background image

 
 

 

 

Performance Series Cameras

Performance Series HQA HDZP30XD4  

30x Zoom IR PTZ Dome Camera 

Quick Start Guide 

 

Cautions and Warnings 

 

CAUTION 

 

Installation and servicing should be performed only by qualified and 

experienced technicians to conform to all local codes and to maintain your warranty

 

CAUTION

  

To ensure compliance with electrical safety standards, NRTL-approved 

Class 2 power adaptors are required. 

CAUTION

  

To comply with EN 50130-4 requirements, a UPS should be employed when 

powering the camera from 24 V AC. 

CAUTION

  

IR emitted from this product. Do not view directly with optical instruments 

(magnifiers). Do not stare directly into the lamp at a distance of less than 3.3 ft (1 m). 

CAUTION

  

Risk of explosion if battery is replaced by an incorrect type. Dispose of used 

batteries in accordance with local laws. 

FCC Statement of Compliance 

Information to the User: 

This equipment has been tested and found to comply with the limits for a 

Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference when the equipment is operated in a 

commercial environment. This equipment generates, uses, and can radiate radio frequency energy 

and, if not installed and used in accordance with the instruction manual, may cause harmful 

interference to radio communications. Operation of this equipment in a residential area is likely to 

cause harmful interference in which case the user will be required to correct the interference at his 

own expense. 

Note:

 

Changes or modifications not expressly approved by the party responsible for compliance 

could void the user’s authority to operate the equipment. 

This Class A digital apparatus complies with Canadian ICES-003. 

Cet appareil numérique de la Classe A est conforme à la norme NMB-003 du Canada. 

Manufacturer’s Declaration of Conformance 

North America

     The equipment supplied with this guide conforms to UL 60950-1 and CSA C22.2 

No. 60950-1. 

Europe

     The manufacturer declares that the equipment supplied with this guide is compliant with 

the European Parliament and Council Directive on the Restrictions of the use of certain Hazardous 

Substances in electrical and electronic equipment (2011/65/EU), General Product Safety Directive 

(2001/95/EC) and the essential requirements of the EMC Directive (2014/30/EU), conforming to 

the requirements of standards EN 55032 for emissions, EN 50130-4 for immunity, and EN 60950-

1 for electrical equipment safety. 

This is a Class A product. In a domestic environment this product may cause radio interference in 

which case the user may be required to take adequate measures.  

Waste Electrical and Electronic Equipment (WEEE) 

 

Correct Disposal of this Product 

(applicable in the European Union and other European 

countries with separate collection systems). 

This product should be disposed of, at the end of its useful life, as per applicable local 

laws, regulations, and procedures.

 

Safety Instructions 

Before installing or operating the unit, read and follow all instructions. After installation, retain 

the safety and operating instructions for future reference. 

1.

 

HEED WARNINGS 

- Adhere to all warnings on the unit and in the operating instructions. 

2.

 

INSTALLATION 

 

Install in accordance with the manufacturer’s instructions. 

 

Installation and servicing should be performed only by qualified and experienced 
technicians to conform to all local codes and to maintain your warranty. 

 

Any wall or ceiling mounting of the product should follow the manufacturer’s 
instructions and use a mounting kit approved or recommended by the manufacturer. 

3.

 

POWER SOURCES 

- This product should be operated only from the type of power 

source indicated on the marking label. 

4.

 

HEAT 

- Situate away from items that produce heat or are heat sources such as radiators, 

heat registers, stoves, or other products (including amplifiers). 

5.

 

MOUNTING SYSTEM 

- Use only with a mounting system recommended by the 

manufacturer, or sold with the product. 

6.

 

ATTACHMENTS 

- Do not use attachments not recommended by the product 

manufacturer as they may result in the risk of fire, electric shock, or injury to persons. 

7.

 

ACCESSORIES

 - Only use accessories specified by the manufacturer. 

8.

 

CLEANING 

- Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for 

cleaning. 

9.

 

SERVICING

 - Do not attempt to service this unit yourself as opening or removing covers 

may expose you to dangerous voltage or other hazards. Refer all servicing to qualified 
service personnel. 

10.

 

REPLACEMENT PARTS - 

When replacement parts are required, be sure the service 

technician has used replacement parts specified by the manufacturer or have the same 
characteristics as the original part. Unauthorized substitutions may result in fire, 

electric shock or other hazards. Using replacement parts or accessories other than the 
original manufacturers may invalidate the warranty.

 

Before You Begin 

Check that you have received all of the items listed below: 

Module 

Accessories 

 

 

 

 

 

 

 
 
 

 

 

 

 

 

 

 

HDZP30XD4

 

Wall Mount

 

Pendant 

Adaptor

 

Wrench

 

Waterproof 

Tape

 

Quick Start 

Guide 

Note

: Remove the protective cover bag and tape from the camera body before installation.  

Configuring the DIP Switches 

Remove the panel at the rear of the camera and familiarize yourself with the camera’s 
DIP switches. 

 

 
Use the following ON/OFF positions as a reference when setting the camera address, 
baud rate, or video format: 
 

  

 
  

 
 

 

 

Setting the Camera Address (RS485 Only) 

If you are installing more than one PTZ camera in an 
RS485 wiring system, you will need to assign each 
camera a unique address.  
The camera address is set using the 8-position DIP 
switch. Use the following table as a reference:  
 

Address  1 

OFF  OFF 

OFF  OFF  OFF  OFF  OFF  OFF 

ON 

OFF 

OFF  OFF  OFF  OFF  OFF  OFF 

OFF  ON 

OFF  OFF  OFF  OFF  OFF  OFF 

ON 

ON 

OFF  OFF  OFF  OFF  OFF  OFF 

OFF  OFF 

ON 

OFF  OFF  OFF  OFF  OFF 

ON 

OFF 

ON 

OFF  OFF  OFF  OFF  OFF 

OFF  ON 

ON 

OFF  OFF  OFF  OFF  OFF 

ON 

ON 

ON 

OFF  OFF  OFF  OFF  OFF 

OFF  OFF 

OFF  ON 

OFF  OFF  OFF  OFF 

 

254 

OFF  ON 

ON 

ON 

ON 

ON 

ON 

ON 

255 

ON 

ON 

ON 

ON 

ON 

ON 

ON 

ON 

 
For example, if you want to set the camera address to 6, set switches 2 and 3 to ON, and 
set switches 1, 4, 5, 6, 7, and 8 to OFF. 

 

 

ON

Switch is 
set to ON 

ON

Switch is 
set to OFF 

Switches 1, 2, and 3 are 
set to ON, and switch 4 
is set to OFF.

 

Camera back cover 

Address 

Baud rate/ 

Video format 

Note:

  This unit supports 

HQA

Pelco-D

, and 

Pelco-P

 protocols only. 

The protocol is recognized automatically so it does not need to be set 
at the camera. However, the protocol does need to be set at the DVR. 

120-ohm termination 

resistor 

Отзывы: