Checking 

 

4. Checking 

 

4.1. System 

check 

 

Adjust the set point of the room unit HCW 80 to 30 °C. 

If the room temperature is >30 °C the relay module 
HC60NG is switched on. 

 

Change the set point of the room unit HCW 80 to 5 °C.  

If the room temperature is <5 °C the relay module 
HC60NG is switched OFF. 

 

4.2. Radio 

transmission 

check 

The room unit HCW 80 can send a test signal to the 
assigned relay module HC60NG in order to test the signal 
strength. 

 

Keep the teach-in button of the HCW 80 pressed for at 
least 15 sec until the red LED of the HCW 80 is OFF. 

The HCW 80 is now in test mode and sends a test signal 
every 5 sec. 
The LED of the HCW80  flashes briefly at every test 
signal the HCW 80 is sending. 

The field strength is indicated by flashing of the red LED of 
the HC60NG (1 = sufficient, 5 = strong). 

 

If the wireless communication is not successful 
optimise the placement of the HCW80

 

 

The test mode is terminated automatically after 
5 min. The test mode can also be terminated by 
removing the batteries or by pressing the teach-
in button. 

 

5. Teach-in 

(single 

devices 

only) 

The teach-in operation is required if the relay module 
HC60NG and the room unit HW80 are not pre-bounded e.g. 
new single devices or product replacement. 

 

5.1.  Assignment to the relay module 

HC60NG 

After the power up of the relay module HC60NG the red 
LED will start to flash at  0,1 sec ON/ 0,9 sec OFF. 
If this is not the case set the HC60NG into the reset mode 
see section “7 Factory reset of relay module HC60NG”. 

 

Press and hold the teach-in button of the HC60NG for  
5 sec to enter into the teach-in mode.

 

The red LED flashing at 0.5 sec ON/0.5 sec OFF 
confirms the teach-in mode has been entered.

 

 

Press the teach-in button of the HCW 80 to send the 
binding signal to the HC60NG. 

The red LED of the HC60NG is switched OFF to confirm 
a successful teach-in operation.  

The teach-in mode is terminated automatically after 5 min. 

 

5.2. Failed 

teach-in 

 

If the teach-in has failed: 

 

See section “5.1 Assignment to the relay module 
HC60NG”.

 

 

Improve the data transfer.

 

 

Improving the data transfer 

 

When selecting the operating site of each device ensure 
that the distance to radio devices such as radio 
headphones, cordless phones, etc. according to the DECT 
standard amounts to at least 1 m. 

 

Do not install the devices over metallic wall connecting 
sockets and at least 30 cm away from the cover of the heat 
generator. 

 

Correct the installation site of the room unit HCW 80 if 
necessary. 

 

6. Communication 

loss 

When the RF communication is lost for a period of 1 h, the 
red LED of the relay module HC60NG is ON to indicate that 
no RF messages have been received during the last hour.

 

When RF communication is re-established the relay module 
HC60NG will automatically return to normal operation mode. 
See chapter “10

 

Help with problems” for possible cause and 

problem solving. 
 

7. 

Factory reset of relay 
module HC60NG 

 

Keep the button of the HC60NG pressed for at least  
15 sec. 

The resetting was successful when the red LED flashes 
rapidly (1/9 ON/OFF). 

 

 

After the factory reset the HC60NG looses the 
communication with the HCW 80.  
See section “5 Teach-in (single devices only)” for 
new teach-in. 

 

Содержание HC60NG

Страница 1: ...Y6630D1007 Wireless Room Thermostat Installation and Operation ...

Страница 2: ......

Страница 3: ...6 EC Waste Electrical and Electronic Equipment directive 9 1 General safety instructions 1 1 Commissioning the relay module HC60NG Danger Danger to life through electric shock Contacts that are open are live Ensure that the device is de energised Have all the work carried out by authorised qualified personnel Observe the valid local regulations during the installation WARNING Insufficient data tra...

Страница 4: ...Boiler Relay module HC60NG Example radiator control Zone 1 Fig 1 Application of the wireless room thermostat 2 1 Pre configured kit Y6630D1007 1 HCW 80 room unit 1 HC60NG relay module 2 AA batteries 1 5 V type LR6 The kit Y6630D1007 is provided pre bounded The room unit HCW 80 is already assigned to the relay module HC60NG The teach in is not required in this kit 2 2 Single provided devices Single...

Страница 5: ...local wiring regulations Observe ambient temperature and current limits see HC60NG wiring label a Burner direct control b Combi boiler c Zone valve d Electric heater e Thermal actuator f Zone valve g Electric actuator h Cooling device Fig 7 Wiring schemes 1 2 2 Fig 8 Closing the terminal and housing cover ...

Страница 6: ...e room unit HCW 80 Place the room unit HCW 80 at the installation site Remove the housing cover of the room unit HCW 80 see Fig 10 1 2 Fig 10 Removing the housing cover Mark the drill holes according to the drilling template see Fig 11 Fig 11 Drilling scheme measurements in mm Drill the holes Screw on the room unit Insert the supplied AA batteries with the correct battery polarity see Fig 12 Fig 1...

Страница 7: ...odule HC60NG Press and hold the teach in button of the HC60NG for 5 sec to enter into the teach in mode The red LED flashing at 0 5 sec ON 0 5 sec OFF confirms the teach in mode has been entered Press the teach in button of the HCW 80 to send the binding signal to the HC60NG The red LED of the HC60NG is switched OFF to confirm a successful teach in operation The teach in mode is terminated automat...

Страница 8: ... 15 the pins are inserted so that the adjustment dial can only be adjusted in the range of 19 C to frost protection lower limit and 19 C to 30 C higher limit around the value 19 C Turn the adjustment dial clockwise until it stops Check whether the adjustment dial is in the position shown in Fig 14 If appropriate put the adjustment back in rotated by 180 until it has the position shown Turn the adj...

Страница 9: ...wall box mounting right an bottom RF RF operation band ISM 868 0 868 6 MHz 1 duty cycle RF communication range 30 m in a residential building environment RF communication technology Short high rate transmissions to minimise air time and avoid collisions Blocking immunity Receiver class 2 ETSI EN300 220 1 version 1 3 1 RF binding method Factory pre bound with the room unit HCW 80 kit Y6630D1007 onl...

Страница 10: ......

Страница 11: ......

Страница 12: ...Armaturen Robinetterie Rubinetterie Bernstrasse 36 CH 4663 Aarburg Oftringen Telefon 062 787 70 00 Fax 062 787 70 01 info robinex ch www robinex ch ROBINEX AG SA ...

Отзывы: