CHAPTER
2
DocName Variable
1
TROUBLESHOOT THE FLEXDOCK
Ethernet LED Does Not Turn On
Problem
You place a computer in to a cup and the Ethernet LED does not turn on.
Possible Causes and Solutions
The computer may not be fully inserted into the charging cup. Make sure the com-
puter is seated all the way into the cup.
The dock may not be connected to a working Ethernet connection. Check to see if
the LEDs mounted in the FlexDock Ethernet connectors are illuminated, and make
sure you are using a known good cable.
The dock may not be connected to power. Make sure the power supply is connected
to a known good AC power source.
For a CK3, CN3, or CN4 computer, you need to install a software update on the
computer to use it with the DX4 Ethernet dock. For more information, see
CK3, CN3, and CN4 with the DX4 Ethernet Dock
Charge LED Does Not Turn On
Problem
You place a battery into a cup and the Charge LED does not turn on.