A2 Marking ATEX Directive 

 

a. 

General 

The following information is provided as part of the labeling of the Remote Indicator: 
Name and Address of the manufacturer 
The serial number of the Remote Indicator is located on the Meter Body data-plate. The 
first two digits of the serial number identify the year (12) and the second two digits identify 
the week of the year (23); for example, 1223xxxxxxxx indicates that the product was 
manufactured in 2012, in the 23rd week. 

b. 

Apparatus Marked with Multiple Types of Protection 

The user must determine the type of protection required for installation the equipment. The 
user shall then check the box [ ] adjacent to the type of protection used on the equipment 
certification nameplate. Once a type of protection has been checked on the nameplate, the 
equipment shall not then be reinstalled using any of the other certification types. 

c. 

WARNINGS and Cautions 

Non-Incendive / Non-Sparking (Division 2 and Zone 2 Environments): 
             WARNING – EXPLOSION HAZARD – SUBSTITUTION OF COMPONENTS MAY 
IMPAIR     
             SUITABILITY FOR CLASS I, DIVISION 2 
Intrinsically Safe (Divisions 1, Zone 1 and Zone 2 Environments):  
             WARNING – EXPLOSION HAZARD – SUBSTITUTION OF COMPONENTS MAY 
IMPAIR  
             INTRINSIC SAFETY.  
             WARNING – DO NOT OPEN WHEN AN EXPLOSIVE GAS ATMOSPHERE IS 
PRESENT. 
Explosion-Proof (Division 1 and Zone 1 Environments): 
             WARNING – DO NOT OPEN WHEN AN EXPLOSIVE GAS ATMOSPHERE IS 
PRESENT. 
             WARNING – DO NOT OPEN WHEN ENERGIZED  
             “OPEN CIRCUIT BEFORE REMOVING COVER” 
Flameproof (Division 1 and Zone 1 Environments): 
             WARNING – DO NOT OPEN WHEN ENERGIZED 
General Requirements / Increased Safety (Zone 1): 
 

WARNING – DO NOT OPEN WHEN ENERGIZED 

 

WARNING – OPEN CIRCUIT BEFORE REMOVING COVER 

All Protective Measures: 
WARNING:  FOR CONNECTION IN AMBIENTS ABOVE 60°C USE WIRE RATED 105°C 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

A.3 Conditions of Use” for Ex Equipment”, Hazardous Location Equipment or 
“Schedule of Limitations”:  

 

a. 

Consult the manufacturer for dimensional information on the flameproof 
joints for repair. 

b. 

Painted surface of the RMA 800 series may store electrostatic charge and 
become a source of ignition in applications with a low relative humidity less 
than approximately30% relative humidity where the painted surface is 
relatively free of surface contamination such as dirt, dust or oil.  Cleaning of 
the painted surface should only be done with a damp cloth. 

c. 

The ambient temperature range and applicable temperature class of the 
equipment is as follows: 

                          RMA800 series: T4 for -

20˚C < Ta < 70˚C  

 

d. 

The RMA800 series enclosure contains aluminum and is considered to 
present a potential risk of ignition by impact or friction. Care must be 
considered during installation and use to prevent impact or friction to avoid 
impact. 

e. 

If a charge-generating mechanism is present, the exposed metallic part on 
the enclosure is capable of storing a level of electrostatic charge that could 
become incendive for IIC gases. Therefore, the user/installer shall 
implement precautions to prevent the buildup of electrostatic charge, e.g. 
earthing the metallic part. This is particularly important if the equipment is 
installed in a zone 0 location. 

f. 

On installation, the RMA800 series shall be provided with supply transient 
protection external to the apparatus such that the voltage at the supply 
terminals of the RMA800 series does not exceed 140% of the voltage 
rating of the equipment. However when an RMA805 is connected to a 
SmartRadar FlexLine or to a SmartServo 954 the supply transient 
protection is included in the SmartRadar FlexLine or SmartServo 954. 

 

 

Содержание Enraf FlexLine RMA805

Страница 1: ...red to a Horizontal or Vertical Pipe 2 Figure 3 Two Position FF Terminal Block 2 Documentation To access complete documentation including language variants scan the QR code below using your smart phone device or QR code scanner Go to the APP store for your free Smartphone QR scanner Or you can follow the URL to access the online Tank Storage Documentation The Documentation page will contain direct...

Страница 2: ...ipped wire should be in the insulated portion of the ferrule The ferrule can be also be used on the solid core wire Figure 3 Two Position FF Terminal Block Electrical Wiring The Remote Indicator shall be connected to the Loop and Loop terminals of the FlexLine Gauge Typically these are terminals 24 and 25 See the installation manual of the FlexLine Gauge for more information It is possible that ot...

Страница 3: ...s see table 6 Display Setup LCD Contrast For details see table 5 Device Setup HART Setup Parameters For details see table 4 Information Display Comm Module For details see table 3 Return Return to the Level 1 menu LCD Contrast Return Set Contrast 0 9 Default 5 Adjust the LCD contrast level Press to edit or to select number and to enter Return Return to the Level 1 menu Return Parameters HART Addre...

Страница 4: ...6 CSA C22 2 No 94 M91 CSA C22 2 No 25 2017 CSA C22 2 No 61010 1 2017 CSA C22 2No 157 2016 C22 2 No 213 2017 C22 2 No CSA 60079 0 2015 C22 2 No 60079 1 2016 C22 2 No 60079 11 2014 C22 2 No 60079 15 2016 C22 2 No 60079 31 2015 ANSI ISA12 12 01 2017 ANSI ISA 61010 1 2016 ANSI UL 60079 0 2013 ANSI UL 60079 1 2015 ANSI UL 60079 11 2014 ANSI UL 60079 15 2013 ANSI UL 60079 31 2015 FM 3600 2011 FM 3615 20...

Страница 5: ...IZED WARNING OPEN CIRCUIT BEFORE REMOVING COVER All Protective Measures WARNING FOR CONNECTION IN AMBIENTS ABOVE 60 C USE WIRE RATED 105 C A 3 Conditions of Use for Ex Equipment Hazardous Location Equipment or Schedule of Limitations a Consult the manufacturer for dimensional information on the flameproof joints for repair b Painted surface of the RMA 800 series may store electrostatic charge and ...

Страница 6: ...6 RMA805 Enraf FlexLine Remote Indicator Quick Start Guide A 4 Control Drawing ...

Страница 7: ...Sales Email enraf us honeywell com or TAC hfs tac support honeywell com Web Knowledge Base search engine http bit ly 2N5Vldi WARRANTY REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship Contact your local sales office for warranty information If warranted goods are returned to Honeywell during the period of coverage Honeywell will repair o...

Отзывы: