Configuring Camera Settings
33
Connection
Figure 5-11 Connection Configuration Interface
Table 5-9 Connection Configurations
Parameter
Function
Max
Connection
Displays the maximum number of network connections for the same camera. The
value ranges from
1
to
20
. The maximum number of connections is
20
.
TCP Port
The default setting is
37777
. You can modify this setting as necessary.
UDP Port
The default setting is
37778
. You can modify this setting as necessary.
HTTP Port
The default setting is
80
. You can modify this setting as necessary.
RTSP Port
The default setting is
554
. The RTSP stream query format is:
Main stream
:
rtsp://username:password@ip:port/cam/realmonitor?channel=1&subtype=0
Sub stream
:
rtsp://username:password@ip:port/cam/realmonitor?channel=1&subtype=1
You are required to manually enter the following four items:
Username,
Password, IP
, and
Port
.
IP
: The camera’s IP address.
Port
: The default is
554
. You can leave this field blank if you are using the default
value.
Follow standard RTP protocols. When the encode mode is
MJPEG
, the maximum
supported resolution is 2040×2040.
HTTPS
HTTPS is enabled by default. To disable HTTPS, clear the check box.
HTTPS Port
The default setting is
443
.