Honeywell F500 Скачать руководство пользователя страница 5

F500 WHOLE HOUSE/ LIGHT COMMERCIAL HEPA FILTRATION SYSTEM

5

68-0263-2

Installing HEPA AIRWATCH™ Indicator

Mount the HEPA AIRWATCH™ Indicator next to the 
thermostat or in any other convenient location in the home 
living area. The battery-operated device has no external 
electrical requirements.

1.

Remove the AIRWATCH Indicator from the base:
a. Press the tab on the bottom edge of the base.
b. Pull off the bottom of the front cover.

2.

Position the base on the wall in the desired mounting 
position.

3.

Using the holes in the base as a template, mark the 
locations for the anchors and screws provided.

4.

Drill the holes (3/16 in.) and install the screw anchors 
provided.

5.

Position the base over the holes and install the screws 
to firmly secure the base to the wall.

NOTE:

Jumper is factory-installed on pins 1 and 2 for normal 
usage.

6.

Move the jumper to pins 2 and 3, if desired, for light duty 
filter change intervals as shown in Table 2.

 

7.

Install two AAA alkaline batteries (provided) in the har-
ness on the back of the device.

8.

Observe that the device performs a self-test, beeping 
and flashing the LCD display. 

9.

To start the timers, press and hold the black reset button 
on the bottom of the device for five seconds or until the 
display stops flashing. 

10.

Observe the battery LCD (see Fig.5): 
a. On solidly means the unit is correctly powered. 
a. Flashing indicates the battery requires replacing. 

11.

Observe the AIRWATCH (see Fig. 6): 
a. Beep every ten minutes when an LCD is flashing. 
b. Beeping indicates need to replace the system part 

that corresponds with the flashing LCD. 

NOTES:

When batteries need replacing, replace them 
within 30 seconds of removal to maintain the cor-
rect indicator time. 

After 30 seconds of replacing the batteries, if the 
LCD is blank, remove and install new batteries. 

When replacing other parts, press and hold the 
black button on the bottom of the device to reset 
the timer after replacing the parts.

Fig. 6. HEPA AIRWATCH™ Indicator.

Table 2. Filter Change Intervals.

Filter

Normal (Factory 

Setting)

Light Duty

Carbon odor filter

3 months

4 months

Pleated prefilter

12 months

16 months

HEPA filter 

3 years 

5 years

On/Battery

TM

Odor Filter

Prefilter

HEPA Filter

Whole House HEPA Filtration System

Honeywell.com/yourhome

M20580

Содержание F500

Страница 1: ...ectrical outlet Requires no maintenance except periodic media filter replacement Quick and easy media filter replacement Wall mounted AIRWATCHTM Indicator included provides filter change reminders Three filter system Activated carbon filter for odors High efficiency pleated pre filter extends HEPA fil ter life HEPA filter traps at least 99 97 percent of the 0 3 micron particles that pass through i...

Страница 2: ... is tested and calibrated under closely controlled conditions and some minor differences in performance can be expected if those conditions are changed TRADELINE Models available F500 Whole House Light Commercial HEPA Filtration System includes HEPA filter 2 in pleated prefilter carbon odor filter and motor blower Isolation mounting straps and HEPA AIRWATCH Indicator are also included F500A Standa...

Страница 3: ...0 in duct flanges to easily attach the external ductwork The intake port can be moved to a more convenient location if necessary Simply cut a new 4 in x 10 in hole in the desired loca tion and block off the old hole Reattach the duct flange over the new hole A transition can be used to connect round ducting to the Whole House Light Commercial HEPA System Keep duct sizes as large as possible throug...

Страница 4: ...her ends of the straps to the floor joists with wide head nails or screws not supplied be sure the unit is level 3 Connect the HEPA System to the return air duct See Fig 1 and 2 Seal all duct joints with caulk mastic or high quality foil duct tape Installing Whole House Light Commercial HEPA Filtration System Electrical Connections The F500 has a 3 prong 120 Vac connector plug with ground If furth...

Страница 5: ...ce 8 Observe that the device performs a self test beeping and flashing the LCD display 9 To start the timers press and hold the black reset button on the bottom of the device for five seconds or until the display stops flashing 10 Observe the battery LCD see Fig 5 a On solidly means the unit is correctly powered a Flashing indicates the battery requires replacing 11 Observe the AIRWATCH see Fig 6 ...

Страница 6: ...ion 3 If interconnected to the HVAC system blower turn on the system blower 4 Verify that the Whole House Light Commercial HEPA Air Cleaner turned on TROUBLESHOOTING See Table 3 for troubleshooting guide Table 3 Troubleshooting Guide Symptom Cause Solution Poor airflow Filters plugged Remove and replace filter s Maintain filters at regular intervals Poor power supply at the site Have electrician c...

Страница 7: ... Parts List Illustrated Parts List No Part Number Description 1 32005012 001 HEPA AIRWATCH Indicator 2 32006670 001 Blower Motor Assembly 3 32006026 001 Carbon Odor Filter 4 32006027 001 Pleated Prefilter 5 32006028 001 HEPA Filter 5 M20575 4 3 2 1 On Battery TM Odor Filter Prefilter HEPA Filter Whole House HEPA Filtration System Honeywell com yourhome ...

Страница 8: ...tomation and Control Solutions Honeywell Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 Printed in U S A on recycled paper containing at least 10 post consumer paper fibers ...

Отзывы: