background image

Honeywell

 

|

 

Performance Series

 

 

Performance Series HQA HDP302DQI 

1080p IR PTZ Dome Camera 

Quick Start Guide 

 

Cautions and Warnings 

 

 

 

 

 

 

 

 

 

WARNING 

 

Installation and servicing should be performed only by qualified and 

experienced technicians to conform to all local codes and to maintain your warranty. 

WARNING

  

To ensure compliance with electrical safety standards, CSA Certified/UL 

Listed Class 2 power adaptors are required.  

WARNING

  

IR emitted from this product. Do not view directly with optical instruments 

(magnifiers). Do not stare directly into the lamp at a distance of less than 3.3 ft (1 m). 

FCC Statement of Compliance 

Information to the User: 

This equipment has been tested and found to comply with the 

limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are 
designed to provide reasonable protection against harmful interference when the 
equipment is operated in a commercial environment. This equipment generates, uses, 
and can radiate radio frequency energy and, if not installed and used in accordance with 
the instruction manual, may cause harmful interference to radio communications. 

Operation of this equipment in a residential area is likely to cause harmful interference 
in which case the user will be required to correct the interference at his own expense. 

Note:

 

Changes or modifications not expressly approved by the party responsible for 

compliance could void the user’s authority to operate the equipment. 

This Class A digital apparatus complies with Canadian ICES-003. 

Cet appareil numérique de la Classe A est conforme à la norme NMB-003 du Canada. 

Manufacturer’s Declaration of Conformance 

The manufacturer declares that the equipment supplied with this guide is compliant 
with the European Parliament and Council Directive on the Restrictions of the use of 
certain Hazardous Substances in electrical and electronic equipment (2011/65/EU), 
General Product Safety Directive (2001/95/EC) and the essential requirements of the 
EMC Directive (2014/30/EU), conforming to the requirements of standards EN 55022 
for emissions, EN 50130-4 for immunity, and EN 60950-1 for electrical equipment 

safety. 

CAUTION

 This is a Class A product. In a domestic environment this product may cause 

radio interference in which case the user may be required to take adequate measures.  

WARNING

 To comply with EN50130-4 requirements, a UPS should be employed when 

powering the camera from 24 VAC. 

Waste Electrical and Electronic Equipment (WEEE) 

 

Correct Disposal of this Product 

(applicable in the European Union and 

other European countries with separate collection systems). 

This product should be disposed of, at the end of its useful life, as per 
applicable local laws, regulations, and procedures.

 

Safety Instructions 

Before installing or operating the unit, read and follow all instructions. After 

installation, retain the safety and operating instructions for future reference. 

1.

 

HEED WARNINGS 

- Adhere to all warnings on the unit and in the operating 

instructions. 

2.

 

INSTALLATION 

 

Install in accordance with the manufacturer’s instructions. 

 

Installation and servicing should be performed only by qualified and 

experienced technicians to conform to all local codes and to maintain 
your warranty. 

 

Do not install indoor rated models in outdoor locations. 

 

Any wall or ceiling mounting of the product should follow the manufacturer’s 

instructions and use a mounting kit approved or recommended by the 
manufacturer. 

3.

 

POWER SOURCES 

- This product should be operated only from the type of power 

source indicated on the marking label. 

4.

 

HEAT 

- Situate away from items that produce heat or are heat sources such as 

radiators, heat registers, stoves, or other products (including amplifiers). 

5.

 

MOUNTING SYSTEM 

- Use only with a mounting system recommended by the 

manufacturer, or sold with the product. 

6.

 

ATTACHMENTS 

- Do not use attachments not recommended by the product 

manufacturer as they may result in the risk of fire, electric shock, or injury to 
persons. 

 

7.

 

ACCESSORIES

 - Only use accessories specified by the manufacturer. 

8.

 

CLEANING 

- Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for 

cleaning. 

9.

 

SERVICING

 - Do not attempt to service this unit yourself as opening or removing 

covers may expose you to dangerous voltage or other hazards. Refer all servicing to 
qualified service personnel. 

10.

 

REPLACEMENT PARTS - 

When replacement parts are required, be sure the 

service technician has used replacement parts specified by the manufacturer or 

have the same characteristics as the original part. Unauthorized substitutions may 
result in fire, electric shock or other hazards. Using replacement parts or 
accessories other than the original manufacturers may invalidate the warranty. 

 

CAUTION

 

Risk of explosion if Battery is replaced by an incorrect type. Dispose of 

used batteries in accordance with local laws.

 

Before You Begin 

Open the box and check: 

Module 

Accessories 

 

 

 

 

 

 

 
 
 

 

 

 

 
 
 

 

HDP302DQI

 

Wall Mount

 

Pendent 

Adaptor

 

Wrench

 

Waterproof 

Tape

 

Quick Start 

Guide 

 

Note

: Rotate and remove the protective cover bag and tape from the camera body before 

the installation.  

Dip Switches 

Take a minute to familiarize yourself with the camera’s switches, as shown in the figures 
below. When setting the dip switches for either the address setting, baud rate setting, or 
parity check, use the following ON/OFF positions as a reference: 

 

 

 

 
 
 

  

 

Please note the intelligent speed dome can self-adapt PELCO-D, PELCO-P and 

industrial standard protocol. The control protocol doesn’t have to be set via the dip 

switches.  

Address Setting 

Assign an Address number to a Performance Series PTZ 
dome camera if there is more than one camera in the same 
network. The camera’s Address can be set by using the 8-bit 
Address dip switch, which is located on the camera body’s 

back as shown in the figure above. If the camera’s Address 
number is 6, for example, the Address switches SW2 and 
SW3 should be set to ON, and the rest should be set to OFF (see the Address numbering 
table below). Address numbers 0–8, 254 and 255 are listed in the table below.  

Note:

 Cameras in the same network should not be given with the same camera Address. 

Otherwise, a communication conflict error may occur. 

ON

CAUTION:  TO REDUCE  THE RISK OF ELECTRIC  SHOCK, 
DO  NOT REMOVE  COVER  (OR BACK). 
NO  USER SERVICEABLE  PARTS  INSIDE. 
REFER  SERVICING  TO QUALIFIED  SERVICE  PERSONNEL

.

 

Switch is 
Set to ON 

ON

Switch is 
Set to OFF 

Means switches 1, 
2, and 3 are set to 
ON, and switch 4 is 
set to OFF.

 

Camera back cover 

Address 

Baud rate/Parity 

RISK OF ELECTRIC SHOCK

DO NOT OPEN

Содержание HDP302DQI

Страница 1: ...nicians to conform to all local codes and to maintain your warranty Do not install indoor rated models in outdoor locations Any wall or ceiling mounting of the product should follow the manufacturer s instructions and use a mounting kit approved or recommended by the manufacturer 3 POWER SOURCES This product should be operated only from the type of power source indicated on the marking label 4 HEA...

Страница 2: ...ht of the camera and the mount at least 27 72 lb 12 57 kg Configuring the PTZ Dome Camera When the camera is connected to a Performance Series HQA DVR you can configure the camera s settings using the camera s on screen display OSD menu Note The DVR s PTZ protocol must be set to HQA for up the coax control of the OSD menu To configure the camera settings 1 Verify that the camera is connected to th...

Страница 3: ...E RECOVERY OFF 5M 15M 30M 1H 2H WDR SETTING WDR MODE ON OFF DAY NIGHT SETTING DAY NIGHT LIGHT NIGHT DAY AUTO SENSITIVITY HIGH MID LOW FOCUS SETTING FOCUS MODE AUTO MANUAL SEMIAUTO FOCUS LIMIT AUTO 10CM 1M 2M 3M 5M AF SENSITIVITY HIGH MID LOW IR CORRECTION ON OFF AUTO IMAGE ADJUST BRIGHTNESS 0 100 SATURATION 0 100 CHROMA SUPPRESS 1 4 GAMMA 1 16 CONTRAST 0 100 STYLE SOFT NATURAL STANDARD BACK EXIT D...

Страница 4: ... 0 2 4888 051 Honeywell Security España Avenida de Italia n 7 2a planta C T Coslada 28821 Coslada Madrid Spain www honeywell com security es 34 902 667 800 Honeywell Security Россия и СНГ 121059 Moscow UI Kiev 7 Russia www honeywell com security ru 7 495 797 93 71 Honeywell www honeywell com security 1 800 323 4576 North America only https www honeywellsystems com ss techsupp index html Document 8...