47
Item Item Name & Description
522
Battery Low Volt Limit
Voltage limit at which the recorder will automatically generate a low voltage alarm if the
battery reading, reads below limit.
Default: 4.30
523
Shutdown Voltage Limit
The voltage level at which “..H.E.L.P..” is displayed on the LCD as an indication that the
battery is about dead and needs to be replaced.
Default: 4.00
528
Clear Alarms via LCD
This item enables the clearing of all active alarms via the MI Logo. During the Display
List Mode, the "E
.E.E.E.E.E.E.E." display will appear after scrolling through all active
alarms. Allow the recorder to time-out (1-minute) at this display to clear the alarms. If
the MI Logo is used to scroll to the next display item in the list the alarms are
not
cleared.
Code
0- No
Default: 1- Yes
530
Display List 1 Item 1
580, Site ID Number
531
Display List 1 Item 2
582, Time
532
Display List 1 Item 3
583, Date
533 Display List 1 Item 4
503, Case Temperature
534
Display List 1 Item 5
521, Battery Voltage Reading
535
Display List 1 Item 6
255, Reserved
536
Live Display Enable
If configured, the recorder will display live P1, P2, and P3 live pressure and temperature
readings as part of the Display List. If enabled, the first live parameter will follow the
last Display List 1 item and prior to the first Display List 2 item. All live parameters
have a 30-minute time-out, instead of the usual 1-minute time-out.
Default: Same as item 576
537
Display List 2 Item 1
631, P1 Maximum
538
Display List 2 Item 2
637 Maximum Pressure Time
539
Display List 2 Item 3
638, Maximum Pressure Date
540
Display List 2 Item 4
632, P1 Minimum
541
Display List 2 Item 5
639, Minimum Pressure Time
542
Display List 2 Item 6
640, Minimum Pressure Date
543 Display List 2 Item 7
651, P1 Interval Low Pressure
544
Display List 2 Item 8
650, P1 Interval High
545
Display List 2 Item 9
649, P1 Interval Average
546
Display List 2 Item 10
255, Reserved
547
Display List 2 Item 11
255, Reserved
548 Display List 2 Item 12
255, Reserved
Содержание ERX
Страница 68: ...68 www honeywell com ...
Страница 69: ...69 ...
Страница 70: ...70 www honeywell com ...
Страница 71: ...71 ...
Страница 72: ...72 www honeywell com ...
Страница 73: ...73 ...
Страница 74: ...74 www honeywell com ...
Страница 75: ...75 ...
Страница 76: ...76 www honeywell com ...
Страница 77: ...77 ...
Страница 78: ...78 www honeywell com ...
Страница 79: ...79 ...
Страница 80: ...80 www honeywell com ...
Страница 81: ...81 ...
Страница 82: ...82 www honeywell com ...
Страница 83: ...83 ...