background image

CLEANING CONTINUED

• Fill the Reservoir Base with one 8-oz. (250ml) cup of undiluted white vinegar. Let
solution stay for 20 minutes.

• With vinegar still in the unit, clean all interior surfaces of the base with a soft
brush or cloth to remove scale.

• Rinse Reservoir Base thoroughly with clean, warm water to remove scale and
cleaning solution.

S T E P   T W O :   W E E K LY   D I S I N F E C T I N G   ( W A T E R   T A N K ,
R E S E R V O I R   B A S E )  

• Empty the water tank. Refill with 1 teaspoon of chlorine bleach in 1 gallon (4 litres)
water. Let solution stay in the tank 20 minutes, swishing every few minutes to wet 
all surfaces.

• Empty tank after 20 minutes. Rinse with water until bleach smell is gone. 

• Repeat for the Reservoir Base. 

A F T E R   D I S I N F E C T I N G

• Clean all surfaces of the power unit with a dry, soft cloth. 

WARNING:

DO NOT USE

WATER TO CLEAN THE POWER UNIT. THIS MAY DAMAGE THE HUMIDIFIER OR CAUSE
ELECTRIC SHOCK.

• If you have hard water, you may need to clean or change the filter more often. If
the filter is dirty, rinse it under cold tap water and turn the filter upside down
before repositioning in the base. Do not squeeze or wring out pad. Do not soak pad 
in bleach or vinegar. 

When the filter turns dark brown, replace it. For best and proven results always
use Honeywell Cool Moisture filters available from your local store or from
Honeywell.

• Reposition the Filter, Motor Housing and Water Tank.

NOTE: THE FAN MOTOR OF THIS HUMIDIFIER AND THE  COOL MOISTURE FILTER ARE
DESIGNED TO FUNCTION EFFICIENTLY AS A SET. 

USING ANY OTHER FILTER COULD

DAMAGE THE HUMIDIFIER’S MOTOR OR IMPAIR ITS PERFORMANCE.

Содержание HCM-1000 Series

Страница 1: ...OWNER S MANUAL Moisture Control Off High Med Lo w POWER REFILL DESIRED HUMIDITY COOL MOISTURE HUMIDIFIER Models HCM 1000 2000 Series Model HCM 2000 ...

Страница 2: ...than a 120V AC polarized outlet If you are unable to insert the plug fully into the outlet try reversing the plug If the plug should still fail to fit contact an electrician to replace the obsolete outlet DO NOT defeat the safety purpose of the polarized plug 6 A loose fit between the AC outlet and plug may cause overheating of the plug Have a qualified electrician replace the outlet 7 The humidif...

Страница 3: ...he proper moisture level in your home or office with your Honeywell Cool Moisture Humidifier may also Replace needed moisture in furniture Keep indoor plants moist and healthy Eliminate cracking and dryness in wood furniture and fixtures Minimize static electricity H O W D O E S I T W O R K Dry air is pulled through the Cool Moisture system and a quiet fan disperses invisi ble moisture balanced ai...

Страница 4: ...difier Turn the Water Tank upside down so that the fill cap is facing up Fill the Water Tank with COOL tap water Fig 3 Distilled water is not necessary as the water is filtered by the Cool Moisture filter DO NOT USE HOT WATER Replace the fill cap CAUTION WHEN CARRYING THE FILLED WATER TANK PLEASE USE THE HANDLE AND PLACE YOUR OTHER HAND UNDER THE TANK FOR ADDITIONAL SUPPORT Turn Water Tank right s...

Страница 5: ... THE HUMIDIFIER FAN WILL NOT START OR RESTART WHEN YOU SELECT A FAN SPEED THE HUMIDISTAT MAY BE SET TOO LOW MOVING THE HUMIDITY LEVEL KNOB TO A HIGHER SETTING THE LARGEST BLACK DOT BEFORE THE SIGN SHOULD RESTART THE FAN When a comfortable humidity level is reached lower the Moisture Control Humidistat setting slowly by turning the knob clockwise until the fan stops Fig 4 The DESIRED HUMIDITY light...

Страница 6: ...ER OR DAMAGE THE HUMIDIFIER THEREBY HINDERING THE HUMIDIFIER S EFFECTIVENESS DO NOT USE SOAP DETERGENTS OR ABRASIVE CLEANSERS Cleaning involves two steps SCALE REMOVAL and DISINFECTING Be sure to per form these in the proper order to avoid harmful chemical interactions First turn off and unplug the humidifier Then remove the Water Tank by grasping the handle and pulling straight up Fig 6 Lift the ...

Страница 7: ...Reservoir Base A F T E R D I S I N F E C T I N G Clean all surfaces of the power unit with a dry soft cloth WARNING DO NOT USE WATER TO CLEAN THE POWER UNIT THIS MAY DAMAGE THE HUMIDIFIER OR CAUSE ELECTRIC SHOCK If you have hard water you may need to clean or change the filter more often If the filter is dirty rinse it under cold tap water and turn the filter upside down before repositioning in th...

Страница 8: ...rt of the next humidification season Models HCM 1000 Series are rated 0 45 Amps at 120V 60 Hz Models HCM 2000 Series are rated 0 6 Amps at 120V 60 Hz WARNING IF YOU EXPERIENCE A PROBLEM WITH YOUR HUMIDIFIER S POWER UNIT PLEASE SEE THE WARRANTY FOR INSTRUCTIONS PLEASE DO NOT ATTEMPT TO OPEN OR REPAIR THE HUMIDIFIER YOURSELF DOING SO MAY VOID THE WARRANTY AND COULD CAUSE DAMAGE OR PERSONAL INJURY IF...

Страница 9: ...shipping charges or sales tax where applicable NOTE These fit HCM 1000 and HCM 2000 series products Item Item No US Price CAN Price Cool Moisture Replacement Filter HAC 500 14 00 18 90 Digital Humidity Temperature Indicator measures room humidity level HAC 555 19 99 26 98 Water Tank and Fill Cap HCM 1000 series HCM 1000 1 19 99 26 98 Water Tank and Fill Cap HCM 2000 series HCM 2000 1 19 99 26 98 F...

Страница 10: ...ories subject to availability Prices may change without notice CHECK OR MONEY ORDER ENCLOSED NO COD S ACCEPTED R E P L A C E M E N T PA R T S A N D C A R E P R O D U C T S If your local dealer is out of stock Honeywell replacement parts and care products may be ordered directly Fill out the form and mail it along with a check or money order no cash please to Honeywell Inc at the address shown belo...

Страница 11: ...tions or exclusions may not apply to you This warranty gives you specific legal rights and you also may have other rights which vary from jurisdiction to jurisdiction This warranty applies only to the original purchaser of this product from the original date of purchase B At its option Honeywell will repair or replace this product if it is found defective in material or workmanship Defective produ...

Отзывы: