background image

How to Change the Filters...

The only three parts requiring any service are the activated carbon 
pre-filter, the CPZ™ filter and the HEPA filter. No tools are needed. To
change either filter, disassemble the unit as shown.

1. Loosen the carrying handle by turning it counterclockwise and lift 

filter cage cover from unit.

2. Lift HEPA filter, CPZ™ filter and activated carbon pre-filter from 

the base.

3. Remove the fasteners from the activated carbon pre-filter and

remove 
it from the HEPA filter cartridge.

4. Replace filter(s) as needed, and discard used filters.

5. Wrap the activated carbon pre-filter around the HEPA filter 

cartridge and secure it with the fasteners provided.

Reassemble your 

Honeywell

air cleaner as described below:

1. Place the assembled HEPA filter, CPZ™ filter and the activated

carbon pre-filter on the base.

2. Replace the protective screen and lid.

3. Reattach the carrying handle and turn it clockwise until securely

tightened.

;;;

;;;

;;;;;;;

;;;;;;;

;;;;

;;;;

;;;;

;;;;

;;;

;;;

;;;;;;

;;;;;;

;;;;;;

;;;;;;

;;;;;;

;;;;;;

;;;;;;

;;;;;;

;;;;;;

;;;;;;

;;;;;;

;;;;;;;;;;

;;;;;;;;;;

;;;;;;;;;;

;;;;;;;;;;

;;;;;;;;;;

;;;;;;;;;;

;;;;;;;;;;

;;;;;;;;;;

;;;;;;;;;;

;;;;;;;;;;

;

;

CAUTION: DISCONNECT FROM POWER SUPPLY BEFORE SERVICING

Check to make sure that the power cord is correctly connected to the outlet.

Test the outlet with another appliance or lamp.

Check the fuse or circuit breaker. The outlet may be overloaded if other appliances
are also in use. Determine and correct the cause of sthe overload.

If none of the above procedures restore operation, return your unit to the store or if
the store's return policy does not allow, return the complete unit per the
instructions in the warranty section of this owner's guide.

Do not attempt to repair

the unit yourself.

If the Air Cleaner Does Not Operate...

Содержание enviracaire 41000 Series

Страница 1: ... INSTRUCTIONS Owner s Guide For Air Cleaner Models 41000 42000 43000 and 44000 Series The Science of Clean Air 0 1 2 3 HEPA CPZ TM enviracaire 0 1 2 3 HEPA CPZ TM enviracaire 0 1 2 3 HEPA CPZ TM enviracaire 0 1 2 0 1 2 HEPA CPZ TM enviracaire ...

Страница 2: ...laundry area or other damp location 10 To disconnect the air cleaner first turn speed control to OFF position and remove plug from the outlet 11 The air cleaner must be used in its upright position 12 Do not allow foreign objects to enter ventilation or exhaust opening as this may cause electric shock or damage to the air cleaner Do not block air outlets or intakes 13 Locate air cleaner near power...

Страница 3: ... Sorbent Media Cartridge Protective Screen Activated Carbon Pre filter HEPA Filter Cartridge Base Assembly 0 1 2 0 1 2 HEPA CPZ TM enviracaire 41000 Series The Honeywell 41000 Series air cleaner is a 2 speed air cleaner operated by moving the speed control from the off 0 position to the High 2 position Allow the unit to operate for a few seconds at high speed then leave the control knob in the hig...

Страница 4: ...eaners operated by moving the speed control knob on the base from the Off 0 position to the high 3 position Allow the unit to operate for a few seconds at high speed then leave the control knob in the high position for faster powerful room cleaning or move the knob to a lower setting for quieter operation 0 1 2 3 HEPA CPZ TM enviracaire Replacement Filters Select the proper replacement filter for ...

Страница 5: ...lines every 3 years for light usage 2 years for normal usage and 1 year for heavy usage The CPZ Filter Cartridge should be replaced at least every 6 months Filter life depends upon condition of use Our recommendations regarding filter replacement intervals are intended as guidelines only Life expectancy of any filter media is dependent on the concentration of the contaminants to which the system i...

Страница 6: ...r Honeywell air cleaner as described below 1 Place the assembled HEPA filter CPZ filter and the activated carbon pre filter on the base 2 Replace the protective screen and lid 3 Reattach the carrying handle and turn it clockwise until securely tightened CAUTION DISCONNECT FROM POWER SUPPLY BEFORE SERVICING Check to make sure that the power cord is correctly connected to the outlet Test the outlet ...

Страница 7: ... the unit Discard the pre filter and CPZ filter Wrap the HEPA filter in an air tight plastic bag or plastic wrap Be sure that the filter is totally sealed To restore the air cleaner to service unwrap the HEPA filter install a new activated carbon pre filter and CPZ filter reasemble in the air cleaner See How to Change the Filters section for proper installation Storage ...

Страница 8: ... Honeywell will repair or replace this product if it is found to be defective in material or workmanship Defective product should be returned to the place of purchase in accordance with store policy or to Honeywell C This warranty does not cover damage resulting from unauthorized attempts to repair or from any use not in accordance with this manual D This warranty DOES NOT cover the pre filter CPZ...

Отзывы: