F111 (SERIES 3) IN CEILING MEDIA AIR CLEANER
68-0198—05
6
Fig. 4. Fasten cabinet to a structural support.
IMPORTANT
Do not touch the pleated filter media. Handle only
the filter frame to prevent damage to the filter
media.
10.
Remove CPZ™ sorbent modules (select models) from
their packaging and install one module into each
cavity.
11.
Be sure both catches are turned down and filter rests
firmly on catches.
12.
Install the prefilter in the air cleaner lid. Position the
prefilter so that the Air Flow Direction Arrow is facing
upward when the lid is closed.
Remote 3 Speed Wall Switch
The 190097C Remote Wall Switch Assembly allows control
of the F111 model air cleaners from a a location separate
from the air cleaner. The assembly includes a remote
switch with an outlet box cover, outlet box, extension ring,
and a wire harness. Wiring to connect the remote switch
and air cleaner must be furnished separately.
CAUTION
• This installation to be performed only by a
qualified installer.
• All wiring to comply with local electrical codes.
• Disconnect power to air cleaner at fuse or breaker
before beginning work. Failure to do so can result
in shock hazard endangering equipment and
personal safety of installer.
• Only one air cleaner can be connected to a remote
switch
Fig. 5. Wiring F111 Series 3 Air Cleaner
1.
Disconnect power to air cleaner.
2.
Mount 4” x 4” outlet box at desired remote location.
3.
Attach 3/4” extension ring to outlet box.
4.
Run five conductor, color-coded, 18-gauge wires
from the remote switch location to the air cleaner.
At REMOTE SWITCH:
5.
Use three wire nuts to connect three color-coded,
wires on the remote switch to three color-coded wires
running to the air cleaner. (Red, Blue, Violet)
6.
Use one wire nut to connect white color-coded, wire
running to the air cleaner to the Neutral wire from the
power source/electrical panel. (White)
Fig. 6. Wiring 3-Speed Remote Switch
CHAIN
NOTE:
FASTEN SECURELY TO STRUCTURAL
SUPPORT SYSTEM, I.E. BAR JOIST,
CONCRETE SLAB OR TIMBER FRAMING.
HEX BOLT
LOCK
WASHER
M10892
TOP OF METAL CABINET
EYEBOLT
BOTTOM FLANGE AGAINST
UNDERSIDE OF TEES
JAM NUT
3/8 IN. X 16T
"Z" BRACKET (4)
JAM
NUT
THREADED
ROD
BOTTOM VIEW OF
UNIT WITHOUT
LID ASSEMBLY
CEILING
TEE
OR USING OPTIONAL "Z" BRACKETS
TOP OF METAL CABINET
A100001
BLACK
A100001
BLACK
Содержание F111