98
Granit XP User Guide
Illumination Lights
If you want the illumination lights on while reading a barcode, scan the
Lights On
barcode, below. However, if you want to turn just the lights off, scan the
Lights Off
barcode.
Default = Lights On.
Note:
This setting does not affect the aimer light. The aiming light can be set using
Aimer Delay
The aimer delay allows a delay time for the operator to aim the scanner before the
picture is taken. Use these codes to set the time between when the trigger is pulled
and when the picture is taken. During the delay time, the aiming light will appear,
but the LEDs won’t turn on until the delay time is over.
Default = Off.
* Lights On
Lights Off
1 millisecond
250 milliseconds
500 milliseconds
* Off
(no delay)
Содержание Granit XP 199 i Series
Страница 15: ...Granit XP User Guide xiii Programming Chart 291 ...
Страница 16: ...xiv Granit XP User Guide ...
Страница 18: ...xvi Granit XP User Guide ...
Страница 27: ...Granit XP User Guide 9 Granit XP SR Linear Barcodes and 2D matrix symbol with aiming dot ...
Страница 30: ...12 Granit XP User Guide ...
Страница 56: ...38 Granit XP User Guide ...
Страница 96: ...78 Granit XP User Guide ...
Страница 158: ...140 Granit XP User Guide Single Scan Data Format 1 Single Scan Data Format 2 Single Scan Data Format 3 ...
Страница 222: ...204 Granit XP User Guide ...
Страница 242: ...224 Granit XP User Guide ...
Страница 290: ...272 Granit XP User Guide CCB22 100BT 03N BF Base ...
Страница 296: ...278 Granit XP User Guide ...
Страница 309: ...Granit XP User Guide 291 PROGRAMMING CHART 0 1 2 3 4 5 6 7 8 9 ...
Страница 311: ......
Страница 312: ... Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com 199x EN UG 01 Rev A 6 20 ...