Honeywell GALAXY 16103 Скачать руководство пользователя страница 15

11

0 1

0 1

0 1

0 1

0 1 User 1

User 1

User 1

User 1

User 1 *1234

*1234

*1234

*1234

*1234

User(L2)

User(L2)

User(L2)

User(L2)

User(L2)

The 

A>

 and 

B<

 keys are used to select the user to be edited. Pressing 

ent

 will show the options

for that user, starting with the PIN option. Again, the 

A>

 and 

B<

  keys can be used to move

between the options. Pressing the 

ent 

 key allows the displayed option to be modified. Most

users can only access the PIN option. Only Master users can access the other functions. The
programmable options for each user are listed below:

1 = PIN

This allows a new 4, 5, or 6 digit PIN code to be entered.

2 = Type

This allows the user type to be selected. There are 4 types available to choose from:

0 = Cleaner

Can only set and unset the system

1 = User

Can do all day-to-day operation but cannot override fault conditions

2 = Manager

As per User but can override faults and reset alarms and tampers

3 = Master

As per Manager but can add, remove and alter user codes.

3 = Group(s)

If group choice is enabled, this will allow the groups that the user has access to to be altered.
The numbers shown on the display indicate the groups that the user has access to. Pressing
the appropriate number key toggles the group on or off.

4 = Name

This allows a 6-character label to be assigned to the user, to aid identification when viewing
the event log.

5 = RF Fob

This allows a wireless keyfob to be assigned to the user. The fob serial number is shown in the
bottom row. If a new fob is to be assigned it should be ‘learned’ in as follows:
1.

Press the star (*) key to start the learn process.

2.

Press any button on the keyfob. The display will indicate success.

If a keyfob needs to be deleted, while the serial number is displayed, press the 

B<

 key to

delete the serial number then press 

ent

.

6 = Prox Tag (Mk7 Keyprox Units Only)

NOTE:

For programming prox tags onto a 6160 keyprox, use menu 

5 = RF Fob

, but hold

the tag up in place of steps 1 and 2.

This option allows a prox tag to be entered or deleted. On entering the option, the serial
number of the current tag that is programmed will be displayed. To delete the current tag, press
the 

B<

 key until the serial number is cleared then press 

ent

. To program a new tag, clear any

current serial number then press the 

1

 and 

A>

 keys simultaneously then present the new tag in

front of the prox symbol. The new serial number should appear on the screen. Press the 

ent

 key

to save the new number.

Содержание GALAXY 16103

Страница 1: ...User Guide Galaxy 2 44 Honeywell Security ...

Страница 2: ......

Страница 3: ... 6 Setting and Unsetting Groups 6 Setting and Unsetting Without Group Choice 6 Menu Access 7 Setting and Unsetting With Group Choice 7 Menu 11 Omit Zones 8 Menu 12 Timed Set 8 Menu 13 Part Set 8 Menu 14 Night Set 8 Menu 15 Chime 8 Menu 21 Zone Status 8 Menu 22 View Log 9 Menu 23 Display Version 9 Menu 24 Print 9 Menu 31 Walk Test 10 Menu 32 Output Test 10 Menu 41 Time Date 10 Menu 42 Editing Users...

Страница 4: ...iv ...

Страница 5: ... system configuration in order to continue to provide the best protection whilst maintaining ease of use An alarm system will protect you best only when used correctly Please take the time to read through these instructions carefully in order to get the best from your alarm system and avoid false alarms Remember An alarm system will only protect against intruders if it is Set appropriately Always ...

Страница 6: ...ted wireless keyfob Although all of the above methods of control will allow the user to set and unset the system for day to day operation the keypad is required to reset the system after an alarm or fault condition The keypad is also used to access the menu structure where additional functions can be accessed such as Viewing the event log Programming user codes Temporarily omitting zones from the ...

Страница 7: ...de be changed to something else as soon as possible Choose a PIN code that you can remember easily but would be difficult for an intruder to guess Mk7 LCD Keypad 6160 Keypad Prox tags cards are devices that contain a mi crochip that has a unique serial number This number can be read by holding the tag card in front of a prox reader Prox tags cards will allow you to set and unset the system only Th...

Страница 8: ... PIN code then press A Wireless Keyfob Press ON button Prox Tag Hold the tag in front of the prox symbol for 3 seconds The exit timer will begin and there will be a constant tone Leave by the agreed exit route and close the door When the exit timer expires there will be a 5 second settle period and then two beeps will confirm the completion of setting If you hear a rapid beeping sound the system c...

Страница 9: ... until the fault is rectified However depending on the set up of your system and the level of your user access it may be possible override a fault and proceed with the setting procedure If there are faults present when you try to set via the keypad the following typical display will be shown Fault Override Fault Override Fault Override Fault Override Fault Override 03 Event s 03 Event s 03 Event s...

Страница 10: ...and type in your PIN code and press ent The keypad display will show what has happened The scroll keys A and B should be used to scroll through the message screens If the condition has cleared pressing ent or esc will reset the fault condition A fault condition cannot be reset if it has not cleared or if it has not been viewed by a user If you cannot clear the fault condition yourself always call ...

Страница 11: ... key or they can jump to any specific menu item directly by typing the number of the item An overview of all the accessible functions is shown below Not all users will be able to access all of the functions This will depend on their user type that is set up in menu 42 Table 1 Menu Access The function of each menu item is described in the following pages S SET U UNSET Setting and Unsetting With Gro...

Страница 12: ...15 Chime This menu option allows one or more zones to be put into Chime mode When chime mode is enabled for a zone the internal sounders will beep twice each time the detector on that zone is activated This function can be useful for example in a shop to indicate when a customer has come through the front door Menu 21 Zone Status This menu option is used to show the status of each individual detec...

Страница 13: ...lect which groups to view before entering the log Menu 23 Display Version This menu option simply displays the software version number of the system Menu 24 Print This option allows system settings to be printed if a printer is connected to the system If no printer is connected it has no effect On selecting the option there is a sub menu of 4 options which chose what is to be printed The options a...

Страница 14: ... during repeated activations Press the esc key to end the walk test All walk tested zones will be recorded in the event log Menu 32 Output Test This menu option allows the external bell and strobe to be tested There are two sub options that select between the bell and strobe Select the appropriate device and press ent This will take the user to the status display to show the current condition of t...

Страница 15: ... indicate the groups that the user has access to Pressing the appropriate number key toggles the group on or off 4 Name This allows a 6 character label to be assigned to the user to aid identification when viewing the event log 5 RF Fob This allows a wireless keyfob to be assigned to the user The fob serial number is shown in the bottom row If a new fob is to be assigned it should be learned in as...

Страница 16: ...2 Message type This allows the kind of events that are sent to this mobile number There are 4 options 1 Alarm events Just sends alarm activations 2 Alarm set events Sends alarms and all set unset events 3 Alarm fault Sends all alarm events and fault conditions but not set unset events 4 All events Sends all of the above events as and when they occur Menu 47 Remote Access This menu option allows th...

Страница 17: ...E N O H P E L E T S R U O H E C I F F O S E M I T R E H T O O N T N U O C C A 0 0 O I R E N O Z N O I T C N U F N O I T P I R C S E D E M I H C T I M O T R A P 1 0 0 1 2 0 0 1 3 0 0 1 4 0 0 1 1 0 O I R 1 1 0 1 2 1 0 1 3 1 0 1 4 1 0 1 5 1 0 1 6 1 0 1 7 1 0 1 8 1 0 1 ...

Страница 18: ...14 IU1 0032 Rev 1 Copyright Honeywell Security ...