Rev
1.01
11
900.0355
01/06
Function Operations
Synchronization Setting (SYNC)
You can select internal sync mode (
INT
) or line-lock mode
(
LL
).
1.
Use the
Up
and
Down
keys to move the cursor (
) to
the Sync parameter and use the
Right
and
Left
keys to
select line-lock (
LL
) or internal (
INT
).
2.
If
LL
is selected, press
SET
and the
Line Lock
menu
appears. If
INT
is selected, the synchronization mode is
automatically set to internal sync and the menu displays
INT
.
Line-Lock Sync Mode (LL)
The line-lock mode has its own menu for line-lock vertical
phase adjustment. When the vertical phase adjustment menu
appears on the monitor, use the
Right
or
Left
keys to move the
cursor (
) for phase adjustments. If the camera installation is
relocated, check the vertical phase adjustment again since the
AC line phase may be different.
Note
The line-lock (
LL
) sync mode is not available
when the camera operates on DC power.
Shutter Speed Setting (Shutter)
To select electronic shutter speed, you can select either:
•
A manual electronic shutter speed of 1/50 (1/60), 1/120
(1/100), 1/250, 1/500, 1/1000, 1/2000, 1/4000, or 1/10000
seconds.
OR
•
Auto Electronics Shutter (
AES
).
The 1/50 (1/60) sets the shutter to
OFF
. This function is
effective to raise the sensitivity in low light conditions when
OFF
is selected in the Auto Iris Lens field. Move the cursor (
)
to the
Shutter
parameter and select the electronic shutter
speed. The preset values for Shutter (electronic shutter speed)
change by pressing the
Right
or
Left
keys. Selecting
AES
will
have the camera automatically select an appropriate shutter
speed.
Содержание HCD484E