottle because your furniture and woodwork will stop drying out Congratulations You have just made a great investment in your home comfort ...

Страница 3: ...69 1112 1 TABLE OF CONTENTS Operating Your Humidifier 4 How Your Humidifier Works 5 Maintaining Your Humidifier 5 Checking Your Humidifier Operation 7 Troubleshooting Your Humidifier 8 Adding Perfect Climate for Comfort and Convenience 9 Warranty 10 ...

Страница 4: ...ll H1008 Automatic Humidity Control with HumidiCalc Software The automatic humidity control is mounted in the return air duct where it can be exposed to the air stream of the return air The HumidiCalc Software inside your automatic humidity control is designed to automatically adjust the humidity level based on indoor temperature and humidity inferred or measured outdoor temperature and the settin...

Страница 5: ...able so you may be able to lower your thermostat heating setpoint and save money on your heating fuel bills The end result is that your humidifier gives you a comfortable environment that is also energy efficient MAINTAINING YOUR HUMIDIFIER A regular maintenance program prolongs the life of your humidifier and provides a more comfortable home Frequency of cleaning depends on the condition of your ...

Страница 6: ...ub minerals off of the float heater and safety float switch NOTE Steel wool or other scouring pads can be used on the reservoir walls and other parts 10 Remove the valve arm by pulling out the cotter pin attachment Inspect the arm for mineral buildup and deteriora tion NOTES Replace the float valve when it shows any signs of deterio ration The float valve should shut off the water at 2 3 8 in 60 m...

Страница 7: ...r startup or maintenance use the following steps to check the humidifier operation 1 Turn on the humidifier water supply 2 Be sure the humidifier has power and plug in the humdifier 3 Turn the H908A Convertible Humidity Control to the highest setting or the H1008A Automatic Humidity Control to the Test position The underwater heater starts to heat the reservoir water NOTE The H1008A Automatic Humi...

Страница 8: ...ctor Rapid air changes Drafts cold air is dry and is an added load for the humidifier Keep doors and windows closed Close fireplace damper when not in use Keep exhaust fan running time to a minimum Seal around doors and windows High humidity Condensation on walls Turn off the humidity control and water until condensation is completely evaporated Heavy condensation on windows Turn humidity control ...

Страница 9: ...ONTROL HONEYWELL CHRONOTHERM lV PROGRAMMABLE THERMOSTAT Adding Perfect Climate CONTROLS FOR COMFORT AND CONVENIENCE 1 Honeywell Perfect Climate Comfort Center controls or Chronotherm IV Programmable Thermostats 2 Honeywell F35 media air cleaner or F50 electronic air cleaners 3 Honeywell humidity controls 4 Honeywell humidifiers 5 Honeywell home ventilation systems Describing Perfection The most co...

Страница 10: ...of a consumer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some states do not allow the exclusion or limi...

Страница 11: ...HE420A B AND HE460A B STEAM POWER HUMIDIFIERS 11 69 1112 1 ...

Страница 12: ...ited Honeywell Limitée 155 Gordon Baker Road North York Ontario M2H 3N7 www honeywell com yourhome 69 1112 1 J S Rev 5 98 Home and Building Control Honeywell Inc Honeywell Plaza P O Box 524 Minneapolis MN 55408 0524 Printed in U S A on recycled paper containing at least 10 post consumer paper fibers ...

Отзывы: