background image

Disclaimer

Honeywell International Inc. (“HII”) reserves the right to make changes in 
specifications and other information contained in this document without prior 
notice, and the reader should in all cases consult HII to determine whether 
any such changes have been made. The information in this publication does 
not represent a commitment on the part of HII.

HII shall not be liable for technical or editorial errors or omissions contained 
herein; nor for incidental or consequential damages resulting from the fur-
nishing, performance, or use of this material.

This document contains proprietary information that is protected by copy-
right. All rights are reserved. No part of this document may be photocopied, 
reproduced, or translated into another language without the prior written con-
sent of HII.

 

2010-2015

 

Honeywell International Inc.

 

All rights reserved.

Other product names or marks mentioned in this document may be trade-
marks or registered trademarks of other companies and are the property of 
their respective owners.

Web Address: 

www.honeywellaidc.com

Содержание FocusBT AP-010-BT

Страница 1: ...Access Point AP 010BT AP 100BT Quick Start Guide Acc Pt QS Rev D 1 15 ...

Страница 2: ...l the O ring the Access Point will be rated to IP41 instead of IP54 2 Plug the interface cable into the Access Point first and then into the appropriate port on the computer The Page button blinks when the Access Point is first connected to the host 3 Turn on the computer laptop desktop USB Connection Page button ...

Страница 3: ...RS232 Connection Page button RS485 Connection Page button ...

Страница 4: ...e Access Point to establish a connection between the Access Point and the scanner The scanner emits a short beep and flashes the green LED to confirm a connection with the Access Point The Access Point s Page button light turns solid blue Keyboard Wedge Connection Page button ...

Страница 5: ...on remains blue If you have difficulty connecting with your 4820 it may be due to Code XML software in your scanner Scan the following bar code then scan the 4820 Linking bar code These steps may resolve this connection problem Managing Connections Auto Reconnect Mode By default the Access Point is set to Auto Reconnect On so the scanner begins the relink process immediately when a con nection to ...

Страница 6: ...period is one hour Pull the scanner s trigger to power the scanner back up If the scanner was linked to the Access Point when it went to sleep it will re link as long as it is in range If multiple scanners use the same Access Point it is possible to inadvertently unlink a scanner that is in sleep mode that has a dead battery or is in the process of getting a new battery To prevent this from happen...

Страница 7: ...ccess Point will begin beeping 3 short and 1 long beep If you pull the trigger on a scanner that is beeping in response or press the Page button on the Access Point a second time all associ ated scanners will stop beeping LED Dimmer Scan a bar code to set the brightness of your Page button Page button LED Dimmer Off LED Dimmer Low LED Dimmer Bright ...

Страница 8: ...standard defaults disconnects the scanner from the Access Point Scan the Linking bar code to re establish a connection Refer to your User s Guide at www honeywellaidc com for additional information about product defaults Additional Programming The Access Point has all the programming capability of a Cordless Charge Base Refer to Cordless System Operation information in your User s Guide at www hon...

Страница 9: ...Required Safety Labels Label location for item number serial number revision information compli ance and safety information ...

Страница 10: ...Ranges Operating 32 F to 122 F 0 C to 50 C Storage 40 F to 158 F 40 C to 70 C Radio Frequency 2 4 to 2 5 GHz ISM Band Frequency Hopping Bluetooth v 2 1 Range AP 010BT 33 ft 10m typical Range AP 100BT 328 ft 100m typical Data Rate Up to 1MBps Humidity 5 to 95 non condensing Mechanical Drop Operational after 50 drops from 3 28 feet 1 m to concrete Vibration 5G Peak from 22Hz to 300Hz ESD Sensitivity...

Страница 11: ...o radio communications However there is no guar antee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna...

Страница 12: ...device may not cause interference 2 This device must accept any interference including interference that may cause undesired operation Conformité à la règlementation canadienne Cet appareil ISM est conforme à la norme CNR 210 du Canada Son fonctionnement est assujetti aux conditions suivantes 1 Cet appareil ne doit pas causer de brouillage préjudiciable 2 Cet appareil doit pouvoir accepter tout br...

Страница 13: ...lies personal computers etc that is not CE marked and does not comply with the Low Voltage Directive Honeywell Scanning Mobility Product Environmental Information Refer to www honeywellaidc com environmental for the RoHS REACH WEEE information Product Agency Compliance AP 010BT Class II Brazil Product Agency Compliance AP 100BT Class I Patents For patent information please refer to www hsmpats com...

Страница 14: ...s contained herein nor for incidental or consequential damages resulting from the fur nishing performance or use of this material This document contains proprietary information that is protected by copy right All rights are reserved No part of this document may be photocopied reproduced or translated into another language without the prior written con sent of HII 2010 2015 Honeywell International ...

Отзывы: