- 9 -
Water jet
① Set washing position
-.Move the window face to nozzle
by using pan/tile and save the
position on preset 59.
② Press and button.
(88+ Preset) at Pelco Protocol
- Set the specific position to wash
front window toward the nozzle on
preset 59.
-Run washing and wiping.
4
Check water level in
the tank
periodically.
Operating
[ Do following step to operate water jet function ]
1.
Save the location of nozzle position (washing) on Preset 59
.
* First of all, The NEXPTZ pan/tilt direction should be decided and saved that window glass of camera housing toward nozzle
of water jet on preset 59.
2.
Push The [4+On] button on HTX-5000 Keyboard.
* Push the 88+preset button at Pelco protocol.
Result : 1
) Pan/Tilt’s moving to nozzle position (location Preset 59 )
2) Auto-Stop after Spray water & Wiping ( 3 sec, 6 Wiping )
3) Pan/Tilt’s moving back to the previous position