H46C,E HUMIDITY CONTROLLERS
2 X 3 IN
W OOD SCREW S
• KEYHOLES
IN BA CK OF
CASE (2)
- W ALL
SURFACE
Fig. 2. Mounting H46E with two screws.
M7908
WIRING
Disconnect power supply before connecting wiring to
avoid electrical shock or equipment damage. All wiring
must comply with local codes and ordinances. Do not
exceed contact and coil ratings when wiring into the
system.
Connections and Operation
A dehumidistat in combination with the thermostat can be
used to run the air conditioner to control relative humidity
levels. The H46C dehumidistat and thermostat can be
wired in parallel or in series.
Wiring in parallel allows the dehumidistat to indepen
dently control the humidity level, but could cause
overcooling of the home. During unoccupied times, the
homeowner should set the thermostat to a relatively high
setting and control moisture using the dehumidistat.
Wiring in series prevents overcooling but the air
conditioner runs only when both the thermostat and
dehumidistat are calling. During unoccupied times, the
homeowner should set the thermostat to a relatively low
setting and control moisture using the dehumidistat.
H 46 C ,E
H U M ID IT Y C O N T R O LL E R
RISE
P O W E R A (HOT)
S U P P L Y ^ -1 ^
• L 2 ------
-°H h >
/ K
p
L1
D E H U M ID IFIE R
E X H A U S T FAN
O R AIR
C O N D IT IO N E R
M7915
Fig. 4. Typical wiring diagram for H46C,E.
69-1000B-1
2