Honeywell enviracaire 61200 Series Скачать руководство пользователя страница 7

How to Change the Filters...

If the Air Cleaner Does Not Operate...

Storage...

The only three parts requiring any service are the activated carbon 
pre-filter, HEPA filter and the CPZ

TM

cartridge. No tools are needed to

change a filter. Disassemble the unit as shown.

1.

Loosen the carrying handle by turning it counterclockwise. Lift the
lid and protective screen from unit.

2.

Lift HEPA filter and activated carbon pre-filter from the base.
The CPZ

TM

cartridge can be removed separately and replaced 

as needed.

3.

Remove the two plastic clips from the top and bottom of the
activated carbon pre-filter and remove it from the HEPA
filter. Replace either filter as needed.

4.

Wrap the activated carbon pre-filter around the HEPA filter and
secure with plastic clips.

Reassemble your Honeywell air cleaner as described below:

1.

Place the assembled HEPA filter and activated carbon pre-filter 
on the base. Place the CPZ

TM

cartridge into place on the base.

2.

Replace the lid and protective screen.

3.

Reattach the carrying handle and turn it clockwise until
securely tightened.

;;;;

;;;;

;;;;;;;;;

;;;;;;;;;

;;;;;;;;;

;;;;;;;;;

;;;;

;;;;

;;;;

;;;;

;;;

;;;

;;;;;;;

;;;;;;;

;;;;;;;

;;;;;;;

;;;;;;;

;;;;;;;

;;;;;;;

;;;;;;;

;;;;;;;

;;;;;;;

;;;;;;;

;;;;;;;;;

;;;;;;;;;

;;;;;;;;;

;;;;;;;;;

;;;;;;;;;

;;;;;;;;;

;;;;;;;;;

;;;;;;;;;

;

;

Check to make sure that the power cord is correctly connected to the outlet.

Test the outlet with another appliance or lamp.

Check the fuse or circuit breaker. The outlet may be overloaded if other 
appliances are also in use. Determine and correct the cause of  the overload.

The thermal overload protection device on the air cleaner's motor may have
engaged. Turn the air cleaner's motor control to OFF and wait 30 to 45 minutes.
Then, plug it in and turn ON again.

If none of the above procedures restore operation, return your unit to the store in
accordance with store policy, or return the complete unit per the instructions in the
warranty section of this owner's guide. Do not attempt to repair the unit yourself.

If you store your Honeywell air cleaner for more than 30 days, we recommend:

Remove both the primary HEPA filter and the activated carbon pre-filter from the unit.

Discard the pre-filter.

Wrap the HEPA filter and CPZ

TM

sorbent media cartridge in separate air-tight 

plastic bags or plastic wrap. Be sure that the HEPA filter and CPZ

TM

sorbent media

cartridge are totally sealed.

To restore the air cleaner to service, unwrap the HEPA filter and CPZ

TM

sorbent

media cartridge, install a new pre-filter, and reinstall all filters in the air cleaner. See
"How to change the Filters..." section for proper installation.

CAUTION: If the CPZ

TM

sorbent media cartridge is not completely sealed, it will 

continue to adsorb gas phase compounds during storage and may need to be 
replaced when the air cleaner is restored to service.

CAUTION: DISCONNECT FROM POWER SUPPLY BEFORE SERVICING

Содержание enviracaire 61200 Series

Страница 1: ...D AND SAVE THESE INSTRUCTIONS Owner s Guide For Model Series 61200 63200 and 64200 Series Air Cleaners The Science of Clean Air 0 1 2 3 HEPA CPZ TM enviracaire 0 1 2 3 HEPA CPZ TM enviracaire 0 1 2 0 1 2 HEPA CPZ TM enviracaire ...

Страница 2: ...air cleaner in a bathroom laundry area or other damp locations 10 To disconnect the air cleaner first turn speed control to OFF position and remove plug from the outlet 11 The air cleaner must be used in its upright position 12 Do not allow foreign objects to enter ventilation or exhaust opening as this may cause electric shock or damage to the air cleaner Do not block air outlets or intakes 13 Lo...

Страница 3: ...nstructions Carefully remove the plastic bag which protects the CPZTM sorbent media cartridge during shipment Your air cleaner will not operate properly with the plastic bag in place and it may damage the air cleaner The plastic bag may contain small particles and dust caused by vibration of the CPZTM sorbent media cartridge during shipment Use care to avoid soiling clothing carpets and other furn...

Страница 4: ...er operated by moving the speed control knob on the base from the Off 0 position to the high 3 position Allow the unit to operate for a few minutes at high speed then leave the control knob in the high position for faster powerful room cleaning or move the knob to the lower setting for quieter operation 61200 Series The Honeywell 61200 Series air cleaner is a 2 speed air cleaner operated by moving...

Страница 5: ... the unit is operated outdoors for a few minutes See Before Operating Your Air Cleaner For best performance the air outlet slot should not be blocked for at least three feet in all directions Select the proper replacement filter for your Honeywell air cleaner from the chart below Replacement filters may be purchased from the retail store or ordered from the dealer where you purchased the product I...

Страница 6: ...oodworking painting or heavy smoking the useful life of the filter media in your air cleaner may be reduced Whenever the combined air resistance of the activated carbon pre filter and primary HEPA filter becomes excessive due to the amount of contaminants they have captured the air cleaner will begin to audibly pulsate Instead of a steady stream of air rapid puffs of air may be felt at the outlet ...

Страница 7: ...e outlet may be overloaded if other appliances are also in use Determine and correct the cause of the overload The thermal overload protection device on the air cleaner s motor may have engaged Turn the air cleaner s motor control to OFF and wait 30 to 45 minutes Then plug it in and turn ON again If none of the above procedures restore operation return your unit to the store in accordance with sto...

Страница 8: ... in material or workmanship Defective product should be returned immediately to Honeywell C This warranty does not cover damage resulting from unauthorized attempts to repair or from any use not in accordance with this manual D This warranty DOES NOT cover the pre filter HEPA filter or CPZTM sorbent media cartridge except for material or workmanship defects E Return defective product to the follow...

Отзывы: