Terminals on a

34440 Mains Interface Board

Terminals on a

Replacement Mains Interface Board

(VSINTM-PCB-UPG)

Installation

Replacement Mains Interface Board

Gent by Honeywell reserves the right to revise this publication from time to time and make changes to the content hereof without
obligation to notify any person of such revisions of changes.

Hamilton Industrial Park, Waterside Road, Leicester LE5 1TN, UK

Website: www.gent.co.uk

Telephone: +44 (0) 116 246 2000

Technical support: www.gentexpert.co.uk

Fax (UK): +44 (0)116 246 2300

4

4188-1005 issue 1_03/11_Replacement Board for 34440 MPI

by Honeywell

At the end of their useful life, the packaging,
product and batteries should be disposed of
via a suitable recycling centre and in
accordance with national or local legislation.

Do not dispose of with your normal household waste.
Do not burn.

WEEE Directive:

At the end of their useful life, the packaging,
product and batteries should be
disposed of via a suitable recycling centre.

24V 2.1Ahr BATTERIES

+

-

-

PB2

S+

Z+ Z-

S-

SECTOR / ZONE1

PB3

S+

Z+ Z-

S-

SECTOR / ZONE2

PB4

S+

Z+ Z-

S-

SECTOR / ZONE3

PB5

S+

Z+ Z-

S-

SECTOR / ZONE4

PB1

0C LC 01 L1 02 L2

LOOP WIRING

L

N

PB6

+

+

-

-

AUX O/P

P3

P7

Replacement Mains Interface Board

(VSINTM-PCB-UPG)

+

N E

L

CONNECTION TO

THE TRANSFORMER

P3

P4

P5

P6

P2

P9

P8

34440 Mains Interface Board

P7

24V DC SUPPLY

FUSED AT 250mA

+ -

2 x 12V 2.1Ahr BATTERIES

+ -

BATTERY

AUX

+

-

-

+

Z3 ZC3

-S3

+S3

Z4 ZC4

-S4

+S4

Z2 ZC2

-S2

+S2

Z1 ZC1

-S1

+S1

LC

0V

L1

0V

L2

0V

LOOP WIRING

~~

Содержание GENT VSINTM-PCB-UPG

Страница 1: ...Voltage rating 230VAC Rated Frequency 50 60Hz Rated Current 0 7A Manufacture Date XX XX L N P3 P7 DIN RAIL FOR OPTIONAL OCTAL TYPE RELAYS 34440 Mains Interface Board MAINS TERMINAL BLOCK EARTH TO DOOR DOOR BATTERY RESTRAINT FIXING POINT 2 OFF 12V 2 1Ah BATTERIES N E L P3 P4 P5 P6 P2 AC AC P7 Aux P9 Battery P8 FS1 FS2 FS3 FS4 FS5 FS6 S5 PB2 S Z Z S SECTOR ZONE1 PB3 S Z Z S SECTOR ZONE2 PB4 S Z Z S ...

Страница 2: ...efore disconnecting them from their terminal blocks m this will help identify the cables for reconnection to the Replacement Mains Interface Board d Remove 34440 Mains Interface Board from the unit n and discard it safely Programming The Replacement Mains Interface Board is factory configured with all four channels as Sector outputs Use the S4 Interface Programmer kit S4 INTERFACE PROG V1 03 or gr...

Страница 3: ...ould then be tested to site specific requirements g Close the enclosure door and lock it using the key 4188 1005 issue 1_03 11_Replacement Board for 34440 MPI 3 Replacement Mains Interface Board Installation PB1 0C LC 01 L1 02 L2 LOOP LOOP OUT LOOP IN LOOP SPUR PB6 AUX O P External Equipment PB2 PB3 PB4 or PB5 S S SECTOR 1 2 3 or 4 10K EOL W IS Sector Output IS Galvanic isolator 02518 10 PB2 PB3 P...

Страница 4: ...eful life the packaging product and batteries should be disposed of via a suitable recycling centre and in accordance with national or local legislation Do not dispose of with your normal household waste Do not burn WEEE Directive At the end of their useful life the packaging product and batteries should be disposed of via a suitable recycling centre 24V 2 1Ahr BATTERIES PB2 S Z Z S SECTOR ZONE1 P...

Отзывы: